Behaviour and design of shear connectors in composite slabs at elevated temperatures

2015 ◽  
Vol 115 ◽  
pp. 387-397 ◽  
Author(s):  
Ling-Zhu Chen ◽  
Gianluca Ranzi ◽  
Shou-Chao Jiang ◽  
Faham Tahmasebinia ◽  
Guo-Qiang Li
Metals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 229
Author(s):  
Siva Avudaiappan ◽  
Erick I. Saavedra Flores ◽  
Gerardo Araya-Letelier ◽  
Walter Jonathan Thomas ◽  
Sudharshan N. Raman ◽  
...  

An experimental investigation is performed on various cold-formed profiled sheets to study the connection behavior of composite deck slab actions using bolted shear connectors. Various profiles like dovetailed (or) re-entrant profiles, rectangular profiles and trapezoidal profiles are used in the present investigation. This experimental investigation deals with the evaluation of various parameters such as the ultimate load carrying capacity versus deflection, load versus slip, ductility ratio, strain energy and modes of failure in composite slab specimens with varying profiles. From the test results the performance of dovetailed profiled composite slabs’ resistance is significantly higher than the other two profiled composite deck slabs.


2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
K. N. Lakshmikandhan ◽  
P. Sivakumar ◽  
R. Ravichandran ◽  
S. Arul Jayachandran

The strength of the composite deck slab depends mainly on the longitudinal shear transfer mechanism at the interface between steel and concrete. The bond strength developed by the cement paste is weak and causes premature failure of composite deck slab. This deficiency is effectively overcame by a shear transferring mechanism in the form of mechanical interlock through indentations, embossments, or fastening studs. Development of embossment patterns requires an advanced technology which makes the deck profile expensive. Fastening studs by welding weakens the joint strength and also escalates the cost. The present investigation is attempted to arrive at a better, simple interface mechanism. Three types of mechanical connector schemes are identified and investigated experimentally. All of the three shear connector schemes exhibited full shear interaction with negligible slip. The strength and stiffness of the composite slabs with shear connectors are superior about one and half time compared to these of the conventional reinforced concrete slabs and about twice compared to these of composite slabs without mechanical shear connectors. The scheme2 and scheme3 shear connector mechanisms integrate deck webs and improve strength and stiffness of the deck, which can effectively reduce the cost of formworks and supports efficiently.


2011 ◽  
Vol 8 (1) ◽  
pp. 29-34
Author(s):  
M. Youcef ◽  
M. Mimoune ◽  
F. Mimoune

This paper describes the reliability analysis of shear connection in composite beams with profiled steel sheeting. The profiled steel sheeting had transverse ribs perpendicular to the steel beam. The level of safety of shear connection, and failure modes were determinate. An extensive parametric study was conducted to study the effects on the safety and behaviour of shear connection by changing the profiled steel sheeting geometries, the diameter and height of headed stud, as well as the strength of concrete. We compared the level safety calculated using the American specification, British standard and European code for headed stud shear connectors in composite slabs with profiled steel sheeting perpendicular to the steel beam. It is found that the design overestimated the level safety of shear connection.


2016 ◽  
Vol 20 (1) ◽  
pp. 185-203 ◽  
Author(s):  
S.E.M. Shahabi ◽  
N.H. Ramli Sulong ◽  
M. Shariati ◽  
S.N.R. Shah

2016 ◽  
Vol 20 (10) ◽  
pp. 1451-1465 ◽  
Author(s):  
Shou-Chao Jiang ◽  
Gianluca Ranzi ◽  
Ling-Zhu Chen ◽  
Guo-Qiang Li

This article presents an extensive experimental and numerical study aimed at the evaluation of the thermo-structural response of composite beams with composite slabs. Two full-scale fire tests were carried out on simply supported composite steel-concrete beams with steel sheeting perpendicular and parallel to the steel joist, respectively. Both specimens were observed to fail by developing large displacements. Concrete crushing at the mid-span, debonding of the profiled sheeting and spalling of the fire protection were observed during both tests. A three-dimensional finite element model was developed in ABAQUS, and its accuracy was validated against the experimental measurements collected as part of this study. The model was then used to perform a parametric study to determine the influence of the degree of shear connection, load ratio and design fire rate on the structural response of composite beams at elevated temperatures. These results, together with experimental data available in the literature, were used to evaluate the ability of European guidelines to predict the critical temperature of composite beams. It was shown that predictions from Eurocode 4 were safe and provided conservative estimates for most cases.


Sign in / Sign up

Export Citation Format

Share Document