scholarly journals Determination of rubella virus-specific humoral and cell-mediated immunity in pregnant women with negative or equivocal rubella-specific IgG in routine screening

2019 ◽  
Vol 112 ◽  
pp. 27-33 ◽  
Author(s):  
O. Picone ◽  
E. Bouthry ◽  
Y. Bejaoui-Olhmann ◽  
AG Cordier ◽  
S. Nedellec ◽  
...  
2007 ◽  
Vol 14 (11) ◽  
pp. 1416-1419 ◽  
Author(s):  
Christelle Vauloup-Fellous ◽  
Jessica Ursulet-Diser ◽  
Liliane Grangeot-Keros

ABSTRACT We describe here a rapid and semiautomated method for the determination of rubella virus immunoglobulin G (IgG) avidity with the VIDAS instrument. A total of 153 serum samples from persons with naturally acquired rubella virus infections (n = 98), from vaccinated persons (n = 44), and from patients with autoantibodies (n = 11) were included in this study. The rubella virus-specific IgG avidity assay we developed for the VIDAS instrument was evaluated by comparison with an in-house method. Results obtained with the VIDAS instrument allow considering this method valuable to help confirm or exclude acute primary infection or recent vaccination.


2016 ◽  
Vol 54 (7) ◽  
pp. 1720-1725 ◽  
Author(s):  
Elise Bouthry ◽  
Milena Furione ◽  
Daniela Huzly ◽  
Adaeze Ogee-Nwankwo ◽  
LiJuan Hao ◽  
...  

Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed.


2010 ◽  
Vol 82 (2) ◽  
pp. 335-340 ◽  
Author(s):  
J. Allmendinger ◽  
F. Paradies ◽  
M. Kamprad ◽  
T. Richter ◽  
B. Pustowoit ◽  
...  

1961 ◽  
Vol 38 (4) ◽  
pp. 545-562 ◽  
Author(s):  
L. Kecskés ◽  
F. Mutschler ◽  
I. Glós ◽  
E. Thán ◽  
I. Farkas ◽  
...  

ABSTRACT 1. An indirect paperchromatographic method is described for separating urinary oestrogens; this consists of the following steps: acidic hydrolysis, extraction with ether, dissociation of phenol-fractions with partition between the solvents. Previous purification of phenol fraction with the aid of paperchromatography. The elution of oestrogen containing fractions is followed by acetylation. Oestrogen acetate is isolated by re-chromatography. The chromatogram was developed after hydrolysis of the oestrogens 'in situ' on the paper. The quantity of oestrogens was determined indirectly, by means of an iron-reaction, after the elution of the iron content of the oestrogen spot, which was developed by the Jellinek-reaction. 2. The method described above is satisfactory for determining urinary oestrogen, 17β-oestradiol and oestriol, but could include 16-epioestriol and other oestrogenic metabolites. 3. The sensitivity of the method is 1.3–1.6 μg/24 hours. 4. The quantitative and qualitative determination of urinary oestrogens with the above mentioned method was performed in 50 pregnant and 9 non pregnant women, and also in 2 patients with granulosa cell tumour.


1980 ◽  
Vol 45 (4) ◽  
pp. 1099-1108 ◽  
Author(s):  
Mikuláš Chavko ◽  
Michal Bartík ◽  
Evžen Kasafírek

A polarographic study of the hydrolysis of [8-lysine]vasopressin and some hormonogens of the vasopressin series with the blood serum of women in the last week of pregnancy was studied. The dependence of hydrolysis on pH (pH optimum: 7.4-7.50, substrate concentration (Km 1.2 . 10-5M), pH stability and thermal stability were determined. The rate of hydrolysis of individual vasopressin analogues decreases in the order: [8-lysine]vasopressin > Nα-glycyl-prolyl[8-lysine]-vasopressin > Nα-leucyl-[8-lysine]vasopressin > Nα-alanyl-[8-lysine]vasopressin > Nα-phenyl alanyl-[8-lysine]vasopressin > Nα-diglycyl-[8-lysine]vasopressin > Nα-prolyl-[8-lysine]vasopressin > Nα-triglycyl-[8-lysine]vasopressin > Nα-sarcosyl-glycyl-[8-lysine]vasopressin. The degree of hydrolysis gradually increases to a multiple with the length of the pregnancy in consequence of the presence of oxytocine. However, vasopressin is also hydrolysed to a small extent with the enzymes from the blood sera of non-pregnant women. Under similar analytical conditions oxytocin was not hydrolysed with the sera of non-pregnant women and therefore oxytocin is a more suitable substrate than vasopressin for polarographic determination of serum oxytocinase.


1981 ◽  
Vol 27 (1) ◽  
pp. 149-152 ◽  
Author(s):  
M J Obregon ◽  
A Kurtz ◽  
R Ekins ◽  
G Morreale de Escobar

Abstract We assessed a commercial kit (Corning Medical) for "free" and total thyroxine determination, results being compared to those obtained by the Ekins and Ellis dialysis method (free thyroxine) and the method of Weeke and Orskov (total thyroxine). The kit procedure permits determination of both free and total thyroxine within 4 to 5 h, and the combined results may disclose changes in binding to plasma proteins that would be missed if only free thyroxine were determined. With both free-thyroxine methods, the values distinguished hyperthyroid patients from normal controls and pregnant women with 100% accuracy, but there was some overlap between hypothyroid patients and controls. Absolute values with the kit procedure often exceed those obtained by dialysis, especially for hypothyroid patients and pregnant women. We conclude that the kit may be of as much diagnostic value as the dialysis method if the limitations regarding absolute values are kept in mind and the test is not used as a substitute for thyrotropin determinations in cases of suspected hypothyroidism.


1981 ◽  
Vol 144 (2) ◽  
pp. 137-141 ◽  
Author(s):  
E. Rossier ◽  
P. H. Phipps ◽  
J. M. Weber ◽  
O. H. Meurman

Sign in / Sign up

Export Citation Format

Share Document