Intensive site preparation for reforestation wastes multi-trophic biodiversity potential in commercial oak woodlands

2021 ◽  
Vol 300 ◽  
pp. 113741
Author(s):  
Ondřej Košulič ◽  
Jiří Procházka ◽  
Ivan H. Tuf ◽  
Radek Michalko
Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1147
Author(s):  
Alessio Danilo Inchingolo ◽  
Angelo Michele Inchingolo ◽  
Ioana Roxana Bordea ◽  
Edit Xhajanka ◽  
Donato Mario Romeo ◽  
...  

Many different osteotomy procedures has been proposed in the literature for dental implant site preparation. The osseodensification is a drilling technique that has been proposed to improve the local bone quality and implant stability in poor density alveolar ridges. This technique determines an expansion of the implant site by increasing the density of the adjacent bone. The aim of the present investigation was to evaluate the effectiveness of the osseodensification technique for implant site preparation through a literature review and meta-analysis. The database electronic research was performed on PubMed (Medline) database for the screening of the scientific papers. A total of 16 articles have been identified suitable for the review and qualitative analysis—11 clinical studies (eight on animals, three on human subjects), four literature reviews, and one case report. The meta-analysis was performed to compare the bone-to-implant contact % (BIC), bone area fraction occupied % (BAFO), and insertion torque of clockwise and counter-clockwise osseodensification procedure in animal studies. The included articles reported a significant increase in the insertion torque of the implants positioned through the osseodensification protocol compared to the conventional drilling technique. Advantages of this new technique are important above all when the patient has a strong missing and/or low quantity of bone tissue. The data collected until the drafting of this paper detect an improvement when the osseodensification has been adopted if compared to the conventional technique. A significant difference in BIC and insertion torque between the clockwise and counter-clockwise osseodensification procedure was reported, with no difference in BAFO measurements between the two approaches. The effectiveness of the present study demonstrated that the osseodensification drilling protocol is a useful technique to obtain increased implant insertion torque and bone to implant contact (BIC) in vivo. Further randomized clinical studies are required to confirm these pieces of evidence in human studies.


2019 ◽  
Vol 45 (4) ◽  
pp. 259-266
Author(s):  
Claudio Stacchi ◽  
Matteo De Biasi ◽  
Lucio Torelli ◽  
Massimo Robiony ◽  
Roberto Di Lenarda ◽  
...  

The primary objective of the present in vitro study was to evaluate the influence of implant site preparation technique (drills vs ultrasonic instrumentation) on the primary stability of short dental implants with two different designs inserted in simulated low-quality cancellous bone. Eighty implant sites were prepared in custom-made solid rigid polyurethane blocks with two different low cancellous bone densities (5 or 15 pounds per cubic foot [PCF]), equally distributed between piezoelectric (Surgysonic Moto, Esacrom, Italy) and conventional drilling techniques. Two short implant systems (Prama and Syra, Sweden & Martina) were tested by inserting 40 fixtures of each system (both 6.0 mm length and 5.0 mm diameter), divided in the four subgroups (drills/5 PCF density; drills/15 PCF density; piezo/5 PCF density; piezo/15 PCF density). Insertion torque (Ncm), implant stability quotient values, removal torque (Ncm), and surgical time were recorded. Data were analyzed by 3-way ANOVA and Scheffé's test (α = 0.05). With slight variations among the considered dependent variables, overall high primary implant stability was observed across all subgroups. Piezoelectric instrumentation allowed for comparable or slightly superior primary stability in comparison with the drilling procedures in both implant systems. The Prama implants group showed the highest mean reverse torque and Syra implants the highest implant stability quotient values. Piezoelectric implant site preparation took prolonged operative time compared to conventional preparation with drills; among the drilling procedures, Syra system required fewer surgical steps and shorter operative time.


1998 ◽  
Vol 22 (4) ◽  
pp. 222-226 ◽  
Author(s):  
W. Michael Aust ◽  
James A. Burger ◽  
William H. McKee ◽  
Gregory A. Scheerer ◽  
Mark D. Tippett

Abstract Wet-weather harvesting operations on wet pine fiats can cause soil disturbances that may reduce long-term site productivity. Site preparation and fertilization are often recommended as ameliorative practices for such disturbances, but few studies have actually quantified their effects on restoration. The purposes of this study were to quantify the effects of wet-weather harvest traffic in designated skid trails on soil properties and loblolly pine (Pinus taeda) growth, and to evaluate the ameliorative effects of site preparation. Study sites were established on wet pine flats of the lower Coastal Plain within the Francis Marion National Forest (Berkeley County, SC). Treatments were arranged in a split-split plot within a randomized complete block design. Treatments were two levels of traffic (nontrafficked, trafficked), four levels of mechanical site preparation (none, disking, bedding, disking + bedding), and two levels of fertilization (none, 337 kg /ha of 10-10-10 fertilizer). initially, the trafficking increased soil bulk densities and reduced soil water movement and subsequent growth of loblolly pine (years 1 and 2). Bedding combined with fertilization restored site productivity to non trafficked levels within 4 yr, but disking or fertilization treatments alone were not effective at ameliorating the traffic effects. The effectiveness of the bedding and fertilization treatments for amelioration of traffic effects was probably facilitated by the relatively small area of disturbed skid trails (<10%) found on these sites. Areas having more severe disturbance or higher percentages of disturbance might not be ameliorated as rapidly. South. J. Appl. For. 22(4):222-226.


1997 ◽  
Vol 21 (3) ◽  
pp. 116-122 ◽  
Author(s):  
Thomas A. Waldrop

Abstract Four variations of the fell-and-burn technique, a system developed to produce mixed pine-hardwood stands in the Southern Appalachian Mountains, were compared in the Piedmont region. All variations of this technique successfully improved the commercial value of low-quality hardwood stands by introducing a pine component. After six growing seasons, loblolly pine (Pinus taeda L.) occupied the dominant crown position and oaks the codominant position in fell-and-burn treated stands on poor to medium quality sites. The precise timing of felling residual stems, as prescribed by the fell-and-burn technique, may be flexible because winter and spring felling produced similar results. Although summer site preparation burns reduced hardwood height growth by reducing the length of the first growing season, they did not improve pine survival or growth. Pines were as tall as hardwoods within four growing seasons in burned plots and within six growing seasons in unburned plots. Additional research is needed to determine the level or intensity of site preparation needed to establish pine-hardwood mixtures over a range of site conditions. South. J. Appl. For. 21(3):116-122.


Sign in / Sign up

Export Citation Format

Share Document