Volatile organic compounds in wintertime North China Plain: Insights from measurements of proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS)

Author(s):  
Xianjun He ◽  
Bin Yuan ◽  
Caihong Wu ◽  
Sihang Wang ◽  
Chaomin Wang ◽  
...  
2012 ◽  
Vol 12 (8) ◽  
pp. 20435-20482 ◽  
Author(s):  
J.-H. Park ◽  
A. H. Goldstein ◽  
J. Timkovsky ◽  
S. Fares ◽  
R. Weber ◽  
...  

Abstract. During summer 2010, a proton transfer reaction-time of flight-mass spectrometer (PTR-TOF-MS) and a standard proton transfer reaction mass spectrometer (PTR-MS) were deployed simultaneously for one month in an orange orchard in the Central Valley of California to collect continuous data suitable for eddy covariance (EC) flux calculations. The high time resolution (5 Hz) and high mass resolution (up to 5000 m Δ m−1) data from the PTR-TOF-MS provided the basis for calculating the concentration and flux for a wide range of volatile organic compounds (VOC). Throughout the campaign, 664 mass peaks were detected in mass-to-charge ratios between 10 and 1278. Here we present PTR-TOF-MS EC fluxes of the 27 ion species for which the vertical gradient was simultaneously measured by PTR-MS. These EC flux data were validated through spectral analysis (i.e. co-spectrum, normalized co-spectrum, and ogive). Based on inter-comparison of the two PTR instruments, no significant instrumental biases were found in either mixing ratios or fluxes, and the data showed agreement within 5% on average for methanol and acetone. For the measured biogenic volatile organic compounds (BVOC), the EC fluxes from PTR-TOF-MS were in agreement with the qualitatively inferred flux directions from vertical gradient measurements by PTR-MS. For the 27 selected ion species reported here, the PTR-TOF-MS measured total (24 h) mean net flux of 299 μg C m−2 h−1. The dominant BVOC emissions from this site were monoterpenes (m/z 81.070 + m/z 137.131 + m/z 95.086, 34%, 102 μg C m−2 h−1) and methanol (m/z 33.032, 18%, 72 μg C m−2 h−1). The next largest fluxes were detected at the following masses (attribution in parenthesis): m/z 59.048 (mostly acetone, 12.2%, 36.5 μg C m−2 h−1), m/z 61.027 (mostly acetic acid, 11.9%, 35.7 μg C m−2 h−1), m/z 93.069 (para-cymene + toluene, 4.1%, 12.2 μg C m−2 h−1), m/z 45.033 (acetaldehyde, 3.8%, 11.5 μg C m−2 h−1), m/z 71.048 (methylvinylketone + methacrolein, 2.4%, 7.1 μg C m−2 h−1), and m/z 69.071 (isoprene + 2-methyl-3-butene-2-ol, 1.8%, 5.3 μg C m−2 h−1). Low levels of emission and/or deposition (<1.6% for each, 5.8% in total flux) were observed for the additional reported masses. Overall, our results show that EC flux measurements using PTR-TOF-MS is a powerful new tool for characterizing the biosphere-atmosphere exchange including both emission and deposition for a large range of BVOC and their oxidation products.


2013 ◽  
Vol 13 (3) ◽  
pp. 1439-1456 ◽  
Author(s):  
J.-H. Park ◽  
A. H. Goldstein ◽  
J. Timkovsky ◽  
S. Fares ◽  
R. Weber ◽  
...  

Abstract. During summer 2010, a proton transfer reaction – time of flight – mass spectrometer (PTR-TOF-MS) and a quadrupole proton transfer reaction mass spectrometer (PTR-MS) were deployed simultaneously for one month in an orange orchard in the Central Valley of California to collect continuous data suitable for eddy covariance (EC) flux calculations. The high time resolution (5 Hz) and high mass resolution (up to 5000 m/Δm) data from the PTR-TOF-MS provided the basis for calculating the concentration and flux for a wide range of volatile organic compounds (VOC). Throughout the campaign, 664 mass peaks were detected in mass-to-charge ratios between 10 and 1278. Here we present PTR-TOF-MS EC fluxes of the 27 ion species for which the vertical gradient was simultaneously measured by PTR-MS. These EC flux data were validated through spectral analysis (i.e., co-spectrum, normalized co-spectrum, and ogive). Based on inter-comparison of the two PTR instruments, no significant instrumental biases were found in either mixing ratios or fluxes, and the data showed agreement within 5% on average for methanol and acetone. For the measured biogenic volatile organic compounds (BVOC), the EC fluxes from PTR-TOF-MS were in agreement with the qualitatively inferred flux directions from vertical gradient measurements by PTR-MS. For the 27 selected ion species reported here, the PTR-TOF-MS measured total (24 h) mean net flux of 299 μg C m−2 h−1. The dominant BVOC emissions from this site were monoterpenes (m/z 81.070 + m/z 137.131 + m/z 95.086, 34%, 102 μg C m−2 h−1) and methanol (m/z 33.032, 18%, 72 μg C m−2 h−1). The next largest fluxes were detected at the following masses (attribution in parenthesis): m/z 59.048 (mostly acetone, 12.2%, 36.5 μg C m−2 h−1), m/z 61.027 (mostly acetic acid, 11.9%, 35.7 μg C m−2 h−1), m/z 93.069 (para-cymene + toluene, 4.1%, 12.2 μg C m−2 h−1), m/z 45.033 (acetaldehyde, 3.8%, 11.5 μg C m−2 h−1), m/z 71.048 (methylvinylketone + methacrolein, 2.4%, 7.1 μg C m−2 h−1), and m/z 69.071 (isoprene + 2-methyl-3-butene-2-ol, 1.8%, 5.3 μg C m−2 h−1). Low levels of emission and/or deposition (<1.6% for each, 5.8% in total flux) were observed for the additional reported masses. Overall, our results show that EC flux measurements using PTR-TOF-MS is a powerful new tool for characterizing the biosphere-atmosphere exchange including both emission and deposition for a large range of BVOC and their oxidation products.


Ocean Science ◽  
2019 ◽  
Vol 15 (4) ◽  
pp. 925-940 ◽  
Author(s):  
Charel Wohl ◽  
David Capelle ◽  
Anna Jones ◽  
William T. Sturges ◽  
Philip D. Nightingale ◽  
...  

Abstract. We present a technique that utilises a segmented flow coil equilibrator coupled to a proton-transfer-reaction mass spectrometer to measure a broad range of dissolved volatile organic compounds. Thanks to its relatively large surface area for gas exchange, small internal volume, and smooth headspace–water separation, the equilibrator is highly efficient for gas exchange and has a fast response time (under 1 min). The system allows for both continuous and discrete measurements of volatile organic compounds in seawater due to its low sample water flow (100 cm3 min−1) and the ease of changing sample intake. The equilibrator setup is both relatively inexpensive and compact. Hence, it can be easily reproduced and installed on a variety of oceanic platforms, particularly where space is limited. The internal area of the equilibrator is smooth and unreactive. Thus, the segmented flow coil equilibrator is expected to be less sensitive to biofouling and easier to clean than membrane-based equilibration systems. The equilibrator described here fully equilibrates for gases that are similarly soluble or more soluble than toluene and can easily be modified to fully equilibrate for even less soluble gases. The method has been successfully deployed in the Canadian Arctic. Some example data from underway surface water and Niskin bottle measurements in the sea ice zone are presented to illustrate the efficacy of this measurement system.


Sign in / Sign up

Export Citation Format

Share Document