segmented flow
Recently Published Documents


TOTAL DOCUMENTS

306
(FIVE YEARS 52)

H-INDEX

42
(FIVE YEARS 4)

2021 ◽  
Vol 54 (11) ◽  
pp. 603-611
Author(s):  
Souta Yamasaki ◽  
Ken-Ichiro Sotowa ◽  
Toshihide Horikawa
Keyword(s):  

2021 ◽  
pp. 117040
Author(s):  
Zhengbiao Peng ◽  
Guichao Wang ◽  
Behdad Moghtaderi ◽  
Elham Doroodchi
Keyword(s):  

Chemosensors ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 122
Author(s):  
Aldo Roda ◽  
Pierpaolo Greco ◽  
Patrizia Simoni ◽  
Valentina Marassi ◽  
Giada Moroni ◽  
...  

A simple and versatile continuous air-segmented flow sensor using immobilized luciferase was designed as a general miniaturized platform based on sensitive biochemiluminescence detection. The device uses miniaturized microperistaltic pumps to deliver flows and compact sensitive light imaging detectors based on BI-CMOS (smartphone camera) or CCD technology. The low-cost components and power supply make it suitable as out-lab device at point of need to monitor kinetic-related processes or ex vivo dynamic events. A nylon6 flat spiral carrying immobilized luciferase was placed in front of the detector in lensless mode using a fiber optic tapered faceplate. ATP was measured in samples collected by microdialysis from rat brain with detecting levels as low as 0.4 fmoles. The same immobilized luciferase was also used for the evaluation of bile salt hydrolase (BSH) activity in intestinal microbiota. An aminoluciferin was conjugatated with chenodeoxycholic acid forming the amide derivative aLuc-CDCA. The hydrolysis of the aLuc-CDCA probe by BSH releases free uncaged aminoluciferin which is the active substrate for luciferase leading to light emission. This method can detect as low as 0.5 mM of aLuc-CDCA, so it can be used on real faecal human samples to study BSH activity and its modulation by diseases and drugs.


2021 ◽  
pp. 130226
Author(s):  
Yuhang Chen ◽  
Yaheng Zhang ◽  
Hongwei Zou ◽  
Minglei Li ◽  
Gang Wang ◽  
...  
Keyword(s):  

Fluids ◽  
2021 ◽  
Vol 6 (4) ◽  
pp. 150
Author(s):  
Maksim P. Vasilev ◽  
Rufat Sh. Abiev

This work presents an experimental study of the possibility of intensifying in microfluidic heat exchangers (MFHE) by creating a two-phase segmented flow (gas–liquid). Measurements of convective heat transfer were carried out using an MFHE, consisting of six channels 1 × 1 mm. Experimental studies have shown that segmented flow makes it possible to increase the Nusselt number of a laminar flow in MFHE up to 1.67 and reduce thermal resistance up to 1.7 times compared to single-phase flow. At the same time, it was found that the intensification of heat exchange by a two-phase flow is observed only for the range of the volume fraction of gas from 10 to 30%. In addition, the calculation of the thermal performance criterion, including both thermal and hydraulic parameters (friction factor), also confirmed the promise of using the Taylor segmented flow as a method for single-phase heat transfer intensifying in microchannels.


2021 ◽  
Vol 8 ◽  
Author(s):  
Christine Rees ◽  
Julie Janssens ◽  
Kendall Sherrin ◽  
Peter Hughes ◽  
Stephen Tibben ◽  
...  

Ammonium is a fundamental nutrient for phytoplankton growth in seawater and is a key component of the microbial loop. Ammonium measured in parallel with other nutrients is crucial in understanding the small temporal scale changes in oceanographic ecology. Despite the importance of measuring ammonium at sea, owing to its lability, there is no consensus on the best method. The lack of availability of certified reference materials for ammonium in seawater also makes it difficult to assess the accuracy and reproducibility of ammonium measurements. In this study we present a modified segmented flow analysis method using ortho-phthaldialdehyde (OPA) with fluorescence detection to measure ammonium at sea together with four other macro-nutrients (nitrate, nitrite, silicate and phosphate) in near real time. An in-house ammonium quality control (QC) material was produced to improve the accuracy and repeatability of the measurement at sea. The QC was prepared following two different methods and stored in two types of containers. The suitability of the in-house QC’s as a reference material were assessed onboard the RV Investigator in 2018 during two oceanographic voyages, including one on the repeat SR03 CLIVAR transect. This paper describes the production and assessment of the in-house QC for ammonium in seawater, providing groundwork for creating a short-term stable ammonium reference material for sea going voyages. The uncertainty of this method of ammonium measurement was found to be 0.10 μmol/L at ammonium concentration of 1.0 μmol/L. Results show that preparation of the QC inside a laminar flow cabinet and directly into 10 mL polypropylene sample tubes just prior to the commencement of the voyage improved its stability.


Sign in / Sign up

Export Citation Format

Share Document