Stress Shielding of Ligaments Using Nonabsorbable Suture Augmentation May Influence the Biology of Ligament Healing

Author(s):  
Duc M. Nguyen ◽  
Christopher D. Murawski ◽  
Freddie H. Fu ◽  
Robert A. Kaufmann
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Puripun Jirangkul ◽  
Arkaphat Kosiyatrakul

Abstract Background Modified tension band fixation has become commonly used for transverse patella fractures. The conventional stainless steel wire provides sufficient stability but may be associated with complications. Objective The study aimed to evaluate the effectiveness of a new modified tension band fixation technique for transverse patella fractures using a nonabsorbable suture. Material and methods We present the result of a prospective series using a nonabsorbable suture (FiberWire) for transverse patella fractures. The mean follow-up period totaled 12 months. A total of 16 patients were evaluated by radiographic and clinical review. The postoperative clinical evaluation employed Lysholm and Böstman scores. Result All clinical results on follow-up were good to excellent. Minimal intra-articular joint stepping and further fracture displacement were recorded. No patient needed re-operation, and functional outcomes of the knee were satisfactory. No significant differences were found between the injured and contralateral knee range of motion. No symptomatic implants and skin complications were noted, and all fractures were completed heal within 15 weeks. Conclusion FiberWire provided sufficient stability and reduced postoperative complications. The results proved appropriate, and the technique has merit, as it obviates the need for re-operation.


Micromachines ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 307
Author(s):  
Cheng-Tang Pan ◽  
Che-Hsin Lin ◽  
Ya-Kang Huang ◽  
Jason S. C. Jang ◽  
Hsuan-Kai Lin ◽  
...  

Intervertebral fusion surgery for spinal trauma, degeneration, and deformity correction is a major vertebral reconstruction operation. For most cages, the stiffness of the cage is high enough to cause stress concentration, leading to a stress shielding effect between the vertebral bones and the cages. The stress shielding effect affects the outcome after the reconstruction surgery, easily causing damage and leading to a higher risk of reoperation. A porous structure for the spinal fusion cage can effectively reduce the stiffness to obtain more comparative strength for the surrounding tissue. In this study, an intervertebral cage with a porous gradation structure was designed for Ti64ELI alloy powders bonded by the selective laser melting (SLM) process. The medical imaging software InVesalius and 3D surface reconstruction software Geomagic Studio 12 (Raindrop Geomagic Inc., Morrisville, NC, USA) were utilized to establish the vertebra model, and ANSYS Workbench 16 (Ansys Inc, Canonsburg, PA, USA) simulation software was used to simulate the stress and strain of the motions including vertical body-weighted compression, flexion, extension, lateral bending, and rotation. The intervertebral cage with a hollow cylinder had porosity values of 80–70–60–70–80% (from center to both top side and bottom side) and had porosity values of 60–70–80 (from outside to inside). In addition, according to the contact areas between the vertebras and cages, the shape of the cages can be custom-designed. The cages underwent fatigue tests by following ASTM F2077-17. Then, mechanical property simulations of the cages were conducted for a comparison with the commercially available cages from three companies: Zimmer (Zimmer Biomet Holdings, Inc., Warsaw, IN, USA), Ulrich (Germany), and B. Braun (Germany). The results show that the stress and strain distribution of the cages are consistent with the ones of human bone, and show a uniform stress distribution, which can reduce stress concentration.


Coatings ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 791
Author(s):  
Muzamil Hussain ◽  
Syed Hasan Askari Rizvi ◽  
Naseem Abbas ◽  
Uzair Sajjad ◽  
Muhammad Rizwan Shad ◽  
...  

Titanium, stainless steel, and CoCrMo alloys are the most widely used biomaterials for orthopedic applications. The most common causes of orthopedic implant failure after implantation are infections, inflammatory response, least corrosion resistance, mismatch in elastic modulus, stress shielding, and excessive wear. To address the problems associated with implant materials, different modifications related to design, materials, and surface have been developed. Among the different methods, coating is an effective method to improve the performance of implant materials. In this article, a comprehensive review of recent studies has been carried out to summarize the impact of coating materials on metallic implants. The antibacterial characteristics, biodegradability, biocompatibility, corrosion behavior, and mechanical properties for performance evaluation are briefly summarized. Different effective coating techniques, coating materials, and additives have been summarized. The results are useful to produce the coating with optimized properties.


2011 ◽  
Vol 11 (01) ◽  
pp. 55-72 ◽  
Author(s):  
DESMOND Y. R. CHONG ◽  
ULRICH N. HANSEN ◽  
ANDREW A. AMIS

Aseptic loosening caused by mechanical factors is a recognized failure mode for tibial components of knee prostheses. This parametric study investigated the effects of prosthesis fixation design changes, which included the presence, length and diameter of a central stem, the use of fixation pegs beneath the tray, all-polyethylene versus metal-backed tray, prosthesis material stiffness, and cement mantle thickness. The cancellous bone compressive stresses and bone–cement interfacial shear stresses, plus the reduction of strain energy density in the epiphyseal cancellous bone, an indication of the likelihood of component loosening, and bone resorption secondary to stress shielding, were examined. Design features such as longer stems reduced bone and bone–cement interfacial stresses thus the risk of loosening is potentially minimized, but at the expense of an increased tendency for bone resorption. The conflicting trend suggested that bone quality and fixation stability have to be considered mutually for the optimization of prosthesis designs. By comparing the bone stresses and bone–cement shear stresses to reported fatigue strength, it was noted that fatigue of both the cancellous bone and bone–cement interface could be the driving factor for long-term aseptic loosening for metal-backed tibial trays.


Sign in / Sign up

Export Citation Format

Share Document