A tailored molecular imprinting ratiometric fluorescent sensor based on red/blue carbon dots for ultrasensitive tetracycline detection

2019 ◽  
Vol 72 ◽  
pp. 100-106 ◽  
Author(s):  
Xiqing Liu ◽  
Tao Wang ◽  
Wenjuan Wang ◽  
Zhiping Zhou ◽  
Yongsheng Yan
RSC Advances ◽  
2015 ◽  
Vol 5 (90) ◽  
pp. 74084-74090 ◽  
Author(s):  
Roghayeh Jalili ◽  
Mohammad Amjadi

An eco-friendly molecularly imprinted fluorescent sensor was developed for nifedipine (NIF) based on silane-functionalized carbon dots.


2019 ◽  
Vol 11 (4) ◽  
pp. 490-506 ◽  
Author(s):  
K. Radhakrishnan ◽  
P. Panneerselvam ◽  
M. Marieeswaran

In this work, a green synthetic route was used to create a number of surface passivated fluorescent carbon quantum dots, which are explored as promising sensing probes, via facile one-pot hydrothermal methods.


Author(s):  
Ali Ghafarloo ◽  
Reza Sabzi ◽  
Naser Samadi ◽  
Hamed Hamishehkar

Synthesis of carbon dots (CDs) from natural resources not only enables green synthesis and production of environmentally friendly materials, but also provides a cost-effective probe as a fluorescence nanosensor. The proposed sensor introduces a unique one-pot hydrothermal CDs synthesis from alfalfa leaves, which is promising for sensing hydrochlorothiazide (HCTZ) via inner filter effect (IFE) and resonance Rayleigh scattering (RRS). The as-prepared CDs had wide emission spectra, excitation-dependent emission, high solubility, high stability, and visible fluorescence light with a quantum yield of up to 11%. The absorption of HCTZ overlapped with the excitation spectra of CDs. Therefore, CDs represented excellent quenching due to IFE when HCTZ was gradually added. Furthermore, this fluorescent sensor was successfully used to quantify HCTZ in the linear ranges (0.17-2.50 μg mL-1) with the limit of detection of 0.11 μg mL-1. The sensing system was simple as no surface functionalization was required for CDs, leading to less laborious steps and more cost-effective synthesis. The reaction time was short, i.e., less than 2 min, indicating a simple approach for rapid analysis of HCTZ. By optimizing conditions, successful measurements were carried out on pharmaceutical tablets.


2021 ◽  
Vol 196 ◽  
pp. 109803
Author(s):  
Gengli Huang ◽  
Xueli Luo ◽  
Xie He ◽  
Yong Han ◽  
Haiping Zhao ◽  
...  

2020 ◽  
Vol 12 (20) ◽  
pp. 2551-2554
Author(s):  
Zideng Gao ◽  
Mingyang Liu ◽  
Ke Xu ◽  
Menglei Tang ◽  
Xiaowen Lin ◽  
...  

We prepared carbon dots (CD) co-doped with nitrogen, phosphorous, and sulfur via a facile ultrasound-assisted method; the resultant carbon dots can be used to selectively detect the antibiotic tetracycline by the IFE of a two-way matching strategy.


2020 ◽  
Vol 720 ◽  
pp. 137680 ◽  
Author(s):  
Xin Wang ◽  
Yongli Liu ◽  
Qingxiang Zhou ◽  
Xueying Sheng ◽  
Yi Sun ◽  
...  

2021 ◽  
pp. 130434
Author(s):  
Qiutong Chen ◽  
Sihan Rong ◽  
Yao Cen ◽  
Guanhong Xu ◽  
Zhen Xie ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document