A rapid point-of-care test for dengue virus-1 based on a lateral flow assay with a near-infrared fluorescent dye

2018 ◽  
Vol 456 ◽  
pp. 23-27 ◽  
Author(s):  
Lin Chen ◽  
Huagui Wang ◽  
Tongsheng Guo ◽  
Chaohui Xiao ◽  
Licheng Liu ◽  
...  
2016 ◽  
Vol 6 (1) ◽  
pp. 1600920 ◽  
Author(s):  
Jane Ru Choi ◽  
Kar Wey Yong ◽  
Ruihua Tang ◽  
Yan Gong ◽  
Ting Wen ◽  
...  

The Analyst ◽  
2021 ◽  
Author(s):  
Lisa K. Seiler ◽  
Rebecca Jonczyk ◽  
Patrick Lindner ◽  
Ncog Linh Phung ◽  
Christine S. Falk ◽  
...  

In this work a novel point of care test to detect sIL-2R during acute kidney rejection with high specificity and sensitivity was developed.


2011 ◽  
Vol 5 (11) ◽  
pp. 786-791 ◽  
Author(s):  
Ayman Marei ◽  
Ghada Boghdadi ◽  
Nahla Abdel-Hamed ◽  
Rasha Hessin ◽  
Theresia Abdoel ◽  
...  

Introduction: Brucellosis is a major public health problem in Egypt. The Brucella IgM/IgG lateral flow assay was developed as a point-of-care test for the diagnosis of human brucellosis. The aim of this study was to assess the diagnostic value of the lateral flow assay for use in Egypt. Methodology: Fifty samples of patients who presented with clinical suspicion of brucellosis over a one-year period were collected.  All samples were subjected to the Brucella IgM/IgG lateral flow assay, serum agglutination test (SAT), rose bengal RB Test (RB), 2- mercapteoethanol (2-ME), culture and PCR. SAT, 2- ME, culture and PCR were retested after the end of the treatment. Results: Culture and SAT confirmed the diagnosis of brucellosis in twenty patients.  While 90% of the samples were positive by SAT, only 30% and 85% were positive by culture and PCR respectively. The sensitivity of the lateral flow assay calculated for the Brucella IgM/IgG was 95% and specificity was 97%. Conclusion: These data show that the lateral flow assay is more suitable for diagnosis of brucellosis in Egypt than culture and SAT.  Application of the PCR on serum samples collected during follow-up revealed that the DNA of the pathogen was yet not completely cleared almost 60 days after the start of treatment with doxycycline and ciprofloxacin.


Author(s):  
Carla Eiras

Interleukin-6 (IL-6) is a multifunctional cytokine and high bloodstream levels of which have been associated with severe inflammatory diseases, such as dengue fever, sepsis, various cancers, and visceral leishmaniasis (VL). Rapid tests for the quantification of IL-6 would be of great assistance for the bedside diagnosis and treatment of diseases such as VL. We have developed a lateral flow assay (LFA) for rapid and colorimetric IL-6 detection, consisting of anti-IL-6 antibodies conjugated to gold nanoparticles (AuNPs). The optimal concentration of anti-IL-6 used in the conjugate was determined to be 800.0 μg/mL, based on an aggregation assay using LFA. A linear relationship between IL-6 standard concentration and color intensity was observed after 20 min, with a linear range between 1.25 ng/mL and 9,000 ng/mL. The limit of detection for this method was estimated a t0.38 ng/mL. The concentration of IL-6 in five patients with severe VL was measured using LFA, and the results were consistent with those obtained using the cytometric bead array (CBA) method. A thorough analysis of the LFA membranes’ surface morphology, before and after sample contact, was performed using atomic force microscopy (AFM).The prototype described here is still being tested and improved, but this LFA will undoubtedly be of great help in the clinical quantification of IL-6.


Author(s):  
Carla Eiras

Interleukin-6 (IL-6) is a multifunctional cytokine and high bloodstream levels of which have been associated with severe inflammatory diseases, such as dengue fever, sepsis, various cancers, and visceral leishmaniasis (VL). Rapid tests for the quantification of IL-6 would be of great assistance for the bedside diagnosis and treatment of diseases such as VL. We have developed a lateral flow assay (LFA) for rapid and colorimetric IL-6 detection, consisting of anti-IL-6 antibodies conjugated to gold nanoparticles (AuNPs). The optimal concentration of anti-IL-6 used in the conjugate was determined to be 800.0 μg/mL, based on an aggregation assay using LFA. A linear relationship between IL-6 standard concentration and color intensity was observed after 20 min, with a linear range between 1.25 ng/mL and 9,000 ng/mL. The limit of detection for this method was estimated at a t0.38 ng/mL. The concentration of IL-6 in five patients with severe VL was measured using LFA, and the results were consistent with those obtained using the cytometric bead array (CBA) method. A thorough analysis of the LFA membranes’ surface morphology, before and after sample contact, was performed using atomic force microscopy (AFM). The prototype described here is still being tested and improved, but this LFA will undoubtedly be of great help in the clinical quantification of IL-6.


2020 ◽  
Vol 58 (9) ◽  
Author(s):  
Katharina Ziegler ◽  
Anca Rath ◽  
Christoph Schoerner ◽  
Renate Meyer ◽  
Thomas Bertsch ◽  
...  

ABSTRACT Diagnosis of Lyme neuroborreliosis (LNB) is challenging, as long as Borrelia-specific intrathecal antibodies are not yet detectable. The chemokine CXCL13 is elevated in the cerebrospinal fluid (CSF) of LNB patients. Here, we compared the performances of the Euroimmun CXCL13 enzyme-linked immunosorbent assay (CXCL13 ELISA) and the ReaScan CXCL13 lateral flow immunoassay (CXCL13 LFA), a rapid point-of-care test, to support the diagnosis of LNB. In a dual-center case-control study, CSF samples from 90 patients (34 with definite LNB, 10 with possible LNB, and 46 with other central nervous system [CNS] diseases [non-LNB group]) were analyzed with the CXCL13 ELISA and the CXCL13 LFA. Classification of patients followed the European Federation of Neurological Societies (EFNS) guidelines on LNB. The CXCL13 ELISA detected elevated CXCL13 levels in all patients with definite LNB (median, 1,409 pg/ml) compared to the non-LNB controls (median, 20.7 pg/ml; P < 0.0001), with a sensitivity of 100% and a specificity of 84.8% (cutoff value, 78.6 pg/ml; area under the receiver operating characteristic [ROC] curve, 0.93). Similarly, the CXCL13 LFA yielded elevated CXCL13 levels in 31 patients with definite LNB (median arbitrary value, 223.5) compared to the non-LNB control patients (median arbitrary value, 0; P < 0.0001) and had a sensitivity and specificity of 91.2% and 93.5%, respectively (cutoff arbitrary value, 22.5; area under the ROC curve, 0.94). The correlation between the CXCL13 levels obtained by ELISA and LFA was strong (Spearman correlation coefficient r = 0.89; P < 0.0001). The CXCL13 ELISA and the CXCL13 LFA are comparable diagnostic tools for the detection of CXCL13 in the CSF of patients with definite LNB. The advantage of the CXCL13 LFA is the shorter time to result.


Author(s):  
Paul Deutschmann ◽  
Jutta Pikalo ◽  
Martin Beer ◽  
Sandra Blome

African swine fever (ASF) is one of the most important viral diseases of domestic pigs and wild boar. Apart from endemic cycles in Africa, ASF is now continuously spreading in Europe and Asia. As ASF leads to severe but unspecific clinical signs and high lethality, early pathogen detection is of utmost importance. Recently, “point-of-care” (POC) tests have been intensively discussed for the use in remote areas but also in the context of on-farm epidemiological investigations and wild boar carcass screening. Along these lines, the INGEZIM ASFV CROM Ag lateral flow assay (Eurofins Technologies Ingenasa) promises virus antigen detection under field conditions within minutes. In the present study, we evaluated the performance of the assay with selected high-quality reference blood samples, and also with real field samples from wild boar carcasses in different stages of decay from the ongoing ASF outbreak in Germany. While we observed a sensitivity of roughly 77% in freeze-thawed matrices of close to ideal quality, our approach to simulate field conditions in direct carcass testing without any modification resulted in a drastically reduced sensitivity of only 12.5%. Freeze thawing increased the sensitivity to roughly 44% which mirrored the overall sensitivity of 49% in the total data set of carcass samples. A diagnostic specificity of 100% was observed. However, most of the German ASF cases in wild boar would have been missed using the lateral flow assay (LFA) alone. Therefore, the antigen-specific LFA should not be regarded as a substitute for any OIE listed diagnostic method and has very limited use for carcass testing at the point of care. For optimized LFA antigen tests, the sensitivity with field samples must be significantly increased. An improved sensitivity is seen with freeze-thawed samples, which may indicate problems in the accessibility of ASFV antigen.


Sign in / Sign up

Export Citation Format

Share Document