scholarly journals Impact of superhydrophobicity on the fluid dynamics of a bileaflet mechanical heart valve

Author(s):  
Hoda Hatoum ◽  
Sravanthi Vallabhuneni ◽  
Arun Kumar Kota ◽  
David L. Bark ◽  
Ketul C. Popat ◽  
...  
Author(s):  
M J King ◽  
T David ◽  
J Fisher

The effect of leaflet opening angle on flow through a bileaflet mechanical heart valve has been investigated using computational fluid dynamics (CFD). Steady state, laminar flow for a Newtonian fluid at a Reynolds number of 1500 was used in the two-dimensional model of the valve, ventricle, sinus and aorta. This computational model was verified using one-dimensional laser Doppler velocimetry (LDV). Although marked differences in the flow fields and energy dissipation of the jets downstream of the valve were found between the CFD predictions and the three-dimensional experimental model, both methods showed similar trends in the changes of the flow fields as the leaflet opening angle was altered. As the opening angle increased the area of recirculating fluid downstream of the leaflets, the pressure drop across the valve and the volumetric flow rate through the outer orifice decreased. For opening angles greater than 80° the jet through the outer orifice recombined with the central jet downstream of the leaflet; for an opening angle of 78° the jet through the outer orifice impinged on the aortic wall before recombining with the central jet. This study suggests that the opening angle has a marked effect on the flow downstream of the bileaflet mechanical heart valve and that valves with opening angles greater than 80° are preferable.


ASAIO Journal ◽  
2006 ◽  
Vol 52 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Wei Yin ◽  
Irvin B. Krukenkamp ◽  
Adam E. Saltman ◽  
Glenn Gaudette ◽  
Krishnamurthy Suresh ◽  
...  

1991 ◽  
Vol 14 (12) ◽  
pp. 781-788 ◽  
Author(s):  
T.H. Chiang ◽  
H. Lam ◽  
R. Quijano ◽  
R. Donham ◽  
P. Gilliam ◽  
...  

The effect of contact geometry and component compliance on the magnitude, distribution, and state of various types of stresses on a bileaflet mechanical heart valve prosthesis during valve closure was analyzed using an Edwards-Duromedics™ mitral valve as example. Static and dynamic stresses developing on both the leaflet and pivot ball during valve closure were modeled using finite element analysis (FEA). Uniform contact between the leaflet and housing as well as between the pivot ball and pivot slot can significantly reduce both static and dynamic stresses around the contact area. The level of the dynamic flexural stresses can be an order of magnitude higher than that of the static stresses. When both the radial and axial compliance of the housing are taken into consideration, peak dynamic stress was more than 40% less than that generated through the impact between a moving leaflet and a non-compliant rigid housing.


Author(s):  
C. Hutchison ◽  
P. E. Sullivan ◽  
C. R. Ethier

Each year over 180,000 mechanical heart valves are implanted worldwide, with the bileaflet mechanical heart valve (BiMHV) accounting for approximately 85% of all valve replacements [1,2]. Although much improved from previous valve designs, aortic BiMHV design is far from ideal, and serious complications such as thromboembolism and hemolysis often result. Hemolysis and platelet activation are thought to be caused by turbulent Reynolds shear stresses in the flow [1]. Numerous previous studies have examined aortic BiMHV flow using LDA and two component Particle Image Velocimetry (PIV), and have shown the flow to be complex and three-dimensional [3,4]. Stereoscopic PIV (SPIV) can obtain all three velocity components on a flow plane, and hence has the potential to provide better understanding of three dimensional flow characteristics. The objective of the current study was to use SPIV to measure steady flow, including turbulence properties, downstream of a BiMHV in a modeled aorta. The resulting dataset will be useful for CFD model validation, and the intent is to make it publicly available.


Sign in / Sign up

Export Citation Format

Share Document