Formation of silicon-calcium-phosphate-containing coating on Mg-Zn-Ca alloy by a two-step micro-arc oxidation technique

2018 ◽  
Vol 212 ◽  
pp. 37-40 ◽  
Author(s):  
Jinhe Dou ◽  
Chunyan Wang ◽  
Guochao Gu ◽  
Chuanzhong Chen
Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3693
Author(s):  
Yurii P. Sharkeev ◽  
Ekaterina G. Komarova ◽  
Valentina V. Chebodaeva ◽  
Mariya B. Sedelnikova ◽  
Aleksandr M. Zakharenko ◽  
...  

A modern trend in traumatology, orthopedics, and implantology is the development of materials and coatings with an amorphous–crystalline structure that exhibits excellent biocopatibility. The structure and physico–chemical and biological properties of calcium phosphate (CaP) coatings deposited on Ti plates using the micro-arc oxidation (MAO) method under different voltages (200, 250, and 300 V) were studied. Amorphous, nanocrystalline, and microcrystalline statesof CaHPO4 and β-Ca2P2O7were observed in the coatings using TEM and XRD. The increase in MAO voltage resulted in augmentation of the surface roughness Ra from 2.5 to 6.5 µm, mass from 10 to 25 mg, thickness from 50 to 105 µm, and Ca/P ratio from 0.3 to 0.6. The electrical potential (EP) of the CaP coatings changed from −456 to −535 mV, while the zeta potential (ZP) decreased from −53 to −40 mV following an increase in the values of the MAO voltage. Numerous correlations of physical and chemical indices of CaP coatings were estimated. A decrease in the ZP magnitudes of CaP coatings deposited at 200–250 V was strongly associated with elevated hTERT expression in tumor-derived Jurkat T cells preliminarily activated with anti-CD2/CD3/CD28 antibodies and then contacted in vitro with CaP-coated samples for 14 days. In turn, in vitro survival of CD4+ subsets was enhanced, with proinflammatory cytokine secretion of activated Jurkat T cells. Thus, the applied MAO voltage allowed the regulation of the physicochemical properties of amorphous–crystalline CaP-coatings on Ti substrates to a certain extent. This method may be used as a technological mechanism to trigger the behavior of cells through contact with micro-arc CaP coatings. The possible role of negative ZP and Ca2+ as effectors of the biological effects of amorphous–crystalline CaP coatings is discussed. Micro-arc CaP coatings should be carefully tested to determine their suitability for use in patients with chronic lymphoid malignancies.


2008 ◽  
Vol 368-372 ◽  
pp. 1194-1197 ◽  
Author(s):  
Chen Ma ◽  
Ying Hui Wang ◽  
Mu Qin Li ◽  
Li Jie Qu

Rare earth/calcium phosphate composite coatings were fabricated on the surface of Ti-6Al-4V by micro-arc oxidation (MAO) technique. The wear properties and corrosion resistant of rare earth/ calcium phosphate composite coatings in the simulated body fluid (SBF) have been investigated and the bioactivity of the composite coatings were evaluated. The results show that the friction coefficient of the composite coatings in the SBF is only 0.15~0.18 and the anode polarization potential of the coating has been obviously enhanced about 0.18V compared with that of coatings of calcium phosphate coatings. So the composite coatings have excellent wear and corrosion resistant properties. XRD analysis indicates that the composite coatings can induce hydroxyapatite to form on its surface after soaked in SBF for 9d, which shows that the composite coatings own good bioactivity.


2007 ◽  
Vol 330-332 ◽  
pp. 629-632 ◽  
Author(s):  
Kai Hui Nan ◽  
G.X. Pei

Titanium oxide films were obtained by MAO at the applied voltages of 250-550V and their bio-mineralization behavior was investigated. The films were composed mainly of TiO2 phases in the form of anatase and rutile and enriched with Ca and P elements in the form of CaTiO3 and amorphous calcium phosphate. Their bio-mineralization behavior was evaluated in a simulated body fluid (SBF). After immersed in SBF for 72 h, white mineralized layers were observed on the samples obtained at high voltages. The bio-mineralized rate of samples increased with the applied voltages, which resulted in the difference on morphology of different samples. The structure and composition of the films have an important effect on their bio-mineralization behavior.


2013 ◽  
Vol 142 (1) ◽  
pp. 87-94 ◽  
Author(s):  
A. Seyfoori ◽  
Sh. Mirdamadi ◽  
Z.S. Seyedraoufi ◽  
A. Khavandi ◽  
M. Aliofkhazraei

2016 ◽  
Vol 164 ◽  
pp. 575-578 ◽  
Author(s):  
Jinhe Dou ◽  
Huijun Yu ◽  
Chuanzhong Chen ◽  
Yaokun Pan ◽  
Dandan Gao ◽  
...  

2013 ◽  
Vol 690-693 ◽  
pp. 1465-1468 ◽  
Author(s):  
Shu Jing Dong ◽  
Jun Hua Bao ◽  
Shu Juan Sun

To obtain optimal medical ceramic film with bioactivity, Microarc oxidized TiO2-based films containing Ca and P on titanium alloy were formed in electrolytes containing hydroxyapatite and β-tricalcium phosphate salts. After that the biocompatibility tests including invitro soaking test and invivo implant experiment were carried out, and component and phases of films were analysed by energy dispersive spectrometer and X-ray diffraction, respectively.The obtained result shows the porosity biomedical ceramic films with different proportional of Hydroxyapatite/β-tricalcium are fabricated through changing the electrolyte composions,respectively.The bioactivity of biphasic calcium phosphate is enhanced comparing to the pure HA ones.So the biphasic calcium phosphate film material can be satified with medical application.


Sign in / Sign up

Export Citation Format

Share Document