Experimental Investigation on the Usage of Steel Fibres and Carbon Fibre Mesh at Plastic Hinge Length of Slab

2019 ◽  
Vol 14 ◽  
pp. 248-256
Author(s):  
S.Pradeep ◽  
V.U.Eezha Vengai ◽  
D.Florence More
Author(s):  
Xiaowei Cheng ◽  
Haoyou Zhang

AbstractUnder strong earthquakes, reinforced concrete (RC) walls in high-rise buildings, particularly in wall piers that form part of a coupled or core wall system, may experience coupled axial tension–flexure loading. In this study, a detailed finite element model was developed in VecTor2 to provide an effective tool for the further investigation of the seismic behaviour of RC walls subjected to axial tension and cyclic lateral loading. The model was verified using experimental data from recent RC wall tests under axial tension and cyclic lateral loading, and results showed that the model can accurately capture the overall response of RC walls. Additional analyses were conducted using the developed model to investigate the effect of key design parameters on the peak strength, ultimate deformation capacity and plastic hinge length of RC walls under axial tension and cyclic lateral loading. On the basis of the analysis results, useful information were provided when designing or assessing the seismic behaviour of RC slender walls under coupled axial tension–flexure loading.


2017 ◽  
Vol 21 ◽  
pp. 45-49
Author(s):  
Mehmet Kamanli ◽  
Alptug Unal

In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.


2003 ◽  
Vol 8 (5) ◽  
pp. 513-521 ◽  
Author(s):  
R Inai ◽  
E C Chirwa ◽  
H Saito ◽  
T Uozumi ◽  
A Nakai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document