Flexural performance of textile reinforced mortar on reinforced concrete beams

Author(s):  
G. Rajeswari ◽  
G. Palani Selvan ◽  
I. Jaambavi ◽  
J. Esther Baby
2020 ◽  
Vol 38 (5A) ◽  
pp. 669-680
Author(s):  
Ghazwan K. Mohammed ◽  
Kaiss F. Sarsam ◽  
Ikbal N. Gorgis

The study deals with the effect of using Slurry infiltrated fiber concrete (SIFCON) with the reinforced concrete beams to explore its enhancement to the flexural capacity. The experimental work consists of the casting of six beams, two beams were fully cast by conventional concrete (CC) and SIFCON, as references. While the remaining was made by contributing a layer of SIFCON diverse in-depth and position, towards complete the overall depths of the built-up beam with conventional concrete CC. Also, an investigation was done through the control specimens testing about the mechanical properties of SIFCON. The results showed a stiffer behavior with a significant increase in load-carrying capacity when SIFCON used in tension zones. Otherwise high ductility and energy dissipation appeared when SIFCON placed in compression zones with a slight increment in ultimate load. The high volumetric ratio of steel fibers enabled SIFCON to magnificent tensile properties.


Structures ◽  
2022 ◽  
Vol 35 ◽  
pp. 55-67
Author(s):  
Omar Khalid Ali ◽  
Abdulkader Ismail Al-Hadithi ◽  
Ahmed Tareq Noaman

2018 ◽  
Vol 176 ◽  
pp. 593-607 ◽  
Author(s):  
Sindy Seara-Paz ◽  
Belén González-Fonteboa ◽  
Fernando Martínez-Abella ◽  
Diego Carro-López

Structures ◽  
2019 ◽  
Vol 19 ◽  
pp. 394-410 ◽  
Author(s):  
Mohammed Haloob Al-Majidi ◽  
Andreas P. Lampropoulos ◽  
Andrew B. Cundy ◽  
Ourania T. Tsioulou ◽  
Salam Alrekabi

Materials ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 234 ◽  
Author(s):  
Yingwu Zhou ◽  
Yaowei Zheng ◽  
Lili Sui ◽  
Biao Hu ◽  
Xiaoxu Huang

Steel corrosion is considered as the main factor for the insufficient durability of concrete structures, especially in the marine environment. In this paper, to further inhibit steel corrosion in a high chloride environment and take advantage of the dual-functional carbon fiber reinforced polymer (CFRP), the impressed current cathodic protection (ICCP) technique was applied to the hybrid-reinforced concrete beam with internally embedded CFRP bars and steel fiber reinforced polymer composite bar (SFCB) as the anode material while the steel bar was compelled to the cathode. The effect of the new ICCP system on the flexural performance of the hybrid-reinforced concrete beam subjected to corrosion was verified experimentally. First, the electricity-accelerated precorrosion test was performed for the steel bar in the hybrid-reinforced beams with a target corrosion ratio of 5%. Then, the dry–wet cycles corrosion was conducted and the ICCP system was activated simultaneously for the hybrid-reinforced concrete beam for 180 days. Finally, the three-point bending experiment was carried out for the hybrid-reinforced concrete beams. The steel bars were taken out from the concrete to quantitatively measure the corrosion ratio after flexural tests. Results showed that the further corrosion of steel bars could be inhibited effectively by the ICCP treatment with the CFRP bar and the SFCB as the anode. Additionally, the ICCP system showed an obvious effect on the flexural behavior of the hybrid-reinforced concrete beams: The crack load and ultimate load, as well as the stiffness, were enhanced notably compared with the beam without ICCP treatment. Compared with the SFCB anode, the ICCP system with the CFRP bar as the anode material was more effective for the hybrid-reinforced concrete beam to prevent the steel corrosion.


2012 ◽  
Vol 94 (5) ◽  
pp. 1616-1625 ◽  
Author(s):  
Ilker Fatih Kara ◽  
Ashraf F. Ashour

Sign in / Sign up

Export Citation Format

Share Document