Ion beam induced cubic to monoclinic phase transformation of nanocrystalline yttria

Author(s):  
N.J. Shivaramu ◽  
B.N. Lakshminarasappa ◽  
K.R. Nagabhushana ◽  
Fouran Singh
1992 ◽  
Vol 7 (11) ◽  
pp. 3065-3071 ◽  
Author(s):  
Peir-Yung Chu ◽  
Isabelle Campion ◽  
Relva C. Buchanan

Phase transformation and preferred orientation in ZrO2 thin films, deposited on Si(111) and Si(100) substrates, and prepared by heat treatment from carboxylate solution precursors were investigated. The deposited films were amorphous below 450 °C, transforming gradually to the tetragonal and monoclinic phases on heating. The monoclinic phase developed from the tetragonal phase displacively, and exhibited a strong (111) preferred orientation at temperature as low as 550 °C. The degree of preferred orientation and the tetragonal-to-monoclinic phase transformation were controlled by heating rate, soak temperature, and time. Interfacial diffusion into the film from the Si substrate was negligible at 700 °C and became significant only at 900 °C, but for films thicker than 0.5 μm, overall preferred orientation exceeded 90%.


Vacuum ◽  
2021 ◽  
Vol 187 ◽  
pp. 110154
Author(s):  
Shijian Zhang ◽  
Xiao Yu ◽  
Jie Zhang ◽  
Jie Shen ◽  
Haowen Zhong ◽  
...  

Ceramics ◽  
2019 ◽  
Vol 2 (4) ◽  
pp. 568-577 ◽  
Author(s):  
Frigan ◽  
Chevalier ◽  
Zhang ◽  
Spies

The market share of zirconia (ZrO2) dental implants is steadily increasing. This material comprises a polymorphous character with three temperature-dependent crystalline structures, namely monoclinic (m), tetragonal (t) and cubic (c) phases. Special attention is given to the tetragonal phase when maintained in a metastable state at room temperature. Metastable tetragonal grains allow for the beneficial phenomenon of Phase Transformation Toughening (PTT), resulting in a high fracture resistance, but may lead to an undesired surface transformation to the monoclinic phase in a humid environment (low-temperature degradation, LTD, often referred to as ‘ageing’). Today, the clinical safety of zirconia dental implants by means of long-term stability is being addressed by two international ISO standards. These standards impose different experimental setups concerning the dynamic fatigue resistance of the final product (ISO 14801) or the ageing behavior of a standardized sample (ISO 13356) separately. However, when evaluating zirconia dental implants pre-clinically, oral environmental conditions should be simulated to the extent possible by combining a hydrothermal treatment and dynamic fatigue. For failure analysis, phase transformation might be quantified by non-destructive techniques, such as X-Ray Diffraction (XRD) or Raman spectroscopy, whereas Scanning Electron Microscopy (SEM) of cross-sections or Focused Ion Beam (FIB) sections might be used for visualization of the monoclinic layer growth in depth. Finally, a minimum load should be defined for static loading to fracture. The purpose of this communication is to contribute to the current discussion on how to optimize the aforementioned standards in order to guarantee clinical safety for the patients.


2007 ◽  
Vol 46 (15) ◽  
pp. 6164-6169 ◽  
Author(s):  
Qixun Guo ◽  
Yusheng Zhao ◽  
Chao Jiang ◽  
Wendy L. Mao ◽  
Zhongwu Wang ◽  
...  

2022 ◽  
Author(s):  
CY Zhang ◽  
C Agingu ◽  
H Yang ◽  
H Cheng ◽  
H Yu

SUMMARY Objectives: This study aimed to investigate the effects of hydrothermal treatment on four types of monolithic, translucent, yttria-stabilized, tetragonal zirconia polycrystals (Y-TZPs). Methods and Materials: Two commercially available Y-TZP brands—SuperfectZir High Translucency (Aidite Technology Co, China) and Katana HT (Kuraray Noritake Dental, Japan) were assessed. For each brand of Y-TZP, materials of four coloring types, including noncolored (NC), colored by staining (CS), precolored (PC), and multilayered (ML) specimens were investigated after hydrothermal aging in an autoclave at 134°C/0.2 MPa for 0 (control group), 5, 10, and 20 hours. The tetragonal-to-monoclinic phase transformation, surface roughness, flexural strength, and structural reliability (Weibull analysis) were measured and statistically analyzed (α=0.05). The subsurface microstructure was analyzed with scanning electron microscopy. Results: The group ML exhibited the lowest flexural strength and Weibull characteristic strength among the four coloring types (p<0.05). Slight increases in the monoclinic phase volume, flexural strength, and Weibull characteristic strength were observed after hydrothermal aging (pall<0.05). Regardless of coloring type, no significant effects of aging on the Weibull modulus or surface roughness were found for the tested materials. Compared with the Katana HT cross-sections, the SuperfectZir High Translucency cross-sections exhibited a similar but thicker transformation zone. Conclusions: The coloring procedure and material type were found to affect the mechanical properties and aging resistance of translucent monolithic Y-TZP ceramics. Regardless of the aging time, the surface roughness of the tested Y-TZP ceramics remained unchanged.


1994 ◽  
pp. 491-494 ◽  
Author(s):  
H. Tsubakino ◽  
A. Yamamoto ◽  
T. Fujiwara ◽  
K. Sonoda

Author(s):  
Hong Shen ◽  
Juan Jiang ◽  
Decai Feng ◽  
Chen Xing ◽  
Xiaofeng Zhao ◽  
...  

The crack behaviors of yttrium-stabilized zirconia during laser drilling in air, vacuum, and water environments were investigated. Due to the high stress and low fracture toughness induced by tetragonal-monoclinic phase transformation, tremendous cracks occur during drilling in air. Contrastly, cracks were reduced in vacuum drilling since the phase transformation was suppressed due to the generation of oxygen vacancies. By protection of water, no cracks were observed due to low stress and maintained fracture toughness. The crack mechanisms in different drilling media were discussed.


Sign in / Sign up

Export Citation Format

Share Document