High temperature fiber sensor based on spherical-shape structures with high sensitivity

2014 ◽  
Vol 332 ◽  
pp. 154-157 ◽  
Author(s):  
Shuo Yuan ◽  
Zhengrong Tong ◽  
Junfa Zhao ◽  
Weihua Zhang ◽  
Ye Cao
2008 ◽  
Vol 16 (15) ◽  
pp. 11369 ◽  
Author(s):  
Linh Viet Nguyen ◽  
Dusun Hwang ◽  
Sucbei Moon ◽  
Dae Seung Moon ◽  
Youngjoo Chung

2007 ◽  
Vol 26-28 ◽  
pp. 367-371
Author(s):  
Hong Zhen Guo ◽  
Zhang Long Zhao ◽  
Bin Wang ◽  
Ze Kun Yao ◽  
Ying Ying Liu

In this paper the effect of isothermal forging process parameters on the microstructure and the mechanical properties of TA15 titanium alloy was researched. The results of the tests indicate that, in the range of temperature of 850 °C~980 °C and deformation degree of 20%~60%, with the increase of temperature or deformation, as the reinforcement of deformation recrystallization, the primary α-phase tends to the spherical shape and secondary α-phase transforms from the acicular shape to fine and spherical shape with disperse distribution, which enhance the tensile properties at room and high temperature. With the increment of forging times, the spheroidization of primary α-phase aggrandizes and secondary α-phase transforms from spherical and acicular shape to wide strip shape, which decrease the tensile properties at room and high temperature. The preferable isothermal forging process parameters are temperature of 980 °C, deformation degree of 60%, and few forging times.


2017 ◽  
Vol 25 (26) ◽  
pp. 32591 ◽  
Author(s):  
Victor Lambin Iezzi ◽  
Sebastien Loranger ◽  
Raman Kashyap

Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1028
Author(s):  
Na Zhao ◽  
Qijing Lin ◽  
Kun Yao ◽  
Fuzheng Zhang ◽  
Bian Tian ◽  
...  

The optical fiber temperature and refractive index sensor combined with the hollow needle structure for medical treatment can promote the standardization of traditional acupuncture techniques and improve the accuracy of body fluid analysis. A double-parameter sensor based on fiber Bragg grating (FBG) is developed in this paper. The sensor materials are selected through X-ray diffraction (XRD) analysis, and the sensor sensing principle is theoretically analyzed and simulated. Through femtosecond laser writing pure silica fiber, a high temperature resistant wavelength type FBG temperature sensor is obtained, and the FBG is corroded by hydrofluoric acid (HF) to realize a high-sensitivity intensity-type refractive index sensor. Because the light has dual characteristics of energy and wavelength, the sensor can realize simultaneous dual-parameter sensing. The light from the lead-in optical fiber is transmitted to the sensor and affected by temperature and refractive-index; then, the reflection peak is reflected back to the lead-out fiber by the FBG. The high temperature response and the refractive index response of the sensor were measured in the laboratory, and the high temperature characteristics of the sensor were verified in the accredited institute. It is demonstrated that the proposed sensor can achieve temperature sensing up to 1150 °C with the sensitivity of 0.0134 nm/°C, and refractive sensing over a refractive range of 1.333 to 1.4027 with the sensitivity of −49.044 dBm/RIU. The sensor features the advantages of two-parameter measurement, compact structure, and wide temperature range, and it exhibits great potential in acupuncture treatment.


2010 ◽  
Vol 2010 (HITEC) ◽  
pp. 000359-000366 ◽  
Author(s):  
Patrick McCluskey ◽  
Chandradip Patel ◽  
David Lemus

Elevated temperatures can significantly affect the performance and reliability of MEMS gyroscope sensors. A MEMS vibrating resonant gyroscope measures angular velocity via a displacement measurement which can be on the order on nanometers. High sensitivity to small changes in displacement causes the MEMS Gyroscope sensor to be strongly affected by changes in temperature which can affect the displacement of the sensor due to thermal expansion and thermomechanical stresses. Analyzing the effect of temperature on MEMS gyroscope sensor measurements is essential in mission critical high temperature applications, such as inertial tracking of the movement of a fire fighter in a smoke filled indoor environment where GPS tracking is not possible. In this paper, we will discuss the development of the high temperature package for the tracking application, including the characterization of the temperature effects on the performance of a MEMS gyroscope. Both stationary and rotary tests were performed at room and at elevated temperatures on 10 individual single axis MEMS gyroscope sensors.


2021 ◽  
Vol 853 ◽  
pp. 156749
Author(s):  
Ting Liu ◽  
Xuan Chen ◽  
Huimin Zhang ◽  
Aimin Chang ◽  
Yiquan Wu

Sign in / Sign up

Export Citation Format

Share Document