scholarly journals Automatic assessment of the ergonomic risk for manual manufacturing and assembly activities through optical motion capture technology

Procedia CIRP ◽  
2018 ◽  
Vol 72 ◽  
pp. 81-86 ◽  
Author(s):  
Marco Bortolini ◽  
Mauro Gamberi ◽  
Francesco Pilati ◽  
Alberto Regattieri
Author(s):  
Muhamad Nurul Hisyam Yunus ◽  
Mohd Hafiidz Jaafar ◽  
Ahmad Sufril Azlan Mohamed ◽  
Nur Zaidi Azraai ◽  
Md. Sohrab Hossain

Work-related musculoskeletal disorders (WMSDs) are among the most common disorders in any work sector and industry. Ergonomic risk assessment can reduce the risk of WMSDs. Motion capture that can provide accurate and real-time quantitative data has been widely used as a tool for ergonomic risk assessment. However, most ergonomic risk assessments that use motion capture still depend on the traditional ergonomic risk assessment method, focusing on qualitative data. Therefore, this article aims to provide a view on the ergonomic risk assessment and apply current motion capture technology to understand classical mechanics of physics that include velocity, acceleration, force, and momentum in ergonomic risk assessment. This review suggests that using motion capture technologies with kinetic and kinematic variables, such as velocity, acceleration, and force, can help avoid inconsistency and develop more reliable results in ergonomic risk assessment. Most studies related to the physical measurement conducted with motion capture prefer to use non-optical motion capture because it is a low-cost system and simple experimental setup. However, the present review reveals that optical motion capture can provide more accurate data.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3145
Author(s):  
Jan P. Vox ◽  
Anika Weber ◽  
Karen Insa Wolf ◽  
Krzysztof Izdebski ◽  
Thomas Schüler ◽  
...  

The reproduction and simulation of workplaces, and the analysis of body postures during work processes, are parts of ergonomic risk assessments. A commercial virtual reality (VR) system offers the possibility to model complex work scenarios as virtual mock-ups and to evaluate their ergonomic designs by analyzing motion behavior while performing work processes. In this study a VR tracking sensor system (HTC Vive tracker) combined with an inverse kinematic model (Final IK) was compared with a marker-based optical motion capture system (Qualisys). Marker-based optical motion capture systems are considered the gold standard for motion analysis. Therefore, Qualisys was used as the ground truth in this study. The research question to be answered was how accurately the HTC Vive System combined with Final IK can measure joint angles used for ergonomic evaluation. Twenty-six subjects were observed simultaneously with both tracking systems while performing 20 defined movements. Sixteen joint angles were analyzed. Joint angle deviations between ±6∘ and ±42∘ were identified. These high deviations must be considered in ergonomic risk assessments when using a VR system. The results show that commercial low-budget tracking systems have the potential to map joint angles. Nevertheless, substantial weaknesses and inaccuracies in some body regions must be taken into account. Recommendations are provided to improve tracking accuracy and avoid systematic errors.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6115
Author(s):  
Przemysław Skurowski ◽  
Magdalena Pawlyta

Optical motion capture is a mature contemporary technique for the acquisition of motion data; alas, it is non-error-free. Due to technical limitations and occlusions of markers, gaps might occur in such recordings. The article reviews various neural network architectures applied to the gap-filling problem in motion capture sequences within the FBM framework providing a representation of body kinematic structure. The results are compared with interpolation and matrix completion methods. We found out that, for longer sequences, simple linear feedforward neural networks can outperform the other, sophisticated architectures, but these outcomes might be affected by the small amount of data availabe for training. We were also able to identify that the acceleration and monotonicity of input sequence are the parameters that have a notable impact on the obtained results.


2020 ◽  
Vol 26 ◽  
pp. 00061
Author(s):  
Elina Makarova ◽  
Vladislav Dubatovkin ◽  
Nataliya Berezinskaya ◽  
Lyudmila Barkhatova ◽  
Elena Oleynik

The research is focused on studying the possibility of effective use of the dart grip system, the work of the athlete’s hand, to prepare the dartsman for competitions using the MOSAR complex. The experiment uses optical motion capture systems, a set of video cameras, led parameter sensors, and devices that allow to record the movement of body parts and a dart. This method of training and controlling dart throwing can serve as educational and visual material for training future athletes. The use of such motion capture systems in the near future may become one of the main aspects of training, both beginners and professionals, in many sports.


1999 ◽  
Vol 8 (2) ◽  
pp. 187-203 ◽  
Author(s):  
Tom Molet ◽  
Ronan Boulic ◽  
Daniel Thalmann

Motion-capture techniques are rarely based on orientation measurements for two main reasons: (1) optical motion-capture systems are designed for tracking object position rather than their orientation (which can be deduced from several trackers), (2) known animation techniques, like inverse kinematics or geometric algorithms, require position targets constantly, but orientation inputs only occasionally. We propose a complete human motion-capture technique based essentially on orientation measurements. The position measurement is used only for recovering the global position of the performer. This method allows fast tracking of human gestures for interactive applications as well as high rate recording. Several motion-capture optimizations, including the multijoint technique, improve the posture realism. This work is well suited for magnetic-based systems that rely more on orientation registration (in our environment) than position measurements that necessitate difficult system calibration.


Diagnostics ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 426
Author(s):  
I. Concepción Aranda-Valera ◽  
Antonio Cuesta-Vargas ◽  
Juan L. Garrido-Castro ◽  
Philip V. Gardiner ◽  
Clementina López-Medina ◽  
...  

Portable inertial measurement units (IMUs) are beginning to be used in human motion analysis. These devices can be useful for the evaluation of spinal mobility in individuals with axial spondyloarthritis (axSpA). The objectives of this study were to assess (a) concurrent criterion validity in individuals with axSpA by comparing spinal mobility measured by an IMU sensor-based system vs. optical motion capture as the reference standard; (b) discriminant validity comparing mobility with healthy volunteers; (c) construct validity by comparing mobility results with relevant outcome measures. A total of 70 participants with axSpA and 20 healthy controls were included. Individuals with axSpA completed function and activity questionnaires, and their mobility was measured using conventional metrology for axSpA, an optical motion capture system, and an IMU sensor-based system. The UCOASMI, a metrology index based on measures obtained by motion capture, and the IUCOASMI, the same index using IMU measures, were also calculated. Descriptive and inferential analyses were conducted to show the relationships between outcome measures. There was excellent agreement (ICC > 0.90) between both systems and a significant correlation between the IUCOASMI and conventional metrology (r = 0.91), activity (r = 0.40), function (r = 0.62), quality of life (r = 0.55) and structural change (r = 0.76). This study demonstrates the validity of an IMU system to evaluate spinal mobility in axSpA. These systems are more feasible than optical motion capture systems, and they could be useful in clinical practice.