scholarly journals Influence of double layer filter on mean glandular dose (MGD) and image quality in low energy image of contrast enhanced spectral mammography (LE-CESM)

Radiography ◽  
2021 ◽  
Author(s):  
H.S. Niroshani ◽  
T. Nakamura ◽  
N. Michiru ◽  
T. Negishi
2015 ◽  
Vol 25 (10) ◽  
pp. 2813-2820 ◽  
Author(s):  
U. C. Lalji ◽  
C. R. L. P. N. Jeukens ◽  
I. Houben ◽  
P. J. Nelemans ◽  
R. E. van Engen ◽  
...  

2021 ◽  
Vol 10 (15) ◽  
pp. 3309
Author(s):  
Gisella Gennaro ◽  
Melissa L. Hill ◽  
Elisabetta Bezzon ◽  
Francesca Caumo

Contrast-enhanced mammography (CEM) demonstrates a potential role in personalized screening models, in particular for women at increased risk and women with dense breasts. In this study, volumetric breast density (VBD) measured in CEM images was compared with VBD obtained from digital mammography (DM) or tomosynthesis (DBT) images. A total of 150 women who underwent CEM between March 2019 and December 2020, having at least a DM/DBT study performed before/after CEM, were included. Low-energy CEM (LE-CEM) and DM/DBT images were processed with automatic software to obtain the VBD. VBDs from the paired datasets were compared by Wilcoxon tests. A multivariate regression model was applied to analyze the relationship between VBD differences and multiple independent variables certainly or potentially affecting VBD. Median VBD was comparable for LE-CEM and DM/DBT (12.73% vs. 12.39%), not evidencing any statistically significant difference (p = 0.5855). VBD differences between LE-CEM and DM were associated with significant differences of glandular volume, breast thickness, compression force and pressure, contact area, and nipple-to-posterior-edge distance, i.e., variables reflecting differences in breast positioning (coefficient of determination 0.6023; multiple correlation coefficient 0.7761). Volumetric breast density was obtained from low-energy contrast-enhanced spectral mammography and was not significantly different from volumetric breast density measured from standard mammograms.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
P Poskaite ◽  
M Pamminger ◽  
C Kranewitter ◽  
C Kremser ◽  
M Reindl ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The natural history of thoracic aortic aneurysm (TAA) is one of progressive expansion. Asymptomatic patients who do not meet criteria for repair require conservative management including ongoing aneurysm surveillance, mostly carried out by contrast-enhanced computed tomography angiography (CTA). Purpose To prospectively compare image quality and reliability of a prototype non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). Methods Self-navigated 3D whole-heart 1.5 T MRA was performed in 20 patients (aged 67 ± 8.6 years, 75% male) for sizing of TAA; a subgroup of 18 (90%) patients underwent additional contrast-enhanced CTA on the same day. Subjective image quality was scored according to a 4-point Likert scale and ratings between observers were compared by Cohen’s Kappa statistics. Continuous MRA and CTA measurements were analyzed with regression and Bland-Altman analysis. Results Overall subjective image quality as rated by two observers was 1 [interquartile range (IQR) 1-2] for self-navigated MRA and 1.5 [IQR 1-2] for CTA (p = 0.717). For MRA a perfect inter-observer agreement was found for presence of artefacts and subjective image sharpness (κ=1). Subjective signal inhomogeneity correlated highly with objectively quantified inhomogeneity of the blood pool signal (r = 0.78-0.824, all p <0.0001). Maximum diameters of TAA as measured by self-navigated MRA and CTA showed excellent correlation (r = 0.997, p < 0.0001) without significant inter-method bias (bias -0.0278, lower and upper limit of agreement -0.74 and 0.68, p = 0.749). Inter- and intraobserver correlation of aortic aneurysm as measured by MRA was excellent (r = 0.963 and 0.967, respectively) without significant bias (all p ≤ 0.05). Conclusion Self-navigated 3D whole-heart MRA enables reliable contrast- and radiation free aortic dilation surveillance without significant difference to standardized CTA while providing predictable acquisition time and by offering excellent image quality. Abstract Figure.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Martina Correa Londono ◽  
Nino Trussardi ◽  
Verena C. Obmann ◽  
Davide Piccini ◽  
Michael Ith ◽  
...  

Abstract Background The native balanced steady state with free precession (bSSFP) magnetic resonance angiography (MRA) technique has been shown to provide high diagnostic image quality for thoracic aortic disease. This study compares a 3D radial respiratory self-navigated native MRA (native-SN-MRA) based on a bSSFP sequence with conventional Cartesian, 3D, contrast-enhanced MRA (CE-MRA) with navigator-gated respiration control for image quality of the entire thoracic aorta. Methods Thirty-one aortic native-SN-MRA were compared retrospectively (63.9 ± 10.3 years) to 61 CE-MRA (63.1 ± 11.7 years) serving as a reference standard. Image quality was evaluated at the aortic root/ascending aorta, aortic arch and descending aorta. Scan time was recorded. In 10 patients with both MRA sequences, aortic pathologies were evaluated and normal and pathologic aortic diameters were measured. The influence of artifacts on image quality was analyzed. Results Compared to the overall image quality of CE-MRA, the overall image quality of native-SN-MRA was superior for all segments analyzed (aortic root/ascending, p < 0.001; arch, p < 0.001, and descending, p = 0.005). Regarding artifacts, the image quality of native-SN-MRA remained superior at the aortic root/ascending aorta and aortic arch before and after correction for confounders of surgical material (i.e., susceptibility-related artifacts) (p = 0.008 both) suggesting a benefit in terms of motion artifacts. Native-SN-MRA showed a trend towards superior intraindividual image quality, but without statistical significance. Intraindividually, the sensitivity and specificity for the detection of aortic disease were 100% for native-SN-MRA. Aortic diameters did not show a significant difference (p = 0.899). The scan time of the native-SN-MRA was significantly reduced, with a mean of 05:56 ± 01:32 min vs. 08:51 ± 02:57 min in the CE-MRA (p < 0.001). Conclusions Superior image quality of the entire thoracic aorta, also regarding artifacts, can be achieved with native-SN-MRA, especially in motion prone segments, in addition to a shorter acquisition time.


Author(s):  
Cynthia Schmidt ◽  
Andreas M. Hötker ◽  
Urs J. Muehlematter ◽  
Irene A. Burger ◽  
Olivio F. Donati ◽  
...  

Abstract Background Bowel preparation before multiparametric MRI (mpMRI) of the prostate is performed widely, despite contradictory or no evidence for efficacy. Purpose To investigate the value of hyoscine N-butylbromide (HBB), microenema (ME) and ‘dietary restrictions’ (DR) for artifact reduction and image quality (IQ) in mpMRI of the prostate. Study type Retrospective. Population Between 10/2018 and 02/2020 treatment-naïve men (median age, 64.9; range 39.8–87.3) who underwent mpMRI of the prostate were included. The total patient sample comprised of n = 180 patients, who received either HBB, ME, were instructed to adhere to DR, or received a combination of those measures prior to the MR scan. Field strength/sequence T2-weighted imaging (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced MRI (DCE-MRI) scanned on two 3T systems. Assessment A radiologist specialized in urogenital imaging (R1) and a senior radiology resident (R2) visually assessed IQ parameters on transversal T2w, DWI and ADC maps on a 5-point Likert-like scale. Statistical tests Group comparison between IQ parameters was performed on reader level using Kruskal–Wallis and Mann–Whitney U tests. Binary univariate logistic regression analysis was used to assess independent predictors of IQ. Interrater agreement was assessed using Intraclass Correlation Coefficient (ICC). Results ‘DWI geometric distortion’ was significantly more pronounced in the HBB+/ME−/DR− (R1, 3.6 and R2, 4.0) as compared to the HBB−/ME+/DR− (R1, 4.2 and R2, 4.6) and HBB+/ME+/DR− (R1, 4.3 and R2, 4.7) cohort, respectively. Parameters ‘DWI IQ’ and ‘Whole MRI IQ’ were rated similarly by both readers. ME was a significant independent predictor of ‘good IQ’ for the whole MRI for R1 [b = 1.09, OR 2.98 (95% CI 1.29, 6.87)] and R2 [b = 1.01, OR 2.73 (95% CI 1.24, 6.04)], respectively. Data conclusion ME seems to significantly improve image quality of DWI and the whole mpMRI image set of the prostate. HBB and DR did not have any benefit.


2021 ◽  
Vol 143 ◽  
pp. 109914
Author(s):  
Luigi Camera ◽  
Giuseppina Dell'Aversano-Orabona ◽  
Michele Gambardella ◽  
Federica Riccitiello ◽  
Roberta Galatola ◽  
...  

Author(s):  
Christina Konstantopoulos ◽  
Tejas S Mehta ◽  
Alexander Brook ◽  
Vandana Dialani ◽  
Rashmi Mehta ◽  
...  

Abstract Objective Low-energy (LE) images of contrast-enhanced mammography (CEM) have been shown to be noninferior to digital mammography. However, our experience is that LE images are superior to 2D mammography. Our purpose was to compare cancer appearance on LE to 2D images. Methods In this IRB-approved retrospective study, seven breast radiologists evaluated 40 biopsy-proven cancer cases on craniocaudal (CC) and mediolateral oblique (MLO) LE images and recent 2D images for cancer visibility, confidence in margins, and conspicuity of findings using a Likert scale. Objective measurements were performed using contrast-to-noise ratio (CNR) estimated from regions of interest placed on tumor and background parenchyma. Reader agreement was evaluated using Fleiss kappa. Per-reader comparisons were performed using Wilcoxon test and overall comparisons used three-way analysis of variance. Results Low-energy images showed improved performance for visibility (CC LE 4.0 vs 2D 3.5, P &lt; 0.001 and MLO LE 3.7 vs 2D 3.5, P = 0.01), confidence in margins (CC LE 3.2 vs 2D 2.8, P &lt; 0.001 and MLO LE 3.1 vs 2D 2.9, P &lt; 0.008), and conspicuity compared to tissue density compared to 2D mammography (CC LE 3.6 vs 2D 3.2, P &lt; 0.001 and MLO LE 3.5 vs 2D 3.2, P &lt; 0.001). The average CNR was significantly higher for LE than for digital mammography (CC 2.1 vs 3.2, P &lt; 0.001 and MLO 2.1 vs 3.4, P &lt; 0.001). Conclusion Our results suggest that cancers may be better visualized on the LE CEM images compared with the 2D digital mammogram.


Diagnostics ◽  
2018 ◽  
Vol 8 (4) ◽  
pp. 84
Author(s):  
Aman Saini ◽  
Alex Wallace ◽  
Hassan Albadawi ◽  
Sailendra Naidu ◽  
Sadeer Alzubaidi ◽  
...  

Lower extremity peripheral arterial disease (PAD) is a chronic, debilitating disease with a significant global burden. A number of diagnostic imaging techniques exist, including computed tomography angiography (CTA) and contrast-enhanced magnetic resonance angiography (CEMRA), to aid in PAD diagnosis and subsequent treatment planning. Due to concerns of renal toxicity or nephrogenic systemic fibrosis (NSF) for iodinated and gadolinium-based contrasts, respectively, a number of non-enhanced MRA (NEMRA) protocols are being increasingly used in PAD diagnosis. These techniques, including time of flight and phase contrast MRA, have previously demonstrated poor image quality, long acquisition times, and/or susceptibility to artifacts when compared to existing contrast-enhanced techniques. In recent years, Quiescent-Interval Single-Shot (QISS) MRA has been developed to overcome these limitations in NEMRA methods, with promising results. Here, we review the various screening and diagnostic tests currently used for PAD. The various NEMRA protocols are discussed, followed by a comprehensive review of the literature on QISS MRA to date. A particular emphasis is placed on QISS MRA feasibility studies and studies comparing the diagnostic accuracy and image quality of QISS MRA versus other diagnostic imaging techniques in PAD.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Carolin Reimann ◽  
Julia Brangsch ◽  
Jan Ole Kaufmann ◽  
Lisa C. Adams ◽  
David C. Onthank ◽  
...  

Objectives. The aim of this study was to test the potential of a new elastin-specific molecular agent for the performance of contrast-enhanced first-pass and 3D magnetic resonance angiography (MRA), compared to a clinically used extravascular contrast agent (gadobutrol) and based on clinical MR sequences. Materials and Methods. Eight C57BL/6J mice (BL6, male, aged 10 weeks) underwent a contrast-enhanced first-pass and 3D MR angiography (MRA) of the aorta and its main branches. All examinations were on a clinical 3 Tesla MR system (Siemens Healthcare, Erlangen, Germany). The clinical dose of 0.1 mmol/kg was administered in both probes. First, a time-resolved MRA (TWIST) was acquired during the first-pass to assess the arrival and washout of the contrast agent bolus. Subsequently, a high-resolution 3D MRA sequence (3D T1 FLASH) was acquired. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all sequences. Results. The elastin-specific MR probe and the extravascular imaging agent (gadobutrol) enable high-quality MR angiograms in all animals. During the first-pass, the probes demonstrated a comparable peak enhancement (300.6 ± 32.9 vs. 288.5 ± 33.1, p>0.05). Following the bolus phase, both agents showed a comparable intravascular enhancement (SNR: 106.7 ± 11 vs. 102.3 ± 5.3; CNR 64.5 ± 7.4 vs. 61.1 ± 7.2, p>0.05). Both agents resulted in a high image quality with no statistical difference (p>0.05). Conclusion. The novel elastin-specific molecular probe enables the performance of first-pass and late 3D MR angiography with an intravascular contrast enhancement and image quality comparable to a clinically used extravascular contrast agent.