Quantitative phase analysis of cubic boron nitride based composites by X-ray absorption near edge structure

2007 ◽  
Vol 62 (5) ◽  
pp. 461-469 ◽  
Author(s):  
Edyta Piskorska ◽  
Krystyna Lawniczak-Jablonska ◽  
Roman Minikayev ◽  
Anna Wolska ◽  
Wojciech Paszkowicz ◽  
...  
MRS Advances ◽  
2017 ◽  
Vol 2 (29) ◽  
pp. 1545-1550 ◽  
Author(s):  
Nicholas L. McDougall ◽  
Jim G. Partridge ◽  
Desmond W. M. Lau ◽  
Philipp Reineck ◽  
Brant C. Gibson ◽  
...  

ABSTRACTCubic boron nitride (cBN) is a synthetic wide band gap material that has attracted attention due to its high thermal conductivity, optical transparency and optical emission. In this work, defects in cBN have been investigated using experimental and theoretical X-ray absorption near edge structure (XANES). Vacancy and O substitutional defects were considered, with O substituted at the N site (ON) to be the most energetically favorable. All defects produce unique signatures in either the B or N K-edges and can thus be identified using XANES. The calculations coupled with electron-irradiation / annealing experiments strongly suggest that ON is the dominant defect in irradiated cBN and remains after annealing. This defect is a likely source of optical emission in cBN.


2014 ◽  
Vol 47 (3) ◽  
pp. 835-846 ◽  
Author(s):  
Alessandro F. Gualtieri ◽  
Vincenzo Riva ◽  
Andrea Bresciani ◽  
Stefano Maretti ◽  
Marco Tamburini ◽  
...  

For the first time, this work inspects the accuracy of quantitative phase analysis of both crystalline and amorphous components of stoneware tiles and bricks. A number of variables were considered: the nature of the internal standard, experimental conditions and counting statistics. The so-calledG-factor method has also been applied. The results of the X-ray powder diffraction analysis have been compared with the results obtained with optical microscopy and image analysis. Only the mixtures spiked with corundum and silicon yielded accurate weight estimates of the amorphous fraction, whereas the use of highly X-ray absorbing internal standards (such as fluorite, rutile and zincite) resulted in gross underestimations. In fact, microabsorption effects are found to drastically reduce the accuracy of the results when standards with linear X-ray absorption coefficients higher than 100 cm−1are employed. It was found that very low counting statistics reduced the calculated amorphous fractions in both bricks and stoneware tiles owing to partial masking of the major peak of the internal standard, namely corundum. The application of theG-factor method to the systems investigated was also evaluated. The results are poorer than those obtained using the internal standard.


2004 ◽  
Vol 362 (1-2) ◽  
pp. 171-177 ◽  
Author(s):  
E Piskorska ◽  
K Lawniczak-Jablonska ◽  
I.N Demchenko ◽  
E Benko ◽  
E Welter

1966 ◽  
Vol 38 (12) ◽  
pp. 1741-1745 ◽  
Author(s):  
R. F. Karlak ◽  
D. S. Burnett

1957 ◽  
Vol 1 ◽  
pp. 39-58
Author(s):  
Ralph H. Hiltz ◽  
Stanley L. Lopata

AbstractIn view of present difficulties encountered in met alio graphic methods of phase analysis of titanium and its alloys, the possibility of utilizing integrated X-ray intensities for phase analysis was investigated. Power Formula variables were calculated for titanium, and relative areas of three alpha and one beta peak were determined. Recorded X-ray intensities were obtained from a large number of titanium specimens. The recorded intensities were analyzed and the results compared with those from metallographic analysis. The errors in the method arising from the nature of titanium, texture and peak overlapping, were studied and where possible, compensated for by adjusting the method of measurement and calculation.


Sign in / Sign up

Export Citation Format

Share Document