Colorimetric determination of DNA concentration and mismatches using hybridization-mediated growth of gold nanoparticle probes

2014 ◽  
Vol 192 ◽  
pp. 77-82 ◽  
Author(s):  
Wei-Feng Fang ◽  
Wen-Jone Chen ◽  
Jing-Tang Yang
RSC Advances ◽  
2016 ◽  
Vol 6 (107) ◽  
pp. 105119-105124 ◽  
Author(s):  
Chi Zhang ◽  
Li-Qiang Lu ◽  
Pan Deng ◽  
Xi-Ke Tian ◽  
Ming-Yang Liu ◽  
...  

3,4-Diaminobenzenethiol can react with AuNPs via a strong covalent Au–S bond. The exposed amino functional groups on the benzene ring from neighboring AuNPs could bind to copper ions, resulting in AuNP aggregation.


2015 ◽  
Vol 182 (9-10) ◽  
pp. 1677-1683 ◽  
Author(s):  
Yuanfu Zhang ◽  
Rui Li ◽  
Qingwang Xue ◽  
Haibo Li ◽  
Jifeng Liu

1959 ◽  
Vol 36 (2) ◽  
pp. 193-201 ◽  
Author(s):  
Julius A. Goldbarg ◽  
Esteban P. Pineda ◽  
Benjamin M. Banks ◽  
Alexander M. Rutenburg

2013 ◽  
Vol 12 (7) ◽  
pp. 460-465
Author(s):  
Sameer Amereih ◽  
Zaher Barghouthi ◽  
Lamees Majjiad

A sensitive colorimetric determination of fluoride in drinking water has been developed using a polymeric zirconium complex of 5-(2-Carboxyphenylazo)-8-Hydroxyquinoline as fluoride reagents. The method allowed a reliable determination of fluoride in range of (0.0-1.5) mg L-1. The molar absorptivity of the complex formation is 7695 ± 27 L mol-1 cm-1 at 460 nm. The sensitivity, detection limit, quantitation limit, and percentage recovery for 1.0 mg L-1 fluoride for the proposed method were found to be 0.353 ± 0.013 μg mL-1, 0.1 mg L-1, 0.3 mg L-1, and 101.7 ± 4.1, respectively.


Author(s):  
Abbas Shebeeb Al-kadumi ◽  
Sahar Rihan Fadhel ◽  
Mohammed Abdullah Ahmed ◽  
Luma Amer Musa

We proposed two simple, rapid, and convenient spectrophotometric methods are described for the determination of Amoxicillin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in first method) and colorimetric determination of the green colored solution for manganite ion at 610 nm formed after reaction of Amoxicillin with potassium permanganate as oxidant agent (in the second method) in basic medium. The working conditions of the methods were investigated and optimized. Beer's law plot showed a good correlation in the concentration range of 5-45 μg/ml. The detection limits and relative standared deviations were (2.573, 2.814 μg/ml) (2.137, 2.498) for the flame emission photometric method and (1.844, 2.016 μg/ml) (1.645,1.932) for colorimetric methods for capsules and suspensions respectively. The methods were successfully applied to the determination of Amoxicillin in capsules and suspensions, and the obtained results were in good agreement with the label claim. No interference was observed from the commonly encountered additives and expectancies.


Sign in / Sign up

Export Citation Format

Share Document