Modified solar chimney configuration with a heat exchanger: Experiment and CFD simulation

2021 ◽  
Vol 22 ◽  
pp. 100850
Author(s):  
D.M. Aliaga ◽  
R. Feick ◽  
W.K. Brooks ◽  
M. Mery ◽  
R. Gers ◽  
...  
2018 ◽  
Vol 62 (4) ◽  
pp. 255-260
Author(s):  
Shiv Lal ◽  
Subhash Chand Kaushik

In this communication, integrated approach of solar chimney and borehole heat exchanger has been studied by using computational fluid dynamics software. It is observed that, the room temperature can be maintained at 25-30 °C, at 4.9 ACH with this integrated approach in both peak summer and winter conditions. The cooling and heating effects are evaluated as 4.73-5.55 kW at 40 °C in summer and 8.27-10.56 kW at 5 °C in winter. The SC-BHE integrated system approach produced 21-37 % higher heating effect than the BHE alone system. In cooling mode SC fitted after the room in fluid circuit and it produces the induce effect for air suction from BHE along the air blower. So, integrated approach is a feasible solution for building space conditioning.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Chin Yung Shin ◽  
Normah Mohd-Ghazali

In this research, the trapezoidal shaped chevron plate heat exchanger (PHE) is simulated using computational fluid dynamics (CFD) software to determine its heat transfer capacity and friction factor. The PHE is modelled with chevron angles from 30° to 60°, and also the performances are compared with the plain PHE. The validation is done by comparing simulation result with published references using 30° trapezoidal chevron PHE. The Nusselt number and friction factor obtained from simulation model is plotted against different chevron angles. The Nusselt number and friction factor is also compared with available references, which some of the references used sinusoidal chevron PHE. The general pattern of Nusselt number and friction factor with increasing chevron angle agrees with the references. The heat transfer capacity found in current study is higher than the references used, and at the same time, the friction factor also increased. Besides this, it is also found that the counter flow configuration has better heat transfer capacity performance than the parallel flow configuration.


Energy generation to the present growing population is a crucial challenge for the power sector. Heat exchangers (HE) plays an important role in the industrial development. In this present work an attempt is made to develop a Shell-and- Tube Heat Exchanger (STHE) with segmental baffles using commercial CATIA V5 and Autodesk CFD Simulation Softwares. TEMA standards are considered for design of STHE with baffle-cut of 25%. 3-different sets of fluids are allowed to pass through the shell and tube sides i.e. Methanol - Sea Water (M-S), Distilled Water – Raw Water (D-R) and Kerosene- Crude Oil (K-C). The boundary conditions imposed for analysis are fluid inlet temperatures and velocities. ϵ-NTU is employed for the validation of simulation results and found good agreement between them. Results are plotted for temperature, pressure and velocity contours. The performance of the STHE is shown best for the K-C fluid set among other fluid sets.


2018 ◽  
Vol 136 ◽  
pp. 144-153 ◽  
Author(s):  
Jian Zhou ◽  
Ming Ding ◽  
Haozhi Bian ◽  
Yinxing Zhang ◽  
Zhongning Sun

2020 ◽  
Vol 174 ◽  
pp. 115290 ◽  
Author(s):  
Kai Li ◽  
Enlu Wang ◽  
Qi Wang ◽  
Naveed Husnain ◽  
Deli Li

2015 ◽  
Vol 55 (4) ◽  
pp. 267 ◽  
Author(s):  
Jan Skočilas ◽  
Ievgen Palaziuk

<p>This paper deals with a computational fluid dynamics (CFD) simulation of the heat transfer process during turbulent hot water flow between two chevron plates in a plate heat exchanger. A three-dimensional model with the simplified geometry of two cross-corrugated channels provided by chevron plates, taking into account the inlet and outlet ports, has been designed for the numerical study. The numerical model was based on the shear-stress transport (SST) <em>k-!</em> model. The basic characteristics of the heat exchanger, as values of heat transfer coefficient and pressure drop, have been investigated. A comparative analysis of analytical calculation results, based on experimental data obtained from literature, and of the results obtained by numerical simulation, has been carried out. The coefficients and the exponents in the design equations for the considered plates have been arranged by using simulation results. The influence on the main flow parameters of the corrugation inclination angle relative to the flow direction has been taken into account. An analysis of the temperature distribution across the plates has been carried out, and it has shown the presence of zones with higher heat losses and low fluid flow intensity.</p>