Top-down model of calcium carbonate scale formation in turbulent pipe flows

Author(s):  
L. Moriconi ◽  
T. Nascimento ◽  
B.G. B. de Souza ◽  
J.B.R. Loureiro
2019 ◽  
Vol 145 (9) ◽  
pp. 04019052 ◽  
Author(s):  
Bishow N. Shaha ◽  
Daniel E. Meeroff ◽  
Kevin Kohn ◽  
Timothy G. Townsend ◽  
John D. Schert ◽  
...  

Geothermics ◽  
1989 ◽  
Vol 18 (1-2) ◽  
pp. 83-88 ◽  
Author(s):  
Evangelos Dalas ◽  
Petros G. Koutsoukos

Water ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 3428
Author(s):  
Chanbasha Basheer ◽  
Amjad A. Shaikh ◽  
Eid M. Al-Mutairi ◽  
Mokhtar Noor El Deen ◽  
Khurram Karim Qureshi

In this study, ultrasonication-assisted calcium carbonate scale inhibition was investigated compared with a commercial antiscalant ATMP (amino tris(methyl phosphonic acid)). The effects of varying ultrasound amplitude, pH, and inhibition duration were evaluated. The inhibition of calcium carbonate scale formation was measured based on the concentration of calcium in the solution after subjecting to different conditions. Scale deposits were also characterized using scanning electron microscopy and X-ray diffraction spectroscopy. Inhibition of scale formation was supported at a pH of 7 for an ultrasound amplitude of 150 W. A 94% calcium carbonate inhibition was recorded when the experiment was carried out with ultrasonication. The use of 5 mg/L ATMP achieved a 90% calcium carbonate inhibition of ATMP. The result of the characterization revealed that the morphology of the crystals was unaffected by ultrasonic irradiation. Sample treatment was performed with two different membranes to evaluate the calcium carbonate deposition, and data reveals that, at identical conditions, ultrasonication provides less deposition when compared to the control experiments.


Author(s):  
A. Saifelnasr ◽  
M. Bakheit ◽  
K. Kamal ◽  
A. Lila

In this study the predictions and probabilities of calcium carbonate scale formation and corrosion occurrence inside Gumry Field Process Facilities (GFPF) and produced water injection process units (PWTP) was carried out. This was done calculating the Langelier Saturation Index (LSI), Ryznar Stability Index (RSI), Puckorius Scaling Index (PSI). The samples results for LSI index and PSI index were compared and found that all samples under threaten of calcium carbonate scale. The samples results for RSI index and found that all samples under formation of heavy calcium carbonate scale. Special excel computer program was designed to calculate the (LSI, RSI, PSI). The scale was cleaned and removed by 10% diluted hydrochloric acid and commercial scale inhibitor.


2019 ◽  
Vol 169 ◽  
pp. 29-37
Author(s):  
Suharso Suharso ◽  
Eka Setiososari ◽  
Agung Abadi Kiswandono ◽  
Buhani Buhani ◽  
Heri Satria

Sign in / Sign up

Export Citation Format

Share Document