Theoretical analysis and experimental confirmation of the uniformity principle of temperature difference field in heat exchanger

2002 ◽  
Vol 45 (10) ◽  
pp. 2119-2127 ◽  
Author(s):  
Zeng-Yuan Guo ◽  
Sen-Quan Zhou ◽  
Zhi-Xin Li ◽  
Lin-Gen Chen
2012 ◽  
Vol 170-173 ◽  
pp. 2521-2524
Author(s):  
Wen Li ◽  
Jun Hua Wan ◽  
Jing Liu ◽  
Zu Yi Zheng ◽  
Wen Ming Xu

The model of solution heat exchangers of mixed absorption refrigeration cycle was developed. The effects of strong solution temperature difference between inlet and outlet of solution heat exchanger on the coefficient of performance (COP) and cooling water flow rate of mixed absorption refrigeration cycle were analyzed, at the same time, the effects of temperature difference on the unit heat exchange area of counter-flow and cross-flow solution heat exchangers were analyzed. The theoretical analysis results showed that there was an optimal value for the strong solution temperature difference, for the mixed absorption system, the optimal temperature difference was about 12°C, the corresponding COP was 11.2% higher and the cooling water flow rate was 7.8% less than that of system without heat exchanger.


2021 ◽  
Vol 190 ◽  
pp. 116798
Author(s):  
Hechang Cai ◽  
Yuling Zhai ◽  
Yao Chen ◽  
Fanhan Liu ◽  
Hua Wang ◽  
...  

2017 ◽  
Vol 139 (2) ◽  
Author(s):  
Jiuyi Liu ◽  
Caifu Qian ◽  
Huifang Li

Thermal stress is an important factor influencing the strength of a heat exchanger tubesheet. Some studies have indicated that, even in floating-head or U-tube heat exchangers, the thermal stress at the tubesheet is significant in magnitude. For exploring the value, distribution, and the influence factors of the thermal stress at the tubesheet of these kind heat exchangers, a tubesheet and triangle arranged tubes with the tube diameter of 25 mm were numerically analyzed. Specifically, the thermal stress at the tubesheet center is concentrated and analyzed with changing different parameters of the tubesheet, such as the temperature difference between tube-side and shell-side fluids, tubesheet diameter, thickness, and the tube-hole area ratio. It is found that the thermal stress of the tubesheet of floating-head or U-tube heat exchanger was comparable in magnitude with that produced by pressures, and the distribution of the thermal stress depends on the tube-hole area and the temperature inside the tubes. The thermal stress at the center of the tubesheet surface is high when tube-hole area ratio is very low. And with increasing the tube-hole area ratio, the stress first decreases rapidly and then increases linearly. A formula was numerically fitted for calculating the thermal stress at the tubesheet surface center which may be useful for the strength design of the tubesheet of floating-head or U-tube heat exchangers when considering the thermal stress. Numerical tests show that the fitted formula can meet the accuracy requirements for engineering applications.


Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 594
Author(s):  
Tao Zhou ◽  
Bingchao Chen ◽  
Huanling Liu

In recent years, in order to obtain a radiator with strong heat exchange capacity, researchers have proposed a lot of heat exchangers to improve heat exchange capacity significantly. However, the cooling abilities of heat exchangers designed by traditional design methods is limited even if the geometric parameters are optimized at the same time. However, using topology optimization to design heat exchangers can overcome this design limitation. Furthermore, researchers have used topology optimization theory to designed one-to-one and many-to-many inlet and outlet heat exchangers because it can effectively increase the heat dissipation rate. In particular, it can further decrease the hot-spot temperature for many-to-many inlet and outlet heat exchangers. Therefore, this article proposes novel heat exchangers with three inlets and one outlet designed by topology optimization to decrease the fluid temperature at the outlet. Subsequently, the effect of the channel depth on the heat exchanger design is also studied. The results show that the type of exchanger varies with the channel depth, and there exists a critical depth value for obtaining the minimum substrate temperature difference. Then, the flow and heat transfer performance of the heat exchangers are numerically investigated. The numerical results show that the heat exchanger derived by topology optimization with the minimum temperature difference as the goal (Model-2) is the best design for flow and heat transfer performance compared to other heat sink designs, including the heat exchanger derived by topology optimization having the average temperature as the goal (Model-1) and conventional straight channels (Model-3). The temperature difference of Model-1 can be reduced by 37.5%, and that of Model-2 can be decreased by 62.5% compared to Model-3. Compared with Model-3, the thermal resistance of Model-1 can be reduced by 21.86%, while that of Model-2 can be decreased by 47.99%. At room temperature, we carried out the forced convention experimental test for Model-2 to measure its physical parameters (temperature, pressure drop) to verify the numerical results. The error of the average wall temperature between experimental results and simulation results is within 2.6 K, while that of the fluid temperature between the experimental and simulation results is within 1.4 K, and the maximum deviation of the measured Nu and simulated Nu was less than 5%. This indicated that the numerical results agreed well with the experimental results.


2019 ◽  
Vol 8 (4) ◽  
pp. 2704-2712

The refrigerants are usually provided in the conventional refrigeration system despite the fact that, they produce CFCs and HCFCs, which are hazardous to the environment. However, these disadvantages can be overcome using air or inert gas in the thermoacoustic refrigeration system. The present research involves the effect of spacing of parallel plate stack on the performance of thermoacoustic refrigerator (TAR) in terms of temperature difference (∆T). The entire resonator system as well as other structural parts of the refrigerator are fabricated by using PVC to reduce conduction heat loss. Three parallel plate stacks have been used to study the performance of TAR considering different porosity ratios by varying the gap between the parallel plates (0.28 mm, 0.33 mm and 0.38 mm). The parallel plate stacks are fabricated by using aluminium and mylar sheet material and the working fluid used for the experimental study is helium. The experiments have been carried out with different drive ratios ranging from 0.6% to 1.6% with operating frequencies of 200 – 600 Hz. Also the mean operating pressure used for the experiment is 2 to 10 bar and cooling load of 2 to 10W are considered. The ∆T between the hot heat exchanger and cold heat exchanger is recorded using RTDs and Bruel and Kjaer data acquisition system. Experimental results shows that the lowest temperature measured at cold heat exchanger is -2.1 oC by maintaining the hot heat exchanger temperature at about 32 oC. The maximum temperature difference of 32.90 oC is achieved.