97/03193 Implications of indoor climate control for comfort, energy and environment

1997 ◽  
Vol 38 (4) ◽  
pp. 260
2019 ◽  
Vol 9 (22) ◽  
pp. 4945 ◽  
Author(s):  
Daiqi Li ◽  
Bin Tang ◽  
Xi Lu ◽  
Quanxiang Li ◽  
Wu Chen ◽  
...  

In this study, a single firing was used to convert stabilized polyacrylonitrile (PAN) fibers and ceramic forming materials (kaolin, feldspar, and quartz) into carbon fiber/ceramic composites. For the first time, PAN carbonization and ceramic sintering were achieved simultaneously in one thermal cycle and the microscopic morphologies and physical features of the obtained carbon fiber/ceramic composites were characterized in detail. The obtained carbon fiber/ceramic composite showed comparable flexural strength as commercial ceramic tiles. Meanwhile, the composite showed exceptional electro-thermal performance based on the electro-thermal performance of the carbonized PAN fibers, which could reach 108 ℃ after 15 s, 204 ℃ after 90 s, and 292 ℃ after 450 s at 5 V (2.6 A), thereby making the ceramic composite a good candidate as an indoor climate control heater, defogger device, kettle, and other heating element.


Buildings ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 152
Author(s):  
Karin Kompatscher ◽  
Rick P. Kramer ◽  
Bart Ankersmit ◽  
Henk L. Schellen

The majority of cultural heritage is stored in archives, libraries and museum storage spaces. To reduce degradation risks, many archives adopt the use of archival boxes, among other means, to provide the necessary climate control and comply with strict legislation requirements regarding temperature and relative air humidity. A strict ambient indoor climate is assumed to provide adequate environmental conditions near objects. Guidelines and legislation provide requirements for ambient indoor climate parameters, but often do not consider other factors that influence the near-object environment, such as the use of archival boxes, airflow distribution and archival rack placement. This study aimed to provide more insight into the relation between the ambient indoor conditions in repositories and the hygrothermal conditions surrounding the collection. Comprehensive measurements were performed in a case study archive to collect ambient, local and near-object conditions. Both measurements and computational fluid dynamics (CFD) modeling were used to research temperature/relative humidity gradients and airflow distribution with a changing rack orientation, climate control strategy and supply as well as exhaust set-up in a repository. The following conclusions are presented: (i) supplying air from one air handling unit to multiple repositories on different floors leads to small temperature differences between them. Differences in ambient and local climates are noticed; (ii) archival boxes mute and delay variations in ambient conditions as expected—however, thermal radiation from the building envelope may have a large influence on the climate conditions in a box; (iii) adopting night reduction for energy conservation results in an increased influence of the external climate, with adequate insulation, this effect should be mitigated; and (iv) the specific locations of the supply air and extraction of air resulted in a vertical gradient of temperature and insufficient mixing of air, and adequate ventilation strategies should enhance sufficient air mixing in combination with the insulation of external walls, and gradient forming should be reduced.


Energies ◽  
2017 ◽  
Vol 10 (9) ◽  
pp. 1368 ◽  
Author(s):  
Georgios Kontes ◽  
Georgios Giannakis ◽  
Philip Horn ◽  
Simone Steiger ◽  
Dimitrios Rovas

2019 ◽  
Vol 23 (2) ◽  
pp. 41-52 ◽  
Author(s):  
Marie Claesson ◽  
Tor Broström

Abstract The Swedish National Research programme for Energy Efficiency in historic buildings was initiated in 2006 by the Swedish Energy Agency. This article gives an overview of the programme: objectives, projects and the general results of the programme. The research programme aims to develop knowledge, methods and technical solutions that contribute to energy efficiency in historically valuable buildings without destroying or damaging the historical value of the buildings, including decoration, furnishings, interiors or equipment. The programme is not limited to listed and monumental buildings but covers a wider range of historic buildings that account for a large part of the energy use in the building sector. For one and two-family houses, around 25 % of the energy use is associated with buildings built before 1945. The same number for multifamily houses is around 15 %. The programme is currently in its third consecutive four-year-stage. Previous four-year-stages were completed in 2010 and 2014. Over time, the scope of the programme and the projects have developed from mainly dealing with indoor climate control in monumental buildings towards addressing more general issues in the much larger stock of non-listed buildings. Technical research, based on quantitative analysis, dominate throughout all three stages, however most projects have had interdisciplinary components. The results from the programme have been presented in 31 journal papers, 67 conference papers, five books and five PhD theses. The projects have also contributed to CEN standards and resulted in a number of Bachelors and Master’s theses. An equally important long-term effect of the programme is that the number of Swedish researchers in the field have increased from practically none in 2007 to 18 senior researchers and twelve PhD students from ten universities in 2014. The research programme on Energy Efficiency in historic buildings is unique in an international context. Hopefully it can serve as an example for other countries on how to address an important interdisciplinary research challenge.


2017 ◽  
Vol 134 ◽  
pp. 518-527 ◽  
Author(s):  
Francesca Stazi ◽  
Benedetta Gregorini ◽  
Andrea Gianangeli ◽  
Gabriele Bernardini ◽  
Enrico Quagliarini

Author(s):  
Busari Sherif A. ◽  
Dunmoye Abibat F. ◽  
Akingbade Kayode F.

Data Acquisition Systems (DAS) are used for a variety of applications such as environmental monitoring, indoor climate control, health management and medical diagnostics, traffic surveillance and emergency response, disaster management among others. This paper presents the design of a DAS for monitoring environmental temperature, pressure and relative humidity. The system employs Arduino Uno microcontroller for signal processing and Zigbee transceivers operating on the 2.4 GHz license-free Industrial, Scientific and Medical (ISM) band as communication modules at both the transmitter and receiver ends. While the transmitter board houses the sensors, a GPS module and an LCD, the receiver system is interfaced with a PC which runs a developed MATLAB GUI for data display and analysis and it incorporates an SD card for data storage. The battery-powered system is a low cost, low-power consumption system which serves as a mini-weather station with real-time data logging, wireless communication and tracking capabilities.


2019 ◽  
Vol 111 ◽  
pp. 01010
Author(s):  
David Hunt ◽  
Naoise Mac Suibhne ◽  
Laurentiu Dimache ◽  
David McHugh ◽  
John Lohan

The European Union’s 2020 and 2030 sustainable energy policies seek significant reductions in both energy consumption and carbon emissions. These policies demand a greater use of energy efficient technologies and a transition away from fossil fuels. This paper studies one such technology, an indoor climate control system with a reverse-flow enthalpy recovery ventilator, capable of recovering both sensible and latent heat. The thermal performance characteristics are established using an experimental facility and calculation methods defined by European Standard EN 13141-7:2010. This involves measurement of temperature, humidity, pressure and volumetric air flow rates over a range of operating conditions. Total thermal energy recovery rates ranged from 0.63 kW to 2.2 kW, with energy recovery efficiency of 72.8 % to 88.6 %. The recovery efficiency ratio, which reflects the capacity of the indoor climate control system to recover thermal energy relative to its power consumption ranged between 6.87 to 19.97. Due to the unique reverse-flow defrost function, the system demonstrates operation down to -7 °C without frost formation. These results highlight the potential that this system can make towards the EU goals of reducing energy consumption, operating costs and carbon emissions associated with indoor climate control.