Author(s):  
A. Tanaka ◽  
M. Yamaguchi ◽  
T. Hirano

The plasma polymerization replica method and its apparatus have been devised by Tanaka (1-3). We have published several reports on its application: surface replicas of biological and inorganic specimens, replicas of freeze-fractured tissues and metal-extraction replicas with immunocytochemical markers.The apparatus for plasma polymerization consists of a high voltage power supply, a vacuum chamber containing a hydrocarbon gas (naphthalene, methane, ethylene), and electrodes of an anode disk and a cathode of the specimen base. The surface replication by plasma polymerization in negative glow phase on the cathode was carried out by gassing at 0.05-0.1 Torr and glow discharging at 1.5-3 kV D.C. Ionized hydrocarbon molecules diffused into complex surface configurations and deposited as a three-dimensionally polymerized film of 1050 nm in thickness.The resulting film on the complex surface had uniform thickness and showed no granular texture. Since the film was chemically inert, resistant to heat and mecanically strong, it could be treated with almost any organic or inorganic solvents.


1990 ◽  
Vol 55 (8) ◽  
pp. 1959-1967 ◽  
Author(s):  
Petr Vaňura ◽  
Pavel Selucký

The extraction of polyethylene glycol of average molecular mass 400 (PEG 400) with dicarbolide solution in nitrobenzene and of longer-chain polyethylene glycol, of average molecular mass 1 500 (PEG 1 500), with chlorinated dicarbolide solution in nitrobenzene was studied. During the extraction of PEG 400, the polyethylene glycol solvates the Horg+ ion in the organic phase giving rise to the HLorg+ species (L is polyethylene glycol). The obtained value of the extraction constant Kex(HLorg+) = 933 is consistent with published data of metal extraction. Extraction of PEG 1 500 was treated applying the simplified assumption that the thermodynamic behaviour of PEG 1 500 is the same as that of n molecules of polyethylene glycol with relative molecular mass 1 500/n, each solvating one cation. For this model, the value of n = 3.2 ± 1.1 and the values of the extraction constants of the HL1/n,org+ and HL2/n,org+ species were obtained by using the adapted program LETAGROP. This value of n is consistent with published extraction data in the presence of polyethylene glycol with a relative molecular mass from 200 to 1 000.


1961 ◽  
Vol 236 (3) ◽  
pp. 964-967 ◽  
Author(s):  
S.H. Richardson ◽  
Sydney C. Rittenberg
Keyword(s):  

Author(s):  
Chi M. Phan ◽  
Son A. Hoang ◽  
Son H. Vu ◽  
Hoang M. Nguyen ◽  
Cuong V. Nguyen ◽  
...  

Abstract Background Cashew nut shell is a by-product of cashew (Anacardium occidentale) production, which is abundant in many developing countries. Cashew nut shell liquor (CNSL) contains a functional chemical, cardanol, which can be converted into a hydroxyoxime. The hydroxyoximes are expensive reagents for metal extraction. Methods CNSL-based oxime was synthesized and used to extract Ni, Co, and Mn from aqueous solutions. The extraction potential was compared against a commercial extractant (LIX 860N). Results All metals were successfully extracted with pH0.5 between 4 and 6. The loaded organic phase was subsequently stripped with an acidic solution. The extraction efficiency and pH0.5 of the CNSL-based extractant were similar to a commercial phenol-oxime extractant. The metals were stripped from the loaded organic phase with a recovery rate of 95% at a pH of 1. Conclusions Cashew-based cardanol can be used to economically produce an oxime in a simple process. The naturally-based oxime has the economic potential to sustainably recover valuable metals from spent lithium-ion batteries. Graphic abstract


Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 77
Author(s):  
Davide Spanu ◽  
Gilberto Binda ◽  
Marcello Marelli ◽  
Laura Rampazzi ◽  
Sandro Recchia ◽  
...  

A laser ablation–inductively coupled plasma–mass spectrometry (LA–ICP–MS) based method is proposed for the quantitative determination of the spatial distribution of metal nanoparticles (NPs) supported on planar substrates. The surface is sampled using tailored ablation patterns and the data are used to define three-dimensional functions describing the spatial distribution of NPs. The volume integrals of such interpolated surfaces are calibrated to obtain the mass distribution of Ag NPs by correlation with the total mass of metal as determined by metal extraction and ICP–MS analysis. Once this mass calibration is carried out on a sacrificial sample, quantifications can be performed over multiple samples by a simple micro-destructive LA–ICP–MS analysis without requiring the extraction/dissolution of metal NPs. The proposed approach is here tested using a model sample consisting of a low-density polyethylene (LDPE) disk decorated with silver NPs, achieving high spatial resolution over cm2-sized samples and very high sensitivity. The developed method is accordingly a useful analytical tool for applications requiring both the total mass and the spatial distribution of metal NPs to be determined without damaging the sample surface (e.g., composite functional materials and NPs, decorated catalysts or electrodic materials).


1961 ◽  
Vol 236 (3) ◽  
pp. 959-963
Author(s):  
S.H. Richardson ◽  
Sydney C. Rittenberg
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document