Posture, spontaneous movements, and behavioural state organisation in infants affected by brain malformations

1997 ◽  
Vol 50 (1) ◽  
pp. 87-113 ◽  
Author(s):  
Fabrizio Ferrari ◽  
Heinz F.R. Prechtl ◽  
Giovanni Cioni ◽  
M.Federica Roversi ◽  
Christa Einspieler ◽  
...  
2019 ◽  
Vol 18 (02) ◽  
pp. 123-125
Author(s):  
Vinay Agarwal ◽  
Namit Singhal

AbstractChorea is defined as a state of excessive spontaneous movements, irregularly timed, nonrepetitive, randomly distributed, and abrupt in character. Thalamic and subthalamic lesions are commonly known to cause hemichorea. Here, we describe a patient with hydrocephalus due to aqueductal stenosis that caused hemichorea in the immediate postoperative period due to subthalamic infarct of uncus herniation. Considering that hydrocephalus symmetrically affects the central nervous system, the asymmetric presentation of chorea in the immediate postoperative period after wakening up from anesthesia could be confusing if a possibility of uncus herniation is not considered.


Animals ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 91
Author(s):  
Jaime Manning ◽  
Deborah Power ◽  
Amy Cosby

The five freedoms and, more recently, the five domains of animal welfare provide internationally recognised frameworks to evaluate animal welfare practices which recognise both the physical and mental wellbeing needs of animals, providing a balanced view of their ability to cope in their environment. Whilst there are many techniques to measure animal welfare, the challenge lies with how best to align these with future changes in definitions and expectations, advances in science, legislative requirements, and technology improvements. Furthermore, enforcement of current animal welfare legislation in relation to livestock in Australia and the reliance on self-audits for accreditation schemes, challenges our ability to objectively measure animal welfare. On-animal sensors have enormous potential to address animal welfare concerns and assist with legislative compliance, through continuous measurement and monitoring of an animal’s behavioural state and location being reflective of their wellbeing. As reliable animal welfare measures evolve and the cost of on-animal sensors reduce, technology adoption will increase as the benefits across the supply chain are realised. Future adoption of on-animal sensors by producers will primarily depend on a value proposition for their business being clear; algorithm development to ensure measures are valid and reliable; increases in producer knowledge, willingness, and trust in data governance; and improvements in data transmission and connectivity.


2020 ◽  
Vol 11 (1) ◽  
pp. 21
Author(s):  
Claudia Brogna ◽  
Valentina Milano ◽  
Barbara Brogna ◽  
Lara Cristiano ◽  
Giuseppe Rovere ◽  
...  

The partial trisomy 13q encompasses an extensive variability of phenotypic and radiological findings including leukoencephalopathy and brain malformations such as holoprosencephaly, callosal dysgenesis, hippocampal hypoplasia, olfactory hypoplasia, and vermian hypoplasia. We report for the first time a case of a 23-year-old patient affected by de novo partial 13q22.1q34 trisomy (41.7 Mb, 72,365,975-114,077,122x3) presenting with hemiparesis related to both ischemic and haemorrhagic cerebral lesions compatible with cerebral vasculitis due to a possible combination of genetic and immunological interaction.


1993 ◽  
Vol 69 (3) ◽  
pp. 953-964 ◽  
Author(s):  
P. W. Glimcher ◽  
D. L. Sparks

1. The first experiment of this study determined the effects of low-frequency stimulation of the monkey superior colliculus on spontaneous saccades in the dark. Stimulation trains, subthreshold for eliciting short-latency fixed-vector saccades, were highly effective at biasing the metrics (direction and amplitude) of spontaneous movements. During low-frequency stimulation, the distribution of saccade metrics was biased toward the direction and amplitude of movements induced by suprathreshold stimulation of the same collicular location. 2. Low-frequency stimulation biased the distribution of saccade metrics but did not initiate movements. The distribution of intervals between stimulation onset and the onset of the next saccade did not differ significantly from the distribution of intervals between an arbitrary point in time and the onset of the next saccade under unstimulated conditions. 3. Results of our second experiment indicate that low-frequency stimulation also influenced the metrics of visually guided saccades. The magnitude of the stimulation-induced bias increased as stimulation current or frequency was increased. 4. The time course of these effects was analyzed by terminating stimulation immediately before, during, or after visually guided saccades. Stimulation trains terminated at the onset of a movement were as effective as stimulation trains that continued throughout the movement. No effects were observed if stimulation ended 40–60 ms before the movement began. 5. These results show that low-frequency collicular stimulation can influence the direction and amplitude of spontaneous or visually guided saccades without initiating a movement. These data are compatible with the hypothesis that the collicular activity responsible for specifying the horizontal and vertical amplitude of a saccade differs from the type of collicular activity that initiates a saccade.


2014 ◽  
Vol 75 (5) ◽  
pp. 782-787 ◽  
Author(s):  
Ingrid E. Scheffer ◽  
Sarah E. Heron ◽  
Brigid M. Regan ◽  
Simone Mandelstam ◽  
Douglas E. Crompton ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document