5559089 Low-dosage automatic dishwashing detergent with monopersulfate and enzymes

1997 ◽  
Vol 15 (2) ◽  
pp. 514
2012 ◽  
Vol 16 (3) ◽  
pp. 427-434 ◽  
Author(s):  
Izuddin Abdul Rahman ◽  
Raja Noor Zaliha Raja Abdul Rahman ◽  
Abu Bakar Salleh ◽  
Mahiran Basri

2003 ◽  
Vol 66 (2) ◽  
pp. 188-193 ◽  
Author(s):  
JERZY LUKASIK ◽  
MICHAEL L. BRADLEY ◽  
TROY M. SCOTT ◽  
MABEL DEA ◽  
ANDREW KOO ◽  
...  

The efficacy levels of different physical and chemical washing treatments in the reduction of viral and bacterial pathogens from inoculated strawberries were evaluated. Escherichia coli O157:H7, Salmonella Montevideo, poliovirus 1, and the bacteriophages PRD1, φX174, and MS2 were used as model and surrogate organisms. Chemicals readily available to producers and/or consumers were evaluated as antimicrobial additives for the production of washes. The gentle agitation of contaminated strawberries in water for 2 min led to reductions in microbial populations ranging from 41 to 79% and from 62 to 90% at water temperatures of 22 and 43°C, respectively. Significant reductions (>98%) in numbers of bacteria and viruses were obtained with sodium hypochlorite (50 to 300 ppm of free chlorine), Oxine or Carnebon (200 ppm of product generating “stabilized chlorine dioxide”), Tsunami (100 ppm of peroxyacetic acid), and Alcide (100 or 200 ppm of acidified sodium chlorite) washes. Overall, 200 ppm of acidified sodium chlorite produced the greatest reductions of microorganisms. Hydrogen peroxide (0.5%) was slightly less effective than free chlorine in a strawberry wash and caused slight fruit discoloration. Cetylpyridinium chloride (0.1%) was effective in the reduction of bacterial species, while trisodium phosphate (1%) was effective against viruses. The consumer-oriented produce wash Fit was very effective (>99%) in reducing the numbers of bacteria but not in reducing the numbers of viruses. Another wash, Healthy Harvest, was significantly less effective than Fit in reducing bacterial pathogens but more effective for viruses. The performance of automatic dishwashing detergent was similar to that of Healthy Harvest and significantly better than that of liquid dishwashing detergent. Solutions containing table salt (2% NaCl) or vinegar (10%) reduced the numbers of bacteria by about 90%, whereas only the vinegar wash reduced the numbers of viruses significantly (ca. 95%).


Molecules ◽  
2017 ◽  
Vol 22 (9) ◽  
pp. 1577 ◽  
Author(s):  
Ashwini Naganthran ◽  
Malihe Masomian ◽  
Raja Noor Rahman ◽  
Mohd Ali ◽  
Hisham Nooh

Pathology ◽  
1993 ◽  
Vol 25 (1) ◽  
pp. 24-26 ◽  
Author(s):  
Pek-Yoon Chong ◽  
Thiow-Kong Ti

2021 ◽  
Vol 105 ◽  
pp. 307-311 ◽  
Author(s):  
Bastian Steuwer ◽  
Euzebiusz Jamrozik ◽  
Nir Eyal
Keyword(s):  

1988 ◽  
Vol 3 (2) ◽  
pp. 125-130
Author(s):  
D.M. Dieterle ◽  
M. Ackenheil ◽  
H.P. Kapfhammer ◽  
F. Müller-Spahn

RésuméZotepine was studied in 15 schizophrenic patients over a period of 28 days with regard to its antipsychotic efficacy, effect on negative schizophrenic symptoms, tolerability and adverse effects. Nine patients received Zotepine in a high dosage of 230 mg/die±52 mg, 6 patients in a low dosage of 168 mg/die ± 18 mg. Two patients receiving the high dosage dropped out after 21 days because of worsening of symptomatology and suicide attempts. Zotepine had rapid antipsychotic effects with sedative properties during the initial days of treatment. Minimal adverse effects and extra-pyramidal motor disturbances as well as dose-dependent positive effects on negative schizophrenie symptoms were found.


2021 ◽  
Vol 5 (1) ◽  
pp. 9
Author(s):  
Piotr Pawliszak ◽  
Bronwyn H. Bradshaw-Hajek ◽  
Christopher Greet ◽  
William Skinner ◽  
David A. Beattie ◽  
...  

Currently there are no available methods for in-line measurement of gas-liquid interfacial tension during the flotation process. Microfluidic devices have the potential to be deployed in such settings to allow for a rapid in-line determination of the interfacial tension, and hence provide information on frother concentration. This paper presents the development of a simple method for interfacial tension determination based on a microfluidic device with a flow-focusing geometry. The bubble generation frequency in such a microfluidic device is correlated with the concentration of two flotation frothers (characterized by very different adsorption kinetic behavior). The results are compared with the equilibrium interfacial tension values determined using classical profile analysis tensiometry.


Sign in / Sign up

Export Citation Format

Share Document