Toxicological analysis of aluminum in drinking waters and dialysis solutions

1998 ◽  
Vol 6 ◽  
pp. S45
Author(s):  
Trapti Sharma ◽  
R. P. Nagar ◽  
R. C. Gaur ◽  
Pooja Gupta ◽  
Charanjit Kaur

In Rajasthan state the ground waters of some areas like Ramganj-mandi, Morak, Barmer, Jaisalmer, Chittor and Udaipur etc. are susceptible from drinking point of view.To test the quality of groundwater in Chittor district 14, ground water samples were collected from various places and analyzed for pH, E.C., Fluoride and Nitrate parameters by standard methods (A.P.H. A., Washington, USA, 1995). The study revealed that none of the ground waters was found suitable completely from drinking point of view. Some are having electrical conductivity > 1.4 dS/m, some are having pH >8.5, some area having fluoride >1.5 ppm and some are having nitrate>45 ppm. These are the limits of various parameters permitted by various International authorities like Bureau of Indian Standard, Indian Council of Medical Research,world health Organization etc. for drinking waters. So, it is recommended to the residents of above areas to use water for drinking purpose only after reverse osmosis or adopting suitable method of removing excess of Fluoride and Nitrate for drinking water to avoid unwanted pathogenic diseases harmful for human health.


1982 ◽  
Vol 14 (4-5) ◽  
pp. 281-290
Author(s):  
Ph Vilaginès ◽  
B Sarrette ◽  
C Danglot ◽  
R Vilaginès

The aim of this work is to describe a new and inexpensive glass powder apparatus allowing virus concentration from 500 1 sample of water (10). Its efficiency was determined by analysis of drinking and surface waters preinoculated by Poliovirus. The detection of viruses from river water is compared when 500 1 (new apparatus) or 10 1 (preceeding apparatus) (7) are processed. The proposed new 500 1 apparatus allowed the recuperation of viruses in 100 % of the analysed samples the 10 1 one allowing their recuperation in only 50 % samples. This method was applied to the virus determination in the surface and drinking waters of the Paris area.


1982 ◽  
Vol 14 (4-5) ◽  
pp. 59-71 ◽  
Author(s):  
L H Keith ◽  
R C Hall ◽  
R C Hanisch ◽  
R G Landolt ◽  
J E Henderson

Two new methods have been developed to analyze for organic pollutants in water. The first, two-dimensional gas chromatography, using post detector peak recycling (PDPR), involves the use of a computer-controlled gas Chromatograph to selectively trap compounds of interest and rechromatograph them on a second column, recycling them through the same detector again. The second employs a new detector system, a thermally modulated electron capture detector (TMECD). Both methods were used to demonstrate their utility by applying them to the analysis of a new class of potentially ubiquitous anthropoaqueous pollutants in drinking waters- -haloacetonitriles. These newly identified compounds are produced from certain amino acids and other nitrogen-containing compounds reacting with chlorine during the disinfection stage of treatment.


2019 ◽  
Vol 26 (1) ◽  
pp. 177-196 ◽  
Author(s):  
Mateusz Kacper Woźniak ◽  
Marek Wiergowski ◽  
Jacek Namieśnik ◽  
Marek Biziuk

Background:Ethyl alcohol is the most popular legal drug, but its excessive consumption causes social problems. Despite many public campaigns against alcohol use, car accidents, instances of aggressive behaviour, sexual assaults and deterioration in labor productivity caused by inebriated people is still commonplace. Fast and easy diagnosis of alcohol consumption is required in order to introduce proper and effective therapy, and is crucial in forensic toxicology analysis. The easiest method to prove alcohol intake is determination of ethanol in body fluids or in breath. However, since ethanol is rapidly metabolized in the human organism, only recent consumption can be detected using this method. Because of that, the determination of alcohol biomarkers was introduced for monitoring alcohol consumption over a wider range of time.Objective:The objective of this study was to review published studies focusing on the sample preparation methods and chromatographic or biochemical techniques for the determination of alcohol biomarkers in whole blood, plasma, serum and urine.Methods:An electronic literature search was performed to discuss possibilities and limitations of application of alcohol biomarkers in toxicological analysis.Results:Authors described the markers of alcohol consumption such as: ethanol, its nonoxidative metabolites (ethyl glucuronide, ethyl sulfate, phosphatidylethanol, ethyl phosphate, fatty acid ethyl esters) and oxidative metabolites (acetaldehyde and acetaldehyde adducts). We also discussed issues concerning the detection window of these biomarkers, and possibilities and limitations of their use in routine analytical toxicology for monitoring alcohol consumption or sobriety during alcohol therapy.


2019 ◽  
Vol 19 (5) ◽  
pp. 667-676
Author(s):  
José R. Santin ◽  
Gislaine F. da Silva ◽  
Maria V.D. Pastor ◽  
Milena F. Broering ◽  
Roberta Nunes ◽  
...  

Background: It was recently demonstrated that the phthalimide N-(4-methyl-phenyl)-4- methylphthalimide (MPMPH-1) has important effects against acute and chronic pain in mice, with a mechanism of action correlated to adenylyl cyclase inhibition. Furthermore, it was also demonstrated that phthalimide derivatives presented antiproliferative and anti-tumor effects. Considering the literature data, the present study evaluated the effects of MPMPH-1 on breast cancer bone metastasis and correlated painful symptom, and provided additional toxicological information about the compound and its possible metabolites. Methods: In silico toxicological analysis was supported by in vitro and in vivo experiments to demonstrate the anti-tumor and anti-hypersensitivity effects of the compound. Results: The data obtained with the in silico toxicological analysis demonstrated that MPMPH-1 has mutagenic potential, with a low to moderate level of confidence. The mutagenicity potential was in vivo confirmed by micronucleus assay. MPMPH-1 treatments in the breast cancer bone metastasis model were able to prevent the osteoclastic resorption of bone matrix. Regarding cartilage, degradation was considerably reduced within the zoledronic acid group, while in MPMPH-1, chondrocyte multiplication was observed in random areas, suggesting bone regeneration. Additionally, the repeated treatment of mice with MPMPH-1 (10 mg/kg, i.p.), once a day for up to 36 days, significantly reduces the hypersensitivity in animals with breast cancer bone metastasis. Conclusion: Together, the data herein obtained show that MPMPH-1 is relatively safe, and significantly control the cancer growth, allied to the reduction in bone reabsorption and stimulation of bone and cartilage regeneration. MPMPH-1 effects may be linked, at least in part, to the ability of the compound to interfere with adenylylcyclase pathway activation.


1990 ◽  
Vol 10 (1) ◽  
pp. 89-92 ◽  
Author(s):  
Liliane Larpent ◽  
Christian Verger

The fate of the peritoneal membrane on continuous ambulatory peritoneal dialysis (CAPD) is usually evaluated through the modification of its permeability to various solutes as glucose, creatinine, and urea. Therefore, the accuracy of the methods used for measurements of creatinine is of great importance. A particular problem does exist for creatinine determination as it may be influenced by the presence of glucose. We studied a new enzymatic colorimetric method for creatinine determination in peritoneal dialysis solutions which contain high dextrose concentrations. Creatinine was measured in plasma, urine, and dialysate from 18 patients on CAPD and in pure dextrose solutions, with an enzymatic test (Boehringer Mannheim) and with Jaffe's reaction on two different analyzers: Astra (Beckman) and Eris (Merck). Creatinine results were similar with both assays (Jaffe's reaction and enzymatic test) when measured in blood and urine. However the Jaffe's reaction gave higher creatinine results than the enzymatic test (p < 0.001), when assays were performed in peritoneal dialysis solutions and in pure glucose solutions. In addition, it appeared that other components of dialysis solutions, mainly calcium chloride, influenced unpredictably the results of creatinine with the Jaffe's reaction. We conclude that specific enzymatic test is a more accurate and reliable method to evaluate creatinine kinetics through the peritoneal membrane when determined in CAPD solutions.


2021 ◽  
pp. 089686082098212
Author(s):  
Peter Nourse ◽  
Brett Cullis ◽  
Fredrick Finkelstein ◽  
Alp Numanoglu ◽  
Bradley Warady ◽  
...  

Peritoneal dialysis (PD) for acute kidney injury (AKI) in children has a long track record and shows similar outcomes when compared to extracorporeal therapies. It is still used extensively in low resource settings as well as in some high resource regions especially in Europe. In these regions, there is particular interest in the use of PD for AKI in post cardiac surgery neonates and low birthweight neonates. Here, we present the update of the International Society for Peritoneal Dialysis guidelines for PD in AKI in paediatrics. These guidelines extensively review the available literature and present updated recommendations regarding peritoneal access, dialysis solutions and prescription of dialysis. Summary of recommendations 1.1 Peritoneal dialysis is a suitable renal replacement therapy modality for treatment of acute kidney injury in children. (1C) 2. Access and fluid delivery for acute PD in children. 2.1 We recommend a Tenckhoff catheter inserted by a surgeon in the operating theatre as the optimal choice for PD access. (1B) (optimal) 2.2 Insertion of a PD catheter with an insertion kit and using Seldinger technique is an acceptable alternative. (1C) (optimal) 2.3 Interventional radiological placement of PD catheters combining ultrasound and fluoroscopy is an acceptable alternative. (1D) (optimal) 2.4 Rigid catheters placed using a stylet should only be used when soft Seldinger catheters are not available, with the duration of use limited to <3 days to minimize the risk of complications. (1C) (minimum standard) 2.5 Improvised PD catheters should only be used when no standard PD access is available. (practice point) (minimum standard) 2.6 We recommend the use of prophylactic antibiotics prior to PD catheter insertion. (1B) (optimal) 2.7 A closed delivery system with a Y connection should be used. (1A) (optimal) A system utilizing buretrols to measure fill and drainage volumes should be used when performing manual PD in small children. (practice point) (optimal) 2.8 In resource limited settings, an open system with spiking of bags may be used; however, this should be designed to limit the number of potential sites for contamination and ensure precise measurement of fill and drainage volumes. (practice point) (minimum standard) 2.9 Automated peritoneal dialysis is suitable for the management of paediatric AKI, except in neonates for whom fill volumes are too small for currently available machines. (1D) 3. Peritoneal dialysis solutions for acute PD in children 3.1 The composition of the acute peritoneal dialysis solution should include dextrose in a concentration designed to achieve the target ultrafiltration. (practice point) 3.2  Once potassium levels in the serum fall below 4 mmol/l, potassium should be added to dialysate using sterile technique. (practice point) (optimal) If no facilities exist to measure the serum potassium, consideration should be given for the empiric addition of potassium to the dialysis solution after 12 h of continuous PD to achieve a dialysate concentration of 3–4 mmol/l. (practice point) (minimum standard) 3.3  Serum concentrations of electrolytes should be measured 12 hourly for the first 24 h and daily once stable. (practice point) (optimal) In resource poor settings, sodium and potassium should be measured daily, if practical. (practice point) (minimum standard) 3.4  In the setting of hepatic dysfunction, hemodynamic instability and persistent/worsening metabolic acidosis, it is preferable to use bicarbonate containing solutions. (1D) (optimal) Where these solutions are not available, the use of lactate containing solutions is an alternative. (2D) (minimum standard) 3.5  Commercially prepared dialysis solutions should be used. (1C) (optimal) However, where resources do not permit this, locally prepared fluids may be used with careful observation of sterile preparation procedures and patient outcomes (e.g. rate of peritonitis). (1C) (minimum standard) 4. Prescription of acute PD in paediatric patients 4.1 The initial fill volume should be limited to 10–20 ml/kg to minimize the risk of dialysate leakage; a gradual increase in the volume to approximately 30–40 ml/kg (800–1100 ml/m2) may occur as tolerated by the patient. (practice point) 4.2 The initial exchange duration, including inflow, dwell and drain times, should generally be every 60–90 min; gradual prolongation of the dwell time can occur as fluid and solute removal targets are achieved. In neonates and small infants, the cycle duration may need to be reduced to achieve adequate ultrafiltration. (practice point) 4.3 Close monitoring of total fluid intake and output is mandatory with a goal to achieve and maintain normotension and euvolemia. (1B) 4.4 Acute PD should be continuous throughout the full 24-h period for the initial 1–3 days of therapy. (1C) 4.5  Close monitoring of drug dosages and levels, where available, should be conducted when providing acute PD. (practice point) 5. Continuous flow peritoneal dialysis (CFPD) 5.1   Continuous flow peritoneal dialysis can be considered as a PD treatment option when an increase in solute clearance and ultrafiltration is desired but cannot be achieved with standard acute PD. Therapy with this technique should be considered experimental since experience with the therapy is limited. (practice point) 5.2  Continuous flow peritoneal dialysis can be considered for dialysis therapy in children with AKI when the use of only very small fill volumes is preferred (e.g. children with high ventilator pressures). (practice point)


Sign in / Sign up

Export Citation Format

Share Document