Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant

2013 ◽  
Vol 25 (2) ◽  
pp. 295-301 ◽  
Author(s):  
Xiaohong Zhou ◽  
Yuanyuan Wu ◽  
Hanchang Shi ◽  
Yanqing Song
2014 ◽  
Vol 70 (1) ◽  
pp. 8-14 ◽  
Author(s):  
Riccardo Gori ◽  
Alice Balducci ◽  
Cecilia Caretti ◽  
Claudio Lubello

This paper reports the results of a series of off-gas tests aimed at monitoring the evolution of the oxygen transfer efficiency in an urban wastewater treatment plant (3,500 population equivalent) located in Tuscany (Italy). The tests were conducted over a 2-year period starting with the testing of the aeration system. It was found that in the absence of membrane-panel cleaning operations, the oxygen transfer efficiency under standard conditions in process water (αSOTE) dropped from 18 to 9.5% in 2 years. This gives rise to a 40% increase in the wastewater treatment plant annual energy costs. The on-site chemical cleaning of the diffusers allowed for an almost total recovery of the transfer efficiency (αSOTE equal to 16%). The use of the off-gas method for monitoring the oxygen transfer efficiency over time is therefore essential for enabling correct planning of the cleaning operations of the diffusers and for cutting the energy consumption and operating costs of the aeration system.


2019 ◽  
Vol 8 (4) ◽  
pp. 6761-6768

Several methods of wastewater treatment systems are implemented but among these methods activated sludge process is demonstrating process in Malaysia. Fortunately, numbers of studies have been conducted to treat and remove either nitrogen or combined phosphorus and nitrogen resulted in enhancement removal of nutrients worldwide. This research aims to study the current operation in Mawar wastewater treatment plant and monitor the reduction of several parameters. The research also examines the new standard limits of effluents. From the result obtained, the monitoring of Mawar wastewater treatment plant indicates that influent concentration of majority of the parameters were in small. Despite that, the removal efficiency of several parameters was not high. That was basically because to the need of proper maintenance activities. Besides, the concentration of measured parameters in the aeration tank inlet were small. Comparison of Mawar wastewater to the typical composition of untreated domestic sewage indicated that the wastewater in Mawar wastewater treatment plant is classified as weak wastewater. The enhancement of nitrogen removal resulted in Mawar wastewater treatment plant led to decrease the removal efficiency of several parameters.


2010 ◽  
Vol 2 (5) ◽  
pp. 97-102
Author(s):  
Ala Sokolova ◽  
Mindaugas Rimeika

The paper analyzes the impact of the way of mounting a tube diffuser, the design of an aeration tank and the presence of a fixed carrier on the operational parameters of aeration systems used in small wastewater treatment plants. It was found out that the vertically mounted tube diffuser decreased standard oxygen transfer rate (SOTR) of the aeration system by approximately 20% and standard oxygen transfer efficiency (SOTE) by 25% comparing to the horizontally mounted tube diffuser. It was also defined that the design of the aeration tank might have an impact on the operation parameters of the aeration system: when the centre shell used to protect a diffuser was dismantled from a test tank, SOTR and SOTE increased by approximately 20%. It was also established that the presence of the fixed carrier in the aeration tank did not have an impact on the performance of aeration systems. Finally, research was carried out to compare the operational parameters of two diffusers of different types offered on the market and used in small wastewater treatment plants. It was found out that the performance different type diffusers might vary considerably.


2002 ◽  
Vol 46 (10) ◽  
pp. 195-198 ◽  
Author(s):  
C.X. Ramos ◽  
S.L. Estévez ◽  
E. Giraldo

VOCs emitted by two composting static piles of biosolids coming from the “El Salitre” wastewater treatment plant (Bogotá, Colombia) were analysed during the composting process. Each pile in its sampling time was maintained with a different aeration system. The sampling was made using Solid Phase Microextraction (SPME); separation and identifications were made using Gas Chromatography (GC) coupled to Mass Spectrometry (MS). Aliphatic and aromatic hydrocarbons, chlorinated compounds, ketones, mercaptans, alcohols and amines were identified in concentrations greater than the norms stipulated by the EPA for inhalation in humans beings. The emission behavior varied according to the aeration system used.


2008 ◽  
Vol 3 (1) ◽  
Author(s):  
K. Klinksieg ◽  
T. Dockhorn ◽  
N. Dichtl

Full-scale and lab-scale research experiments were conducted to determine the phosphorous precipitation efficiency of iron hydroxide sludge from drinking water treatment. During full-scale investigations at a wastewater treatment plant, ferric sludge was added to the inflow of the primary settling tank in a first experimental phase and to the inflow of the aeration tank in a second phase. In the outflow of the mechanical stage and in the outflow of the biological stage, a reduction of the PO4-P concentrations could be observed. The concentration of COD, the SVI and the filament abundance were not changed significantly by adding the ferric sludge to the wastewater treatment plant. In lab tests, improved precipitation efficiency of the ferric sludge could be achieved by using anaerobic conditions and acid pulping. The research showed that the wastewater treatment process can benefit from the reuse of ferric sludge from drinking waterworks and that this also presents an inexpensive recycling option for these sludges.


Author(s):  
R. Babko ◽  
V. Pliashechnyk ◽  
T. Kuzmina ◽  
Y. Danko ◽  
J. Szulżyk-Cieplak ◽  
...  

Abstract The work is devoted to the task of simplifying the assessment of the effect of effluents from treatment facilities on the river hydrobiocenosis. The studies were carried out on the mountain river Uzh (Uzhgorod, Ukraine). Our approach to assessing the impact of waste treatment facilities on the river receiver is based on the estimate of the similarity of species composition and quantitative characteristics of populations of organisms from the aerotank and from the river. It is shown that the quantitative development of populations of species of ciliates from the aeration tank is a good indicator for assessing the degradation of organic matter coming with wastewater. The use of qualitative and quantitative characteristics of the protozoa from the wastewater treatment plant as a criterion for assessing the quality of the environment in the area of wastewater discharge showed their representativeness and effectiveness. The use of a limited number of species makes it possible to conduct an express assessment of the effect of effluents on receiving reservoirs for specialists working with activated sludge in the laboratories of treatment facilities.


2011 ◽  
Vol 8 (4) ◽  
pp. 363 ◽  
Author(s):  
Lena Vierke ◽  
Lutz Ahrens ◽  
Mahiba Shoeib ◽  
Eric J. Reiner ◽  
Rui Guo ◽  
...  

Environmental contextPolyfluoroalkyl compounds, widely used chemicals in consumer and industrial products, are global pollutants in the environment. Transport mechanisms and environmental pathways of these compounds, however, are not yet fully understood. We show that a wastewater treatment plant can be an important source for polyfluoroalkyl compounds to the atmosphere where they have the potential to be transported long distances. AbstractAn air sampling campaign was conducted at a wastewater treatment plant (WWTP) to investigate air concentrations and particle–gas partitioning of polyfluoroalkyl compounds (PFCs). Samples were collected at an aeration tank and a secondary clarifier using both active high volume samplers and passive samplers comprising sorbent-impregnated polyurethane foam (SIP) disks. Water to air transport of PFCs was believed to be enhanced at the aeration tank owing to aerosol-mediated transport caused by surface turbulence induced by aeration. Mean air concentrations of target PFCs at the aeration tank were enriched relative to the secondary clarifier by factors of ~19, ~4 and ~3 for ∑fluorotelomer alcohols (FTOHs) (11 000 v. 590 pg m–3), ∑perfluorooctane sulfonamides & perfluorooctane sulfonamidoethanols (FOSAs & FOSEs) (120 v. 30 pg m–3) and ∑perfluoroalkyl carboxylates & perfluoroalkyl sulfonates (PFCAs & PFSAs) (4000 v. 1300 pg m–3) respectively. The particle associated fraction in the atmosphere increased with increasing chain length for PFCAs (from 60 to 100%) and PFSAs were predominantly bound to particles (~98%). Lower fractions on particles were found for FTOHs (~3%), FOSAs (~30%) and FOSEs (~40%). The comparison of the active and passive air sampling showed good agreement.


Sign in / Sign up

Export Citation Format

Share Document