Ordering of the fibrous eutectic microstructure of Al–Al3Ni due to accelerated solidification conditions

2000 ◽  
Vol 48 (8) ◽  
pp. 1939-1948 ◽  
Author(s):  
L Ratke ◽  
J Alkemper
2019 ◽  
Vol 147 ◽  
pp. 303-310 ◽  
Author(s):  
Eder S.N. Lopes ◽  
Mariana R. Dal Bó ◽  
Victor C. Opini ◽  
Mariana G. de Mello ◽  
Carlos T. Rios ◽  
...  

2006 ◽  
Vol 980 ◽  
Author(s):  
Sho Tokui ◽  
Kazuhiro Ishikawa ◽  
Kiyoshi Aoki

AbstractIt has been demonstrated that the as-cast Nb40Ti30Ni30 duplex phase alloy, which consists of the primary (Nb, Ti) solid solution and the fine lamellar type eutectic {TiNi+(Nb, Ti)} phase, shows higher hydrogen permeability ¶ than that of pure Pd without the hydrogen embrittlement at 673K. In this alloy, the eutectic phase contributes to the suppression of the hydrogen embrittlement, while the primary one does mainly to the hydrogen permeation. It is important to note that even if the eutectic microstructure disappears and is replaced by the small spherical (Nb, Ti) phase embedded in the TiNi matrix by rolling and subsequent annealing, its high hydrogen permeability and large resistance to the hydrogen embrittlement are sustained. Furthermore, the present authors have observed that the primary (Nb, Ti) phase is largely elongated along the rolling direction. Consequently, it is expected that rolled and annealed Nb-Ti-Ni alloys show the large anisotropy of the microstructure and the hydrogen permeability. In the present work, the microstructure and hydrogen permeability ¶nof the Nb40Ti30Ni30 alloy after rolling and annealing treatments are examined in order to develop highly hydrogen permeable alloys utilizing the anisotropic microstructure.The primary (Nb, Ti) phase and the very fine eutectic {TiNi+(Nb, Ti)} phase are observed in the as-cast Nb40Ti30Ni30 alloy by scanning electron microscopy (SEM). The X-ray diffractometry (XRD) indicates that this alloy consists of the B2-TiNi intermetallic compounds and the bcc- (Nb, Ti) solid solution. The primary (Nb, Ti) phase is largely elongated along the rolling direction by forging and subsequent rolling at 1173 K. On the other hand, the eutectic microstructure becomes unclear with increasing the rolling reduction. The composite alloys in which the (Nb, Ti) phase is elongated along to the rolling direction are obtained by 69 % rolling reduction. ¶n of this sample is four times higher than that of as-cast one. On the other hand, ¶ for the sample vertical to the rolling direction is reduced to about one third of that of as-cast one. Thus, the hydrogen permeability of the Nb40Ti30Ni30 alloy varies about ten times or more depending on the direction of the primary¡]Nb, Ti¡^ phase. We conclude that it is possible to produce highly hydrogen permeable Nb-Ti-Ni alloys using the anisotropy of the microstructure prepared by hot forging and rolling.


2016 ◽  
Vol 433 ◽  
pp. 63-73 ◽  
Author(s):  
A. Darlapudi ◽  
S.D. McDonald ◽  
S. Terzi ◽  
A. Prasad ◽  
M. Felberbaum ◽  
...  

2014 ◽  
Vol 875-877 ◽  
pp. 1525-1528 ◽  
Author(s):  
Er Min Wang ◽  
Qi Hu Hong ◽  
Zhi Ming Ni ◽  
Jin Han

Self-made tension machine was used to measure the evolution of recovery stress under different processing state for NiTiNb alloy. Then, SEM was used to investigate the microstructure evolution. The results show that the range of the highest recovery stress for forged NiTiNb alloy is between 210-215MPa. Otherwise, the recovery stress level of the samples enduring cold drawing and hot rolling is basically same, which all belong to the rage of 210-220MPa. After forging, the firstly precipitated TiNi phase particles become fine, only 5-8μm. The Nb tablets in eutectic microstructure, which originally contributed between TiNi phase particles, appear spheroidization.


Metals ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1484
Author(s):  
Muhammad Mukarram ◽  
M. Awais Munir ◽  
Mohammad Mujahid ◽  
Khurram Yaqoob

Face centered cubic (FCC) high-entropy alloys (HEA) exhibit excellent ductility while body centered cubic (BCC) HEAs are characterized by high strength. Development of fine two-phase eutectic microstructure (consisting of a tough phase such as fcc and a hard phase such as bcc/intermetallic) can help in obtaining an extraordinary combination of strength and ductility in HEAs. Designing eutectic high entropy alloys is an extremely difficult task for which different empirical and non-empirical methods have been previously tried. In the present study, the possibility of developing a eutectic microstructure by the addition of Mo to CoCrFeNi was evaluated by calculation of the pseudo-binary phase diagram. Experimental results validated the presence of eutectic reaction in the calculated phase diagrams; however, small changes in the calculated phase diagrams were proposed. It has been shown that calculated pseudo-binary phase diagrams can provide a very good starting point for the development of eutectic HEAs and help in exponentially reducing the amount of experimental effort that may be required otherwise. Eutectic mixture consisting of FCC (A2) phase and intermetallic phases (σ and μ) was successfully obtained by the addition of Mo to the CoCrFeNi system. The development of the eutectic microstructure showed a profound effect on the mechanical properties. Hardness of the samples increased from 150 HV for CoCrFeNiMo0.1 to 425.5 HV for CoCrFeNiMo1.0, whereas yield strength increased from around 218 MPa for CoCrFeNiMo0.1 to around 1100 MPa for CoCrFeNiMo1.0.


Sign in / Sign up

Export Citation Format

Share Document