Identification of a Liquid-Saturated Steam Heat Exchanger

1982 ◽  
Vol 15 (4) ◽  
pp. 223-228 ◽  
Author(s):  
S. Bittanti ◽  
A. Cividini ◽  
R. Scattolini
Author(s):  
Stanislav Tkachenko ◽  
Nataliya Stepanova

Known methods for preparing saturated steam for use in a heat engineering system are analyzed. It was established that the flow rate of cooling water was overestimated in them, since part of this water is drained into the drainage system of the power plant and contributes part of the heat of the primary superheated steam there. In the proposed method for removing steam overheating before it is fed to a specific heat exchanger, it is proposed to use condensate from the same heat exchanger, moreover, due to evaporation of a part of the condensate (estimated 10 ... 20%), the metal consumption of the condensate drainage system decreases. The heat and mass transfer processes in the closed loop “heat exchanger – condensate line – desuperheater and separation device –– steam of saturated saturated steam – heat exchanger” are analyzed, the balance equations are compiled, the degree of uncertainty of the heat transfer and hydrodynamic processes in two-phase media is analyzed. A steam preparation system has been developed for a heat-technological consumer, in which by using all the condensate obtained in the steam heat exchanger as a cooler and observing a certain distance between the lower tube sheet of the heat exchanger and the central axis of the desuperheater, the problems of condensate drainage, its efficient use and removal of steam overheating are achieved.


Author(s):  
S. Binanti ◽  
D.W. Clarke ◽  
F. Romeo ◽  
R. Scattolini

1983 ◽  
Vol 16 (1) ◽  
pp. 631-638
Author(s):  
S. Bittanti ◽  
D.W. Clarke ◽  
F. Romeo ◽  
R. Scattolini

Molecules ◽  
2020 ◽  
Vol 25 (8) ◽  
pp. 1999 ◽  
Author(s):  
Qiuyi Wang ◽  
Xinwu Wu ◽  
Chenglong Yuan ◽  
Zhichao Lou ◽  
Yanjun Li

The aim of this study was to investigate the effects of the heat treatment time and initial moisture content of bamboo on the corresponding chemical composition, crystallinity, and mechanical properties after saturated steam heat treatment at 180 °C. The mechanism of saturated steam heat treatment of bamboo was revealed on the micro-level, providing a theoretical basis for the regulation of bamboo properties and the optimization of heat treatment process parameters. XRD patterns of the treated bamboo slices were basically the same. With the increase in the initial moisture content of bamboo, the crystallinity of bamboo increased first and then decreased after treatment. Due to the saturated steam heat treatment, the content of cellulose and lignin in bamboo slices increased while the content of hemicellulose decreased, but the content of cellulose in bamboo with a 40% initial moisture content increased first and then decreased. The shear strength of treated bamboo changed little within 10 min after saturated steam heat treatment, and then decreased rapidly. During the first 20 min with saturated steam heat treatment, the compressive strength, flexural strength, and flexural modulus of elasticity of the treated bamboo increased, and then decreased.


Author(s):  
Qun Zheng ◽  
Minghong Li ◽  
Yufeng Sun

Thermodynamic performance of wet compression and regenerative (WCR) gas turbine are investigated in this paper. The regenerative process can be achieved by a gas/air (and steam) heat exchanger, a regenerator, or by a heat recovery steam generator and then the steam injected into the gas turbine. Several schemes of the above wet compression and regenerative cycles are computed and analyzed. The calculated results indicate that not only a significant specific power can be obtained, but also is the WCR gas turbine an economic competitive option of efficient gas turbines.


Energy ◽  
2018 ◽  
Vol 149 ◽  
pp. 375-385 ◽  
Author(s):  
Dabiao Wang ◽  
Yuezheng Ma ◽  
Ran Tian ◽  
Jie Duan ◽  
Busong Hu ◽  
...  

2021 ◽  
Author(s):  
Tiancheng Yuan ◽  
Zhaoshun Wang ◽  
Xin Han ◽  
ZhuRun Yuan ◽  
XinZhou Wang ◽  
...  

Abstract In this paper, in order to analyze the quasi-static properties of Moso bamboo, a new, environmentally friendly and eco-friendly method was used for bamboo thermal modification under the effect of saturated steam. Under saturated steam heat treatment, the chemical composition in bamboo decreased, and the bamboo cell wall shrunk slightly. The increased crystallinity index of cellulose and decreased intensity of peaks belong to hemicellulose were confirmed by XRD and Fourier transform infrared (FTIR) spectroscopy. In addition, the highest modulus of elastic and hardness of treated bamboo were 22.5GPa and 1.1GPa at 180℃/10 min. These conclusions confirmed the micro-mechanical properties of the bamboo cell wall were enhanced by saturated steam heat treatment. The E'r of differently treated bamboo increased with increasing temperature and time, while the E''r and tan δ negatively as a function of increasing frequency. Furthermore, this thermal modification can be regarded as a useful, environmental-friendly and eco-friendly treatment to outdoor use of bamboo-based materials.


2021 ◽  
Vol 9 (2B) ◽  
Author(s):  
Marcos Filardy Curi

The most common and reliable methodology for determining temperature profiles of Inverted U-tubes Steam Generators is using Computational Fluid Dynamics (CFD) programs. In this work, we developed a modified methodology, using the Wolfram Mathematica software, in order to determine, with good approximation, the temperature profiles of these kind of equipment. The first step was to determine expressions for the physical properties of the water in the operational conditions, like density, thermal conductivity, specific heat and dynamic viscosity. Geometrical parameters like tubes diameter and sub-channel flowing area, as well as the flow parameters like flow mass of primary and secondary fluid, were also considered for determining the numbers of Reynolds, Prandtl, Nusselt and, consequently, the variation of convective coefficients and the global heat transfer coefficient. With subroutines that use the method of the lines we were able to solve the partial differential equations applied to parallel and countercurrent heat exchangers with no phase change. The U-tubes SG were divided in two regions which the first one was calculated considering a parallel heat exchanger and the second one was calculated considering a countercurrent heat exchanger, depending on the flow direction of the primary and secondary circuit. During the phase change, a constant variation of the enthalpy was considered, making the primary fluid temperature decrease following a linear behavior. Using the developed methodology called “Enthalpy Ruler”, the encountered results were considered adequate, since the defined lengths are compatible with the constant variation of the enthalpy from the compressed liquid to saturated steam.


Author(s):  
Jong Chull Jo ◽  
Kyu Sik Do ◽  
Yong Kab Lee

A PWR design incorporates a passive auxiliary feedwater system equipped with one passive condensation heat exchanger (PCHX) which consists of inclined V-shaped tube bundles submerged in a water pool of which the top is open to the atmosphere. During the PCHX operation, saturated steam flows into the PCHX where steam is condensed inside of the tubes by cooling the outer side with the pool water. Then, the condensate flows out passively by gravity. Because the thermal-hydraulic characteristics in the PCHX determine the condensation mass rate and the possibility of thermal stratification-induced fatigue of the pool tank wall, system instability and waterhammer, it is important to understand the phase change flow in the PCHX. In this paper, the complex phase change heat transfer and multi-phase flow in a PCHX tube model were numerically simulated. The single fluid multi-component flow model with the equilibrium phase change model was employed for the condensation phase change flow inside the tube and the two-fluid model with the wall boiling model and the equilibrium phase change model was used for the boiling-induced natural convection outside the tube in the pool. Based on the present numerical simulation, the characteristics of the heat transfer and flow in the PCHX are discussed and illustrated for some typical results.