scholarly journals LO49: Can the HINTS exam rule out stroke in those with vertigo? A systematic review and meta-analysis

CJEM ◽  
2019 ◽  
Vol 21 (S1) ◽  
pp. S25
Author(s):  
R. Ohle ◽  
R. Montpellier ◽  
V. Marchadier ◽  
A. Wharton ◽  
S. McIsaac

Introduction: Acute vestibular syndrome (AVS - vertigo, nystagmus, head motion intolerance, ataxia, and nausea/vomiting) is a subset of patients presenting with vertigo. They are most often due to benign vestibular neuritis but can be a sign of a vertebrobasilar stroke. The HINTS (head impulse test, nystagmus, positive test of skew) exam has been proposed as an extremely accurate bedside test to rule out stroke in those presenting with AVS. Is the HINTS exam compared to MRI sufficiently sensitive to rule out vertebrobasliar stroke in an adult population presenting to the emergency department with AVS. Methods: We searched in Pubmed, Medline, Embase, the Cochrane database, and relevant conference abstracts from 1968 to December 2018 and performed hand searches. No restrictions for language or study type were imposed. Relevant studies were reviewed and data was extracted by two independent reviewers. Gold standard in ruling out stroke was; Negative late acute (72 hrs–10d) cranial MRI with DWI OR Negative early acute (0–72hrs) cranial MRI plus negative follow-up cranial MRI or clinical follow-up for TIA/stroke of ≥3 months. Included studies were prospective or retrospective with patients presenting with acute vestibular syndrome. Studies combined if low clinical and statstitical heterogeonity. Study quality was assessed using the QUADAS tool. Random effects meta analysis using Revman 5 and SAS9.3 was performed. Results: 6 studies with 715 participants were included( QUADAS 12/14 SD 1.2). Average study length 5.3 years ( STD 3.3 years) . Prevalence of vertebrobasilar stroke ranged 9.3-76% (Mean 39.1% SD 17.1). The most common diagnosis were vertebrobasilar stroke (Mean 34.8% SD 17.1%), peripheral cause (Mean 30.9% SD 16%). Intra cerebral haemorrhage (Mean 2.2%, SD 0.5%). Neurologist/neuro ophthalmologist performed the exam in 5/6 studies. 1 study reported a kappa between emergency medicine physician and neurologist of 0.24-0.41. The HINTS exam had a sensitivity of 96% (CI 95% 0.92-0.98, I2-0%), Specificity 91.4% (CI 95% 64.5-98.4% I2 94%). Positive likelihood ratio 11.9 ( CI 95% 2.9-48.8) and a negative likelihood ratio of 0.04 ( CI 95% 0.01– 0.14). Conclusion: The HINTS exam has excellent diagnostic accuracy for ruling out stroke when performed by a neurologist. The lack of ER proven diagnostic accuracy and high prevalence of serious diagnosis in those presenting with acute vestibular syndrome suggests care should be taken in ruling out central cause of dizziness in this population.

2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2021 ◽  
pp. 1-11
Author(s):  
Bing-Jie Xiang ◽  
Min Jiang ◽  
Ming-Jun Sun ◽  
Cong Dai

<b><i>Objective:</i></b> Fecal calprotectin (FC) is a promising marker for assessment of inflammatory bowel disease (IBD) activity. However, the utility of FC for predicting mucosal healing (MH) of IBD patients has yet to be clearly demonstrated. The objective of our study was to perform a meta-analysis evaluating the diagnostic accuracy of FC in predicting MH of IBD patients. <b><i>Methods:</i></b> We systematically searched the databases for studies from inception to April 2020 that evaluated MH in IBD. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. <b><i>Results:</i></b> Sixteen studies comprising 1,682 ulcerative colitis (UC) patients and 4 studies comprising 221 Crohn’s disease (CD) patients were included. The best performance of FC for predicting MH in UC was at cut-off range of 60–75 μg/g with area under the curve (AUC) of 0.88 and pooled sensitivity and specificity of 0.87 and 0.79, respectively. The pooled sensitivity and specificity values of cutoff range 180–250 μg/g for predicting MH in CD were 0.67 and 0.76, respectively. The AUC of 0.79 also revealed improved discrimination for identifying MH in CD with FC concentration. <b><i>Conclusion:</i></b> Our meta-analysis has found that FC is a simple, reliable noninvasive marker for predicting MH in IBD patients. FC cutoff range 60–75 μg/g appears to have the best overall accuracy in UC patients.


2021 ◽  
Vol 11 (6) ◽  
pp. 568
Author(s):  
Óscar Rapado-González ◽  
Cristina Martínez-Reglero ◽  
Ángel Salgado-Barreira ◽  
Laura Muinelo-Romay ◽  
Juan Muinelo-Lorenzo ◽  
...  

DNA hypermethylation is an important epigenetic mechanism for gene expression inactivation in head and neck cancer (HNC). Saliva has emerged as a novel liquid biopsy representing a potential source of biomarkers. We performed a comprehensive meta-analysis to evaluate the overall diagnostic accuracy of salivary DNA methylation for detecting HNC. PubMed EMBASE, Web of Science, LILACS, and the Cochrane Library were searched. Study quality was assessed by the Quality Assessment for Studies of Diagnostic Accuracy-2, and sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (dOR), and their corresponding 95% confidence intervals (CIs) were calculated using a bivariate random-effect meta-analysis model. Meta-regression and subgroup analyses were performed to assess heterogeneity. Eighty-four study units from 18 articles with 8368 subjects were included. The pooled sensitivity and specificity of salivary DNA methylation were 0.39 and 0.87, respectively, while PLR and NLR were 3.68 and 0.63, respectively. The overall area under the curve (AUC) was 0.81 and the dOR was 8.34. The combination of methylated genes showed higher diagnostic accuracy (AUC, 0.92 and dOR, 36.97) than individual gene analysis (AUC, 0.77 and dOR, 6.02). These findings provide evidence regarding the potential clinical application of salivary DNA methylation for HNC diagnosis.


BMJ Open ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. e033084 ◽  
Author(s):  
Jin-Rong Ni ◽  
Pei-Jing Yan ◽  
Shi-Dong Liu ◽  
Yuan Hu ◽  
Ke-Hu Yang ◽  
...  

ObjectiveTo evaluate the diagnostic accuracy of transthoracic echocardiography (TTE) in patients with pulmonary hypertension (PH).DesignSystematic review and meta-analysis.Data sources and eligibility criteriaEmbase, Cochrane Library for clinical trials, PubMed and Web of Science were used to search studies from inception to 19 June, 2019. Studies using both TTE and right heart catheterisation (RHC) to diagnose PH were included.Main resultsA total of 27 studies involving 4386 subjects were considered as eligible for analysis. TTE had a pooled sensitivity of 85%, a pooled specificity of 74%, a pooled positive likelihood ratio of 3.2, a pooled negative likelihood ratio of 0.20, a pooled diagnostic OR of 16 and finally an area under the summary receiver operating characteristic curve of 0.88. The subgroup with the shortest time interval between TTE and RHC had the best diagnostic effect, with sensitivity, specificity and area under the curve (AUC) of 88%, 90% and 0.94, respectively. TTE had lower sensitivity (81%), specificity (61%) and AUC (0.73) in the subgroup of patients with definite lung diseases. Subgroup analysis also showed that different thresholds of TTE resulted in a different diagnostic performance in the diagnosis of PH.ConclusionTTE has a clinical value in diagnosing PH, although it cannot yet replace RHC considered as the gold standard. The accuracy of TTE may be improved by shortening the time interval between TTE and RHC and by developing an appropriate threshold. TTE may not be suitable to assess pulmonary arterial pressure in patients with pulmonary diseases.PROSPERO registration numberPROSPERO CRD42019123289.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Ali Pormohammad ◽  
Mohammad Javad Nasiri ◽  
Timothy D. McHugh ◽  
Seyed Mohammad Riahi ◽  
Nathan C. Bahr

ABSTRACTThe diagnosis of tuberculous meningitis (TBM) is difficult and poses a significant challenge to physicians worldwide. Recently, nucleic acid amplification (NAA) tests have shown promise for the diagnosis of TBM, although their performance has been variable. We undertook a systematic review and meta-analysis to evaluate the diagnostic accuracy of NAA tests with cerebrospinal fluid (CSF) samples against that of culture as the reference standard or a combined reference standard (CRS) for TBM. We searched the Embase, PubMed, Web of Science, and Cochrane Library databases for the relevant records. The QUADAS-2 tool was used to assess the quality of the studies. Diagnostic accuracy measures (i.e., sensitivity and specificity) were pooled with a random-effects model. All statistical analyses were performed with STATA (version 14 IC; Stata Corporation, College Station, TX, USA), Meta-DiSc (version 1.4 for Windows; Cochrane Colloquium, Barcelona, Spain), and RevMan (version 5.3; The Nordic Cochrane Centre, the Cochrane Collaboration, Copenhagen, Denmark) software. Sixty-three studies comprising 1,381 cases of confirmed TBM and 5,712 non-TBM controls were included in the final analysis. These 63 studies were divided into two groups comprising 71 data sets (43 in-house tests and 28 commercial tests) that used culture as the reference standard and 24 data sets (21 in-house tests and 3 commercial tests) that used a CRS. Studies which used a culture reference standard had better pooled summary estimates than studies which used CRS. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the NAA tests against culture were 82% (95% confidence interval [CI], 75 to 87%), 99% (95% CI, 98 to 99%), 58.6 (95% CI, 35.3 to 97.3), and 0.19 (95% CI, 0.14 to 0.25), respectively. The pooled sensitivity, specificity, PLR, and NLR of NAA tests against CRS were 68% (95% CI, 41 to 87%), 98% (95% CI, 95 to 99%), 36.5 (95% CI, 15.6 to 85.3), and 0.32 (95% CI, 0.15 to 0.70), respectively. The analysis has demonstrated that the diagnostic accuracy of NAA tests is currently insufficient for them to replace culture as a lone diagnostic test. NAA tests may be used in combination with culture due to the advantage of time to result and in scenarios where culture tests are not feasible. Further work to improve NAA tests would benefit from the availability of standardized reference standards and improvements to the methodology.


2020 ◽  
pp. 084653712090206 ◽  
Author(s):  
Waleed Abdellatif ◽  
Mahmoud Ahmed Ebada ◽  
Souad Alkanj ◽  
Ahmed Negida ◽  
Nicolas Murray ◽  
...  

Purpose: In this systematic review and meta-analysis, we aimed to investigate the accuracy of dual-energy computed tomography (DECT) in the detection of acute pulmonary embolism (PE). Methods: We searched Medline (via PubMed), EBSCO, Web of Science, Scopus, and the Cochrane Library for relevant published studies. We selected studies assessing the accuracy of DECT in the detection of PE. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 tool. Meta-analysis was performed to calculate mean estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). The summary receiver operating characteristic (sROC) curve was drawn to get the Cochran Q-index and the area under the curve (AUC). Results: Seven studies were included in our systematic review. Of the 182 patients included, 108 patients had PEs. The pooled analysis showed an overall sensitivity and specificity of 88.9% (95% confidence interval [CI]: 81.4%-94.1%) and 94.6% (95% CI: 86.7%-98.5%), respectively. The pooled PLR was 8.186 (95% CI: 3.726-17.986), while the pooled NLR was 0.159 (95% CI: 0.093-0.270). Cochran-Q was 0.8712, and AUC was 0.935 in the sROC curve. Conclusion: Dual-energy computed tomography shows high sensitivity, specificity, and diagnostic accuracy in the detection of acute PE. The high PLR highlights the high clinical importance of DECT as a prevalence-independent, rule-in test. Studies with a larger sample size with standardized reference tests are still needed to increase the statistical power of the study and support these findings.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Daye Cheng ◽  
Ying Sun ◽  
Hu He

The diagnostic value of serum HE4 in patients with lung cancer remains controversial. Thus, we performed a systematic review and meta-analysis to assess the diagnostic accuracy of serum HE4 for lung cancer. We conducted a comprehensive literature search in PubMed, EMBASE, Chinese National Knowledge Infrastructure (CNKI), and WANFANG databases between Jan. 1966 and Nov. 2014. The diagnostic sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and summary receiver operating characteristic curve (SROC) were pooled by Meta-DiSc 1.4 software. A total of seven articles including 715 cases and 549 controls were included for analysis. The summary estimates for serum HE4 in the diagnosis of lung cancer in these studies were pooled SEN 0.72 (95% CI: 0.68–0.75), SPE 0.85 (95% CI: 0.81–0.88), PLR 4.68 (95% CI: 3.23–6.78), NLR 0.31 (95% CI: 0.24–0.39), and DOR 17.14 (95% CI: 9.72–30.20), and the area under the curve (AUC) was 0.8557. This meta-analysis indicated that serum HE4 is a potential tool in the diagnosis of lung cancer. In addition, considering the high heterogeneity and potential publication bias, further studies with rigorous design and large sample size are needed in the future.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2021 ◽  
Vol 22 (Supplement_3) ◽  
Author(s):  
JR Kelderman ◽  
FEJ Jolink ◽  
S Benjamens ◽  
AG Monroy Gonzalez ◽  
RA Pol ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background   A high prevalence of asymptomatic coronary artery disease (CAD) is found in patients with end-stage renal disease evaluated for kidney transplantation.  Purpose  We aimed to assess the diagnostic accuracy of myocardial perfusion imaging (MPI) for CAD in this patients population.  Methods  We performed a systematic literature search and meta-analysis. We retrieved studies investigating the diagnostic accuracy of single-photon emission computed tomography (SPECT) and positron emission tomography (PET) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation. Results  Out of 1379 records, 9 MPI SPECT studies were included in the meta-analysis with a total of 822 patients. There were no studies available using PET with ICA or CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95%-CI 0.52-0.78), pooled specificity 0.72 (95%-CI 0.57-84) and the area under the curve (AUC) 0.74. Positive likelihood ratio (PLR) was 2.31 (95%-CI 1.57-3.39) and negative likelihood ratio (NLR) was 0.41 (95%-CI 0.25-0.68) with an overall diagnostic odds ratio (DOR) of 5.43 (95%-CI 2.87-10.28). Significant heterogeneity existed across included studies. Conclusions  MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings.


Sign in / Sign up

Export Citation Format

Share Document