Diagnosis of toxoplasmosis in pregnancy. Evaluation of latex–protein complexes by immnunoagglutination

Parasitology ◽  
2017 ◽  
Vol 144 (8) ◽  
pp. 1073-1078 ◽  
Author(s):  
LEANDRO E. PERETTI ◽  
VERÓNICA D. G. GONZALEZ ◽  
IVÁN S. MARCIPAR ◽  
LUIS M. GUGLIOTTA

SUMMARYThe aim of this work was to obtain a reagent based on latex particles for ruling out acute toxoplasmosis in pregnant women by immunoagglutination (IA). Latex–protein complexes (LPC) were previously synthesized coupling the recombinant protein ofToxoplasma gondiiP22Ag and the homogenate of the parasite to latex particles with different size, chemical functionality and charge density. LPC were tested in IA assays against a panel of 72 pregnant women serum samples. Results were analysed through receiver operating characteristic curves, determining area under the curve (AUC), sensitivity, specificity positive and negative predictive values (PPV and NPV, respectively). It was observed that the antigenicity of proteins was not affected during sensitization by either physical adsorption or covalent coupling. The best results in the sense of maximizing discrimination of low avidity sera from chronic ones were observed for the IA test based on latex particles with carboxyl functionality and the recombinant P22Ag, obtaining an AUC of 0·94, a sensitivity of 100% and a NPV of 100%. In this way, the proposed test could be useful for the toxoplasmosis diagnosis in pregnant women, with the advantages of being cheap, rapid and easy to be implemented.

Stroke ◽  
2013 ◽  
Vol 44 (suppl_1) ◽  
Author(s):  
Mehrzad Zarghouni ◽  
John S Garrett ◽  
Yahya A Daoud ◽  
Kennith F Layton

Background and Purpose: Despite advances in medical and surgical management, intracerebral hemorrhage (ICH) continues to be associated with significant mortality and morbidity. Several clinical prediction scores (CPS) have been developed to aid in predicting the clinical outcome based upon initial presentation. This study aimed to validate and compare several of the most recently developed CPS to their traditional counterparts. Methods: We retrospectively reviewed 501 consecutive patients with ICH who were admitted from the Emergency Department to the a large healthcare system in Dallas, TX between the dates of 6/1/2009 and 6/1/2011. To validated and compared the FUNC, oICH, and ICH-GS CPS the area under the receiver operating characteristic curves were calculated based upon the ability to predict 90 day mortality and good neurologic outcome (GNO) at the time of discharge, defined as a Glasgow Outcome Score of >4. The sensitivity, specificity, and predictive values of the different ICH scores were computed to determine the test’s ability to identify those without GNO. Results: Of the 501 patients with intracranial hemorrhage, 104 were excluded due to a recognized etiology of their ICH. Complete data was not available in 31 patients. In the resultant 366 patients, the overall mortality at the time of discharge was 114 (31%), 30 (9.5%) of which underwent craniotomy. Of the 252 patients who survived to discharge, 91/252 (36%) survived with GNO. Both the FUNC (AUC: 0.873) and ICH-GS (AUC: 0.888) had similar predictive values and outperformed the oICH (AUC: 0.743) in predicting 90 day mortality (p=<0.001). Similar performance was seen in predicting neurologic outcome at discharge. Table 1. Analysis of ROC Area Under the Curve (AUC) by Outcomes and CPS scores * Significant different from the other two CPS Scores Conclusion: Overall, the FUNC and ICH-GS CPS appear superior to the oICH in our population.


2019 ◽  
Vol 79 (2) ◽  
pp. 169-173 ◽  
Author(s):  
A. L. Cabana ◽  
M. O. Xavier ◽  
J. F. Mendes ◽  
A. J. Teles ◽  
A. M. Martins ◽  
...  

Abstract Even today, an effective diagnostic test for aspergillosis in penguins is unknown, being the gold standard post-mortem examinations. The fungal antigen galactomannan (GM) has been used as a biomarker of disease in humans and is detected by the Platelia Aspergillus EIA (BioRad)®, a commercial kit based on the sandwich ELISA technique. It is standardized for use in neutropenic patients, however studies have demonstrated its usefulness also possible for birds. The aim of our study was to evaluate the effectiveness of Platelia Aspergillus EIA® test (BioRad-US) in the diagnosis of aspergillosis in Magellanic penguins, determining sensitivity, specificity, and positive and negative predictive values for different cut-off points. Were included in the study, blood serum samples (n = 29) Magellanic penguins in captivity that died by aspergillosis. Detection of GM was performed following manufacturer's instructions and the GM index was obtained by dividing the average value of OD of the duplicate of the clinical sample by duplicate OD of the average value of the cut-off sample provided by the kit. Through information database results were obtained for the presence of anti-Aspergillus fumigatus antibodies detected by agar gel immunodiffusion (AGID) for all serum samples. Results were analyzed using chi-square test and Kruskal-Wallis from SPSS 20.0, IBM®. ROC curve was obtained and from this, rates of sensitivity, specificity, positive and negative predictive values were also calculated based on four different cutoff points (0.5, 1.0, 1.5 and 2.0). The serum GM index did not differ between animals of the case and control group (pkw =0.097). In determining the ROC curve for serum GM detection the value of area under the curve was 0.635. From the values determined by the coordinate of the curve, four different cut points (0.5, 1.0, 1.5 and 2.0) were analyzed, resulting in sensitivity rates ranging from 86.2 to 34.5% % and specificity between 87% and 26.1%. By comparing the serum GM index in group case as the presence or absence of antibodies detected by AGID was found p=0.503. The detection of GM the Platelia Aspergillus EIA® test seems is not be useful for the diagnosis of aspergillosis in naturally infected penguins.


2020 ◽  
Vol 163 (6) ◽  
pp. 1156-1165
Author(s):  
Juan Xiao ◽  
Qiang Xiao ◽  
Wei Cong ◽  
Ting Li ◽  
Shouluan Ding ◽  
...  

Objective To develop an easy-to-use nomogram for discrimination of malignant thyroid nodules and to compare diagnostic efficiency with the Kwak and American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS). Study Design Retrospective diagnostic study. Setting The Second Hospital of Shandong University. Subjects and Methods From March 2017 to April 2019, 792 patients with 1940 thyroid nodules were included into the training set; from May 2019 to December 2019, 174 patients with 389 nodules were included into the validation set. Multivariable logistic regression model was used to develop a nomogram for discriminating malignant nodules. To compare the diagnostic performance of the nomogram with the Kwak and ACR TI-RADS, the area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values were calculated. Results The nomogram consisted of 7 factors: composition, orientation, echogenicity, border, margin, extrathyroidal extension, and calcification. In the training set, for all nodules, the area under the curve (AUC) for the nomogram was 0.844, which was higher than the Kwak TI-RADS (0.826, P = .008) and the ACR TI-RADS (0.810, P < .001). For the 822 nodules >1 cm, the AUC of the nomogram was 0.891, which was higher than the Kwak TI-RADS (0.852, P < .001) and the ACR TI-RADS (0.853, P < .001). In the validation set, the AUC of the nomogram was also higher than the Kwak and ACR TI-RADS ( P < .05), each in the whole series and separately for nodules >1 or ≤1 cm. Conclusions When compared with the Kwak and ACR TI-RADS, the nomogram had a better performance in discriminating malignant thyroid nodules.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Lei Xi ◽  
Chunqing Yang

AbstractObjectivesThe main aim of the present study was to assess the diagnostic value of alpha-l-fucosidase (AFU) for hepatocellular carcinoma (HCC).MethodsStudies that explored the diagnostic value of AFU in HCC were searched in EMBASE, SCI, and PUBMED. The sensitivity, specificity, and DOR about the accuracy of serum AFU in the diagnosis of HCC were pooled. The methodological quality of each article was evaluated with QUADAS-2 (quality assessment for studies of diagnostic accuracy 2). Receiver operating characteristic curves (ROC) analysis was performed. Statistical analysis was conducted by using Review Manager 5 and Open Meta-analyst.ResultsEighteen studies were selected in this study. The pooled estimates for AFU vs. α-fetoprotein (AFP) in the diagnosis of HCC in 18 studies were as follows: sensitivity of 0.7352 (0.6827, 0.7818) vs. 0.7501 (0.6725, 0.8144), and specificity of 0.7681 (0.6946, 0.8283) vs. 0.8208 (0.7586, 0.8697), diagnostic odds ratio (DOR) of 7.974(5.302, 11.993) vs. 13.401 (8.359, 21.483), area under the curve (AUC) of 0.7968 vs. 0.8451, respectively.ConclusionsAFU is comparable to AFP for the diagnosis of HCC.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Bo Yao ◽  
Wen-juan Liu ◽  
Di Liu ◽  
Jin-yan Xing ◽  
Li-juan Zhang

Abstract Background Early diagnosis of sepsis is very important. It is necessary to find effective and adequate biomarkers in order to diagnose sepsis. In this study, we compared the value of sialic acid and procalcitonin for diagnosing sepsis. Methods Newly admitted intensive care unit patients were enrolled from January 2019 to June 2019. We retrospectively collected patient data, including presence of sepsis or not, procalcitonin level and sialic acid level. Receiver operating characteristic curves for the ability of sialic acid, procalcitonin and combination of sialic acid and procalcitonin to diagnose sepsis were carried out. Results A total of 644 patients were admitted to our department from January 2019 to June 2019. The incomplete data were found in 147 patients. Finally, 497 patients data were analyzed. The sensitivity, specificity and area under the curve for the diagnosis of sepsis with sialic acid, procalcitonin and combination of sialic acid and procalcitonin were 64.2, 78.3%, 0.763; 67.9, 84.0%, 0.816 and 75.2, 84.6%, 0.854. Moreover, sialic acid had good values for diagnosing septic patients with viral infection, with 87.5% sensitivity, 82.2% specificity, and 0.882 the area under the curve. Conclusions Compared to procalcitonin, sialic acid had a lower diagnostic efficacy for diagnosing sepsis in critically ill patients. However, the combination of sialic acid and procalcitonin had a higher diagnostic efficacy for sepsis. Moreover, sialic acid had good value for diagnosing virus-induced sepsis.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Huseyin Agah Terzi ◽  
Ozlem Aydemir ◽  
Engin Karakece ◽  
Huseyin Hatipoglu ◽  
Mehmet Olmez ◽  
...  

AbstractObjectivesTo test the performance of the newly available rapid test for syphilis, we compared it with Treponema pallidum hemagglutination assay (TPHA). Additionally, we investigated the performance of rapid plasma reagin (RPR) and chemiluminescence microparticle immunoassays (CMIA) at our laboratory using TPHA as a gold standard.MethodsThe serum samples of 595 patients with the pre-diagnosis of syphilis were studied by four serological methods. The sensitivity, specificity, and predictive values of RPR, CMIA, and syphilis rapid test were assessed by utilizing TPHA as a gold standard for the diagnosis of syphilis.ResultsOf the patients, 6.2% (37/595) had positive RPR, 5.5% (33/595) had positive CMIA, 5.5% (33/595) had a positive rapid immunochromatographic method and 5% (30/595) had positive TPHA. When TPHA results were taken as the reference, the sensitivity of the rapid test for syphilis was 100%, the specificity was 99.5%, PPV was 90.9%, and NPV was 100.0%.ConclusionsIt was observed that the rapid test for syphilis used in the study was quite successful, its cost was appropriate, and the test was very fast and easy to apply. At the same time, the agreement between syphilis rapid test and TPHA was found to be excellent.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2017 ◽  
Vol 41 ◽  
pp. 1 ◽  
Author(s):  
Ángel Balmaseda ◽  
Saira Saborío Galo ◽  
Karla González ◽  
Yolanda Téllez ◽  
Nadezna García ◽  
...  

Objective.To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua.Methods.Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014–2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention’s IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used.Results.All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%–95.9%.Conclusion.Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.


2021 ◽  
Vol 104 (3) ◽  
pp. 003685042110368
Author(s):  
Ananya Trongpisutsak ◽  
Vorapong Phupong

The objective was to determine whether a combination of serum micro RNA-210 level and uterine artery Doppler can predict preeclampsia in pregnant women at 16–24 weeks gestation. A prospective observational study conducted in singleton pregnant women at 16–24 weeks of gestation who had prenatal care at the King Chulalongkorn Memorial Hospital, Department of Obstetrics and Gynecology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand between 2017 and 2018. Uterine artery Doppler ultrasound and blood testing for serum micro RNA-210 were performed. Pregnancy outcomes were recorded. Optimal cut-off for uterine artery pulsatility index (PI) and serum micro RNA-210 were obtained to calculate the predictive values for preeclampsia. Data from 443 participants were analyzed. Twenty-two cases developed preeclampsia (5.0%) and seven of these preeclamptic cases had early-onset preeclampsia (1.6%). Pregnant women with preeclampsia had higher mean PI of the uterine artery (1.34 ± 0.52 vs 0.98 ± 0.28, p = 0.004), higher detection rates of diastolic notching (45.5% vs 11.2%, p < 0.001), and lower median serum micro RNA-210 level (22.86 vs 795.78, p < 0.001) than pregnant women without preeclampsia. Using abnormal serum micro RNA-210 level, abnormal mean PI or uterine artery diastolic notches to predict for preeclampsia, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 95.5%, 54.9%, 10.0%, and 99.6%, respectively. For early-onset preeclampsia prediction, the sensitivity, specificity, PPV, and NPV were 100.0%, 53.2%, 3.3%, and 100.0%, respectively. This study demonstrated that a combination of serum micro RNA-210 and uterine artery Doppler is effective in predicting preeclampsia in the second trimester.


2019 ◽  
Vol 90 (e7) ◽  
pp. A2.3-A3
Author(s):  
Hue Mun Au Yong ◽  
Erica Minato ◽  
Eldho Paul ◽  
Udaya Seneviratne

IntroductionThis study aims to (i)evaluate the diagnostic sensitivity, specificity and predictive values of seizure-related heart rate (HR) in differentiating epileptic seizures(ES) from psychogenic non-epileptic seizures(PNES), (ii)define the most useful point of HR measurement: pre-ictal, ictal-onset, maximal-ictal or post-ictal, and (iii)define the HR cut-off points to differentiate ES from PNES.MethodsAll video EEG(VEEG) at Monash Health from May 2009 to November 2015 were retrospectively reviewed. Baseline(during wakefulness), one-minute pre-ictal, ictal-onset, maximal-ictal and one-minute post-ictal HR were measured for each ES and PNES event. Events less than ten seconds or with uninterpretable ECG due to artefacts were excluded. ROC curve analysis was performed to study the diagnostic accuracy reflected by area under the curve(AUC). The AUC was interpreted as follows; ≤0.5, differentiation of PNES from ES no better than chance; 0.80–0.89, good differentiation; and 0.9–1, excellent differentiation.ResultsVEEG of 341 ES and 265 PNES from 130 patients were analysed. The AUC for pre-ictal, ictal-onset, maximal-ictal and post-ictal HR were found to have poor differentiation between ES and PNES. Comparing PNES and bilateral tonic-clonic ES, AUC for absolute maximal-ictal HR was 0.84(CI 0.73–0.95) and for absolute post-ictal HR was 0.90(CI 0.81–1.00). Using Youden’s index, to diagnose tonic-clonic ES, the optimal cut-off point for absolute maximal-ictal HR was 114bpm (sensitivity 84%;specificity 82%;PPV 26.7%,NPV 98.5%) and for absolute post-ictal HR was 90bpm(sensitivity 91%;specificity 82%;PPV 30.3%;NPV 99.1%).ConclusionsThese findings suggest that seizure-related HR increase is useful in differentiating bilateral tonic-clonic ES from PNES. Based on the AUC, the best diagnostic measureme.


Sign in / Sign up

Export Citation Format

Share Document