scholarly journals 006 Can seizure-related heart rate differentiate epileptic seizures from psychogenic non-epileptic seizures?

2019 ◽  
Vol 90 (e7) ◽  
pp. A2.3-A3
Author(s):  
Hue Mun Au Yong ◽  
Erica Minato ◽  
Eldho Paul ◽  
Udaya Seneviratne

IntroductionThis study aims to (i)evaluate the diagnostic sensitivity, specificity and predictive values of seizure-related heart rate (HR) in differentiating epileptic seizures(ES) from psychogenic non-epileptic seizures(PNES), (ii)define the most useful point of HR measurement: pre-ictal, ictal-onset, maximal-ictal or post-ictal, and (iii)define the HR cut-off points to differentiate ES from PNES.MethodsAll video EEG(VEEG) at Monash Health from May 2009 to November 2015 were retrospectively reviewed. Baseline(during wakefulness), one-minute pre-ictal, ictal-onset, maximal-ictal and one-minute post-ictal HR were measured for each ES and PNES event. Events less than ten seconds or with uninterpretable ECG due to artefacts were excluded. ROC curve analysis was performed to study the diagnostic accuracy reflected by area under the curve(AUC). The AUC was interpreted as follows; ≤0.5, differentiation of PNES from ES no better than chance; 0.80–0.89, good differentiation; and 0.9–1, excellent differentiation.ResultsVEEG of 341 ES and 265 PNES from 130 patients were analysed. The AUC for pre-ictal, ictal-onset, maximal-ictal and post-ictal HR were found to have poor differentiation between ES and PNES. Comparing PNES and bilateral tonic-clonic ES, AUC for absolute maximal-ictal HR was 0.84(CI 0.73–0.95) and for absolute post-ictal HR was 0.90(CI 0.81–1.00). Using Youden’s index, to diagnose tonic-clonic ES, the optimal cut-off point for absolute maximal-ictal HR was 114bpm (sensitivity 84%;specificity 82%;PPV 26.7%,NPV 98.5%) and for absolute post-ictal HR was 90bpm(sensitivity 91%;specificity 82%;PPV 30.3%;NPV 99.1%).ConclusionsThese findings suggest that seizure-related HR increase is useful in differentiating bilateral tonic-clonic ES from PNES. Based on the AUC, the best diagnostic measureme.

2020 ◽  
Vol 163 (6) ◽  
pp. 1156-1165
Author(s):  
Juan Xiao ◽  
Qiang Xiao ◽  
Wei Cong ◽  
Ting Li ◽  
Shouluan Ding ◽  
...  

Objective To develop an easy-to-use nomogram for discrimination of malignant thyroid nodules and to compare diagnostic efficiency with the Kwak and American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS). Study Design Retrospective diagnostic study. Setting The Second Hospital of Shandong University. Subjects and Methods From March 2017 to April 2019, 792 patients with 1940 thyroid nodules were included into the training set; from May 2019 to December 2019, 174 patients with 389 nodules were included into the validation set. Multivariable logistic regression model was used to develop a nomogram for discriminating malignant nodules. To compare the diagnostic performance of the nomogram with the Kwak and ACR TI-RADS, the area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values were calculated. Results The nomogram consisted of 7 factors: composition, orientation, echogenicity, border, margin, extrathyroidal extension, and calcification. In the training set, for all nodules, the area under the curve (AUC) for the nomogram was 0.844, which was higher than the Kwak TI-RADS (0.826, P = .008) and the ACR TI-RADS (0.810, P < .001). For the 822 nodules >1 cm, the AUC of the nomogram was 0.891, which was higher than the Kwak TI-RADS (0.852, P < .001) and the ACR TI-RADS (0.853, P < .001). In the validation set, the AUC of the nomogram was also higher than the Kwak and ACR TI-RADS ( P < .05), each in the whole series and separately for nodules >1 or ≤1 cm. Conclusions When compared with the Kwak and ACR TI-RADS, the nomogram had a better performance in discriminating malignant thyroid nodules.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2009 ◽  
Vol 67 (3b) ◽  
pp. 789-791 ◽  
Author(s):  
Gisele R. de Oliveira ◽  
Francisco de A.A. Gondim ◽  
Edward R. Hogan ◽  
Francisco H. Rola

Heart rate changes are common in epileptic and non-epileptic seizures. Previous studies have not adequately assessed the contribution of motor activity on these changes nor have evaluated them during prolonged monitoring. We retrospectively evaluated 143 seizures and auras from 76 patients admitted for video EEG monitoring. The events were classified according to the degree of ictal motor activity (severe, moderate and mild/absent) in: severe epileptic (SE, N=17), severe non-epileptic (SNE, N=6), moderate epileptic (ME, N=28), moderate non-epileptic (MNE, N=11), mild epileptic (mE, N=35), mild non-epileptic (mNE, N=33) and mild aura (aura, N=13). Heart rate increased in the ictal period in severe epileptic, severe non-epileptic, moderate epileptic and mild epileptic events (p<0.05). Heart rate returned to baseline levels during the post ictal phase in severe non-epileptic seizures but not in severe epileptic patients. Aura events had a higher baseline heart rate. A cut-off of 20% heart rate increase may distinguish moderate epileptic and mild epileptic events lasting more than 30 seconds. In epileptic seizures with mild/absent motor activity, the magnitude of heart rate increase is proportional to the event duration. Heart rate analysis in seizures with different degrees of movement during the ictal phase can help to distinguish epileptic from non-epileptic events.


2012 ◽  
Vol 5 (1) ◽  
pp. 31 ◽  
Author(s):  
Flávio Pivatelli ◽  
Marcio dos Santos ◽  
Gislaine Fernandes ◽  
Marcio Gatti ◽  
Luiz de Abreu ◽  
...  

2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Anupam Kumar Singh ◽  
Amit Lohia

Background. FEV1/FEV6 has been proposed as a cheap, reproducible and valid alternative to FEV1/FVC in spirometry. No Indian data exists on its utility to diagnose airway obstruction. Aim. we sought to determine a fixed cut off of FEV1/FEV6 to diagnose obstruction corresponding to FEV1/FVC < 0.70 proposed by GOLD guidelines. Method. Spirometry was done on patient referred to a tertiary centre in India. Age, sex, height weight were recorded in addition to spirometric variables like FEV1, FVC, FEV6. The sensitivity, specificity, positive and negative predictive values of FEV1/FEV6 were determined with respect to gold standard of FEV1/FVC < 0.70. Results. 467 spirometries were analysed after meeting the ATS acceptability criteria. Considering FEV1/FVC < 0.7 as being the gold standard for obstruction, ROC curve was used to determine the best corresponding cut-off for FEV1/FEV6. The area under the curve was 99.3% (95% CI: 98.1–99.8%), and the FEV1/FEV6 cut-off, corresponding to the greatest sum of sensitivity and specificity, was 73%. For the total population, the FEV1/FEV6 sensitivity, specificity, PPV, NPV were was 95.7 %, 94.2 %, 87.5 % and 97.9 % respectively. Agreement by Kappa value between two cut offs was excellent 0.89 (0.87–0.91). Conclusion. FEV1/FEV6 < 73% is a new reliable spirometry index to diagnose airway obstruction in Indian population.


2016 ◽  
Vol 33 (12) ◽  
pp. 656-662
Author(s):  
Joy Mammen ◽  
Jui Choudhuri ◽  
Joshua Paul ◽  
Thomas Isaiah Sudarsan ◽  
T. Josephine ◽  
...  

Background: The diagnosis of sepsis is challenging in the absence of a gold standard test. Recent studies have explored the role of neutrophil and monocyte volume, conductivity, and scatter (VCS), derived from automated hematology analyzers, in diagnosing sepsis. We assessed the diagnostic accuracy of VCS parameters in critically ill patients with sepsis. Methodology: In this prospective study, VCS parameters, procalcitonin, and C-reactive protein (CRP) were assessed in patients with proven sepsis (cases) and 2 control groups (intensive care unit [ICU] patients without sepsis and healthy blood donors). The diagnostic property of each test was explored by calculating sensitivity, specificity, negative and positive predictive values, and area under the curve (AUC). Results: The study included 65 patients with sepsis, 58 nonseptic ICU controls, and 98 blood donors. Procalcitonin and CRP were not significantly different ( P > .06) between patients with sepsis and nonseptic patients. Mean (95% confidence interval [CI]) neutrophil volume (MNV) was significantly higher ( P < .001) in patients with sepsis (165.5; 95%CI 161.6-169.4) than in nonseptic (157.3; 95%CI 154.6-160.1) patients and donors (148.9; 95%CI 147.9-150). A similar pattern was seen with mean monocyte volume (MMoV). Neutrophil and monocyte conductivity and scatter parameters were variably associated. The AUC was highest for MMoV (0.74) and lowest for CRP (0.62). Among all parameters, MNV and MMoV had the highest specificity of 85% and 80%, respectively. Conclusion: In critically ill patients with suspected sepsis, VCS parameters may help strengthen the diagnostic probability of sepsis. Future studies may explore the role of serial monitoring of VCS to track response to antimicrobial therapy.


Author(s):  
Slobodanka Beatovic ◽  
Marija Radulovic ◽  
Otas Durutovic ◽  
Milos Veljkovic ◽  
Jelena Saponjski ◽  
...  

Introduction/Objective. Nuclear Medicine Section of IAEA has developed the software for dynamic renal scintigraphy, which allows calculation of advanced parameters of drainage: renal output efficiency (OE) and normalized residual activity (NORA). The aim of this study was to validate IAEA software by comparing results of parameters of renal drainage in normal subjects against their established reference values and to assess diagnostic accuracy of OE and NORA in distinguishing between obstruction/unobstruction. Methods. 55 patients with suspected obstruction and 36 kidney donors were investigated. Group A consisted of 24 obstructed kidneys, Group B of 37 kidneys with dilated urinary tract and Group C of 72 normal kidneys. 40min acquisition was applied. Furosemide was administered after 20min. Post-micturition image was acquired at 50min. Parameters analyzed were: OE at 20min (OE20) and at the end of furosemide test (OE40), NORA at 20min (NORA20) and after micturition (NORAPM). One-way ANOVA was used for evaluating differences between Groups. Ability of OE40 and NORAPM to distinguish between obstruction/unobstruction was determined by ROC curve analysis. The sensitivity, specificity, area under the curve and cutoff values were analyzed. Results. Excellent agreement of our results with established OE and NORA values was found. Difference between Groups was significant for OE20, OE40 NORA20 and NORAPM (p < 0.001). Cut-off values for obstruction were 82% and 0.11 for OE40 and NORAPM, respectively. Conclusion. IAEA software gives reliable analysis of diuretic renography and helps to better diagnose obstruction. IAEA should be encouraged to produce final version of the software and to release it through Web site.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Line Thorndal Moll ◽  
Anne Mette Schmidt ◽  
Christina Malmose Stapelfeldt ◽  
Merete Labriola ◽  
Ole Kudsk Jensen ◽  
...  

Abstract Background In cases of neck and shoulder pain, the responsibility for assessing work prognosis is held by clinicians with access to different domains of information. One of these domains is magnetic resonance imaging (MRI), and although MRI is increasingly used, it is unknown which domains of information contribute the most to the prediction of work prognosis. This retrospective cohort study explored the contribution of demographic, patient-reported, clinical, and MRI information to the prediction of work participation in sickness absentees with neck or shoulder pain. Methods From a secondary care setting, 168 sickness absentees with neck or shoulder pain were included. Based on registry data, a successful work outcome was defined as ≥50% work participation score (WPS) from Weeks 1 to 104 after enrolment. Prognostic variables were categorized into four domains (demographic, patient-reported, clinical, and MRI) resembling the order of information obtained in a clinical setting. Crude logistic regression analyses were used to identify prognostic variables for each domain (p < 0.2). This was followed by multivariable analyses including the identified variables in a domain-wise order. For each added domain, the probability of successful WPS was dichotomized leaving two possible classifications: ≥ 50% chance of successful WPS or not. In cross-tabulations of chance and the actual WPS outcome, positive and negative predictive values (PPV and NPV), sensitivity, specificity and area under the curve (AUC) were calculated. Results The combination of demographic and patient-reported variables yielded an NPV of 0.72 and a PPV of 0.67, while specificity was 0.82, sensitivity 0.54 and AUC 0.77. None of these values improved notably by adding clinical and MRI variables as predictors of successful WPS. Conclusions These results suggest that - among sickness absentees with neck or shoulder pain – clinical and MRI variables provide no additional information for the prediction of work participation compared with only demographic and patient-reported information.


2019 ◽  
Vol 36 (6) ◽  
pp. 530-538
Author(s):  
Nicolò Tamini ◽  
Davide Paolo Bernasconi ◽  
Luca Gianotti

Aim of the Study: The diagnosis of choledocholithiasis is challenging. Previously published scoring systems designed to calculate the risk of choledocholithiasis were evaluated to appraise the diagnostic performance. Patients and Methods: Data of patients who were admitted between 2013 and 2015 with the following characteristics were retrieved: bile stone-related symptoms and signs, and indication to laparoscopic cholecystectomy. To validate and appraise the performance of the 6 scoring systems, the acknowledged domains of each metrics were applied to the present cohort. Sensitivity, specificity, positive, negative predictive, Youden index, and receiver operating characteristic curve with the area under the curve (AUC) values of the scores were calculated. Results: Two-hundred patients were analyzed. The highest sensitivity and specificity were obtained from the Menezes’ (96.6%) and Telem’s (99.3%) metrics respectively. The Telem’s and Menezes’ scores had the best positive (75.0%) and negative (96.4%) predictive values respectively. The best accuracy, as computed by the Youden index and AUC, was found for the Soltan’s scoring system (0.628 and 0.88, respectively). Conclusion: The available scoring systems are precise only in identifying patients with a negligible risk of common bile duct stone, but overall insufficiently accurate to suggest the routine use in clinical practice.


2007 ◽  
Vol 65 (3a) ◽  
pp. 565-568 ◽  
Author(s):  
Gisele R. de Oliveira ◽  
Francisco de A.A. Gondim ◽  
R. Edward Hogan ◽  
Francisco H. Rola

The distinction of non-epileptic from epileptic events is difficult even for experienced neurologists. We retrospectively evaluated 59 dialeptic events from 27 patients admitted for video EEG monitoring to check whether heart rate (HR) analysis could help in differentiating dialeptic complex partial temporal lobe seizures (TLS) from dialeptic simple partial TLS, and non-epileptic dialeptic events. Baseline HR was increased in the simple partial TLS in comparison to complex partial TLS and non-epileptic groups (p<0.05). HR increase accompanied each individual dialeptic complex partial TLS (100% of the events, p<0.05) bur HR returned to baseline in the post-ictal phase. Ictal HR was not altered in the non-epileptic or simple partial TLS groups. Our findings suggest that ictal centrally mediated tachycardia is characteristic of dialeptic TLS (both tachycardia and bradycardia have been reported during TLS). This finding may be used as a criterion to distinguish dialeptic complex partial TLS from simple partial and non-epileptic dialeptic events.


Sign in / Sign up

Export Citation Format

Share Document