A sample preparation and microprobe x-ray imaging method for histological localization of cisplatin

Author(s):  
G.R. Hook

Cis-diamminedichloroplatinuum II (CDDP or cisplatin) is a chemotherapeutic drug used to treat cancers of the testicals, ovaries, head, neck and bladder. Although the histological distribution of cisplatin may provide important information on the drug's affect, the cisplatin histological distribution has not been determined because suitable sample preparation and analytical methods have not been developed. We describe here a sample preparation and analytical method to image cisplatin at histological resolution within rat abdominal wall tissue.

2007 ◽  
Vol 204 (8) ◽  
pp. 2734-2739 ◽  
Author(s):  
K. Mizuno ◽  
Y. Furuya ◽  
K. Hirano ◽  
H. Okamoto

MRS Bulletin ◽  
1988 ◽  
Vol 13 (1) ◽  
pp. 13-18 ◽  
Author(s):  
J.H. Kinney ◽  
Q.C. Johnson ◽  
U. Bonse ◽  
M.C. Nichols ◽  
R.A. Saroyan ◽  
...  

Imaging is the cornerstone of materials characterization. Until the middle of the present century, visible light imaging provided much of the information about materials. Though visible light imaging still plays an extremely important role in characterization, relatively low spatial resolution and lack of chemical sensitivity and specificity limit its usefulness.The discovery of x-rays and electrons led to a major advance in imaging technology. X-ray diffraction and electron microscopy allowed us to characterize the atomic structure of materials. Many materials vital to our high technology economy and defense owe their existence to the understanding of materials structure brought about with these high-resolution methods.Electron microscopy is an essential tool for materials characterization. Unfortunately, electron imaging is always destructive due to the sample preparation that must be done prior to imaging. Furthermore, electron microscopy only provides information about the surface of a sample. Three dimensional information, of great interest in characterizing many new materials, can be obtained only by time consuming sectioning of an object.The development of intense synchrotron light sources in addition to the improvements in solid state imaging technology is revolutionizing materials characterization. High resolution x-ray imaging is a potentially valuable tool for materials characterization. The large depth of x-ray penetration, as well as the sensitivity of absorption crosssections to atomic chemistry, allows x-ray imaging to characterize the chemistry of internal structures in macroscopic objects with little sample preparation. X-ray imaging complements other imaging modalities, such as electron microscopy, in that it can be performed nondestructively on metals and insulators alike.


Author(s):  
David Mascali ◽  
Eugenia Naselli ◽  
Richard Racz ◽  
Sándor Biri ◽  
Luigi Celona ◽  
...  

Abstract We hereby report the study of confinement and electron losses dynamics in the magnetic trap of an Electron Cyclotron Resonance Ion Source (ECRIS) using a special multi-diagnostic setup that has allowed the simultaneous collection of plasma radio-self-emission and X-ray images in the range 500 eV - 20 keV. Argon plasmas were generated in single and two close frequency heating (TCFH) modes. Evidences of turbulent regimes have been found: for stable and unstable configurations quantitative characterizations of the plasma radio self-emission have been carried out, then compared with local measurement of plasma energy content evaluated by X-ray imaging. This imaging method is the only one able to clearly separate X-ray radiation coming from the plasma from the one coming from the plasma chamber walls. X-ray imaging has been also supported and benchmarked by volumetric spectroscopy performed via SDD and HPGe detectors. The obtained results in terms of X-ray intensity signal coming from the plasma core and from the plasma chamber walls have permitted to estimate the average ratio: plasma vs. walls (i.e., plasma losses) as a function of input RF power and pumping wave frequency, showing an evident increase (above the experimental errors) of the intensity in the 2-20 keV energy range due to the plasma losses in case of unstable plasma. This ratio was well correlated with the strength of the instabilities, in single frequency heating (SFH) operation mode; in TCFH mode, under specific power balance conditions and frequency combinations, it was possible to damp the instabilities, thus the plasma losses were observed to decrease and a general reconfiguration of the spatial plasma structure occurred (the X-ray emission was more concentrated in the center of the plasma chamber). In the end, a simplified model has been used to simulate electron heating under different pumping frequencies, discussing the impact of velocity anisotropy vs. the onset of the instability, and the mechanism of particles diffusion in the velocity space in stable and unstable regimes.


Molecules ◽  
2020 ◽  
Vol 25 (22) ◽  
pp. 5297
Author(s):  
Kayla M. Billiard ◽  
Amanda R. Dershem ◽  
Emanuela Gionfriddo

Implementing green analytical methodologies has been one of the main objectives of the analytical chemistry community for the past two decades. Sample preparation and extraction procedures are two parts of analytical method development that can be best adapted to meet the principles of green analytical chemistry. The goal of transitioning to green analytical chemistry is to establish new methods that perform comparably—or superiorly—to traditional methods. The use of assessment tools to provide an objective and concise evaluation of the analytical methods’ adherence to the principles of green analytical chemistry is critical to achieving this goal. In this review, we describe various sample preparation and extraction methods that can be used to increase the greenness of a given analytical method. We gave special emphasis to modern microextraction technologies and their important contributions to the development of new green analytical methods. Several manuscripts in which the greenness of a solid-phase microextraction (SPME) technique was compared to other sample preparation strategies using the Green Analytical Procedure Index (GAPI), a green assessment tool, were reviewed.


2018 ◽  
Vol 33 (7) ◽  
pp. 1264-1268 ◽  
Author(s):  
Ignacio Machado ◽  
Sebastián Mondutey ◽  
Natalia Pastorino ◽  
Valeria Arce ◽  
Mariela Pistón

A simple, fast and environmentally friendly method for sample preparation and subsequent determination of minerals in wheat flour using TXRF.


2021 ◽  
Vol 16 (08) ◽  
pp. P08037
Author(s):  
C.H. Lim ◽  
J. Lee ◽  
Y. Choi ◽  
J.W. Park ◽  
H.K. Kim

2014 ◽  
Vol 87 (7) ◽  
pp. 278-283
Author(s):  
Naoya AMINO ◽  
Yasuhiro ISHIKAWA ◽  
Masaki SATO
Keyword(s):  
X Ray ◽  

Sign in / Sign up

Export Citation Format

Share Document