Use of non-thermal atmospheric plasmas to reduce the viability ofBacillus subtilison spacecraft surfaces

2008 ◽  
Vol 7 (1) ◽  
pp. 47-57 ◽  
Author(s):  
Andrew C. Schuerger ◽  
Steven Trigwell ◽  
Carlos I. Calle

AbstractAtmospheric pressure glow-discharge (APGD) plasmas have been proposed for sterilizing spacecraft surfaces prior to launch. The advantages of APGD plasmas for the sterilization of spacecraft surfaces include low temperatures at treatment sites, rapid inactivation kinetics of exposed microbial cells, physical degradation and removal of microbial cells, physical removal of organic biosignature molecules, and short exposure times for the materials. However, few studies have tested APGD plasmas on spacecraft materials for their effectiveness in both sterilizing surfaces and removal of microbial cells or spores. A helium (He)+oxygen (O2) APGD plasma was used to expose six spacecraft materials (aluminum 6061, polytetrafluoroethylene (PTFE), polycarbonate, Saf-T-Vu, Rastex, and Herculite 20) doped with spores of the common spacecraft contaminant,Bacillus subtilis, for periods of time up to 6 min. Results indicated that greater than six orders of magnitude reductions in viability were observed forB. subtilisspores in as short of time as 40 s exposure to the APGD plasmas. Spacecraft materials were not affected by exposures to the APGD plasmas. However, Saf-T-Vu was the only material in which spores ofB. subtilisadhered more aggressively to plasma-treated coupons when compared to non-plasma treated coupons; all other materials exhibited no significant differences between plasma and non-plasma treated coupons. In addition, spores ofB. subtiliswere physically degraded by exposures to the plasmas beginning at the terminal ends of spores, which appeared to be ruptured after only 30 s. After 300 s, most bacteria were removed from aluminium coupons, and only subtle residues of bacterial secretions or biofilms remained. Results support the conclusion that APGD plasmas can be used as a prelaunch cleaning and sterilization treatment on spacecraft materials provided that the biocidal and cleaning times are shorter than those required to alter surface properties of materials.

2000 ◽  
Vol 63 (10) ◽  
pp. 1404-1409 ◽  
Author(s):  
HIROSHI FUJIKAWA ◽  
SATOSHI MOROZUMI ◽  
GLEN H. SMERAGE ◽  
ARTHUR A. TEIXEIRA

Characteristics of capillary and test tube procedures for thermal inactivation kinetic analysis of microbial cells were studied for mold spores. During heating, capillaries were submerged in a water bath and test tubes were held with their caps positioned above the level of the heating medium. Thermal inactivation curves of Aspergillus niger spores in capillaries at around 60°C consisted of a shoulder and a fast linear decline, whereas curves in test tubes consisted of a shoulder, a fast linear decline, and a horizontal tail. There were no significant differences in values of the rate and the delay of fast declines in curves between the procedures. Some experiments were done to clarify the cause for tailing with test tubes. There were no tails with test tubes whose inner walls were not contaminated by A. niger spores, suggesting that tails arise from A. niger spores contaminating the inner walls of test tubes. Temperature of the inner wall at the level of a heating medium was lower than that of the medium. Further, there were no tails for test tubes submerged in the heating medium. These results showed that the reason for survival of contaminants on the upper wall of test tubes was that cells were not subjected to sufficient inactivation temperature. Finally, thermal inactivation curves of A. niger spores in capillaries at various constant temperatures were studied. Curves consisted of a shoulder and a fast linear decline at 57°C and above, whereas curves at below 57°C consisted of a shoulder, a fast linear decline, and a sloping tail.


2003 ◽  
Vol 79 (10) ◽  
pp. 1002-1008 ◽  
Author(s):  
Koichi TAKAKI ◽  
Tamiya FUJIWARA ◽  
Fumiyoshi TOCHIKUBO

LWT ◽  
2021 ◽  
Vol 142 ◽  
pp. 111037
Author(s):  
Leonardo do Prado-Silva ◽  
Verônica O. Alvarenga ◽  
Gilberto Ú.L. Braga ◽  
Anderson S. Sant’Ana

Author(s):  
Monika Gorska ◽  
Pawel Pohl

Atmospheric pressure glow discharge (APGD) microplasma, sustained between a flowing liquid cathode (FLC) and a tungsten anode, was applied for the determination of Ca, K, Mg, and Na in fruit juices with a simplified sample preparation procedure.