scholarly journals Effect of sutureless securement on hemodialysis catheter-related bloodstream infection

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Keiji Fujimoto ◽  
Emi Iida ◽  
Syo Kumano ◽  
Ai Fujii ◽  
Hiroki Adachi ◽  
...  

AbstractThe use of sutureless securement devices during catheterization might reduce the risk of catheter-related bloodstream infection (CRBSI) by suppressing catheter-exit infection and catheter dislodgement. However, the effectiveness of these devices in reducing CRBSI risk when securing hemodialysis catheters has not been explored. This single-center retrospective observational study examined 211 non-tunneled hemodialysis catheters (NTHCs) from 110 hemodialysis inpatients, of which 121 were secured using conventional skin sutures (Suture group) and 90 with GRIP-LOK (GRIP-LOK group). The stabilized inverse probability of treatment (SIPT)-weighting method was used to generate a new population (SIPT-weighted model) without group differences for each of the 12 predictors of CRBSI development (i.e., age, sex, dialysis history, concomitant acute kidney injury or diabetes, concurrent use of immunosuppressant drugs or aspirin, NTHC insertion site, methicillin-resistant Staphylococcus aureus, carriage, bacteremia event within 3 months before catheterization, hemoglobin level, and serum albumin titer). The effect of GRIP-LOK compared with sutures on CRBSI in the SIPT-weighted model was evaluated using univariate SIPT-weighted Cox proportional regression analysis, which showed a significant CRBSI suppression effect of GRIP-LOK compared with sutures (hazard ratio: 0.17 [95% CI 0.04–0.78], p = 0.023). GRIP-LOK affords a lower risk of CRBSI due to indwelling NTHCs than conventional securement using sutures.

2020 ◽  
Vol 7 (6) ◽  
Author(s):  
Kylie Martin ◽  
Yves S Poy Lorenzo ◽  
Po Yee Mia Leung ◽  
Sheri Chung ◽  
Emmet O’flaherty ◽  
...  

Abstract Diabetes and left internal jugular vein insertion site were significantly associated with increased risk of a catheter-related bloodstream infection from a tunneled hemodialysis catheter. Ex-smoker status was significantly associated with reduced risk.


2021 ◽  
Vol 30 (14) ◽  
pp. S24-S32
Author(s):  
Matthias Alexander Neusser ◽  
Irina Bobe ◽  
Anne Hammermeister ◽  
Udo Wittmann

HIGHLIGHTS 2% taurolidine catheter lock solution without additives is safe and efficient. CRBSI and dysfunction rates compare favorably against other studies in hemodialysis Background: In hemodialysis patients, catheter-related bloodstream infection (CRBSI) and catheter dysfunction are common and cause significant morbidity, mortality, and costs. Catheter lock solutions reduce CRBSI and catheter dysfunction rates, but solutions containing heparin, citrate, or antibiotics are associated with adverse effects. Due to its antimicrobial and antithrombotic properties and benign safety profile, taurolidine is suitable for use in catheter lock solutions. In this study the effectiveness and safety of a catheter lock solution containing 2% taurolidine without citrate or heparin (TauroSept®, Geistlich Pharma AG, Wolhusen, Switzerland) in hemodialysis patients were investigated for the first time. Methods: Data from 21 patients receiving chronic hemodialysis via tunneled central venous catheters with 2% taurolidine solution as a catheter lock were analyzed in a single-center retrospective study and compared with the existing literature in a review. The primary endpoint was CRBSI rate. Secondary endpoints included catheter dysfunction, treatment, and costs; catheter technical problems, resolution, and costs; and adverse events. Data were compared to outcomes with standard lock solutions in the literature. Results: No CRBSIs occurred during the observation period of 5,639 catheter days. The catheter dysfunction rate was 0.71 per 1,000 catheter days, and the catheter dysfunction treatment costs were CHF (Swiss Franc) 543 per patient. No technical problems or adverse events related to the use of 2% taurolidine-containing catheter lock solution were observed. These results compare favorably with other catheter lock solutions. Conclusions: A solution containing 2% taurolidine seems suitable as a hemodialysis catheter lock. In a Swiss cohort, it prevented CRBSI, limited catheter dysfunction, and was cost-efficient.


2020 ◽  
Vol 93 (5) ◽  
pp. 227-233
Author(s):  
Camille Roger ◽  
Nathalie Maisonneuve ◽  
Laurie Ferret ◽  
Christian Cattoen ◽  
Thomas Quemeneur ◽  
...  

Author(s):  
Tatsuya Kobayashi ◽  
Mahoko Ikeda ◽  
Yuki Ohama ◽  
Koji Murono ◽  
Kazuhiko Ikeuchi ◽  
...  

Abstract Background Staphylococcus schleiferi is a gram-positive pathogenic coccus which causes canine skin and ear infections. Only four cases of human infection caused by Staphylococcus schleiferi subspecies coagulans have been reported. Herein, we present the first case of catheter-related bloodstream infection caused by S. schleiferi subspecies coagulans. Case presentation A 62-year-old Japanese man was admitted to our hospital for examination of sigmoid colon tumor. During hospitalization, he had fever, shaking chills, and swelling at the peripheral venous catheter insertion site. Two sets of blood cultures were positive for S. schleiferi subspecies coagulans which was confirmed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), 16S ribosomal RNA sequencing and the coagulase test. The patient was successfully treated without relapse. Conclusion To our knowledge, this is the first report of catheter-related bloodstream infection caused by S. schleiferi subspecies coagulans. S. schleiferi subsp. coagulans can be pathogenic in humans, and MALDI-TOF MS can contribute to accurate identification of S. schleiferi subspecies coagulans.


Sign in / Sign up

Export Citation Format

Share Document