scholarly journals Clinical Outcomes and Risk Factors for Tunneled Hemodialysis Catheter-Related Bloodstream Infections

2020 ◽  
Vol 7 (6) ◽  
Author(s):  
Kylie Martin ◽  
Yves S Poy Lorenzo ◽  
Po Yee Mia Leung ◽  
Sheri Chung ◽  
Emmet O’flaherty ◽  
...  

Abstract Diabetes and left internal jugular vein insertion site were significantly associated with increased risk of a catheter-related bloodstream infection from a tunneled hemodialysis catheter. Ex-smoker status was significantly associated with reduced risk.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Keiji Fujimoto ◽  
Emi Iida ◽  
Syo Kumano ◽  
Ai Fujii ◽  
Hiroki Adachi ◽  
...  

AbstractThe use of sutureless securement devices during catheterization might reduce the risk of catheter-related bloodstream infection (CRBSI) by suppressing catheter-exit infection and catheter dislodgement. However, the effectiveness of these devices in reducing CRBSI risk when securing hemodialysis catheters has not been explored. This single-center retrospective observational study examined 211 non-tunneled hemodialysis catheters (NTHCs) from 110 hemodialysis inpatients, of which 121 were secured using conventional skin sutures (Suture group) and 90 with GRIP-LOK (GRIP-LOK group). The stabilized inverse probability of treatment (SIPT)-weighting method was used to generate a new population (SIPT-weighted model) without group differences for each of the 12 predictors of CRBSI development (i.e., age, sex, dialysis history, concomitant acute kidney injury or diabetes, concurrent use of immunosuppressant drugs or aspirin, NTHC insertion site, methicillin-resistant Staphylococcus aureus, carriage, bacteremia event within 3 months before catheterization, hemoglobin level, and serum albumin titer). The effect of GRIP-LOK compared with sutures on CRBSI in the SIPT-weighted model was evaluated using univariate SIPT-weighted Cox proportional regression analysis, which showed a significant CRBSI suppression effect of GRIP-LOK compared with sutures (hazard ratio: 0.17 [95% CI 0.04–0.78], p = 0.023). GRIP-LOK affords a lower risk of CRBSI due to indwelling NTHCs than conventional securement using sutures.


2021 ◽  
pp. 112972982110270
Author(s):  
Michael G Tal ◽  
Alexander S Yevzlin

Background: Tunneled hemodialysis catheter-related bloodstream infection is a major cause of morbidity and mortality in end-stage renal disease patients. Side holes positioned near the tip of catheters have been linked to formation of thrombi, which, in turn, have been implicated in predisposition to infection. In addition, side holes allow spillage of catheter locking solution, including antibiotics, thereby minimizing the lock solution’s effect on the catheter tip. This study assessed the infection events that occurred in a series of hemodialysis patients using a non-side-hole catheter. Methods: Over a period of 2 years, a novel symmetric-tip non-side-hole catheter was placed in 60 patients. Hemodialysis was performed thrice weekly. Prescribed dialyzer flows were 300–350 mL/min. Catheters were routinely locked with heparin 5000 units/mL between treatments. Patients were followed up for any catheter related complications, specifically infection events. Results: Seven events of catheter-related bloodstream infection occurred for a rate of 0.76 events per 1000 catheter-days, with the first event occurring 9 weeks after insertion. These events were treated by locking the affected catheter with 2 g of clindamycin in 2 mL of heparin 1000 units/mL and administration of intravenous antibiotics, in most cases, for 7–14 days. Two catheters were removed due to infection. Conclusions: Catheter-related bloodstream infections with non-side-hole hemodialysis catheters do occur at a relatively low rate and in this initial preliminary study it seems that most of these infections can be successfully treated without removal of the affected catheters.


2009 ◽  
Vol 30 (7) ◽  
pp. 698-701 ◽  
Author(s):  
Stefania Bezzio ◽  
C. Scolfaro ◽  
R. Broglia ◽  
R. Calabrese ◽  
F. Mignone ◽  
...  

This prospective observational study was designed to assess the incidence of, risk factors for, and outcome of catheter-related bloodstream infection in children undergoing cardiac surgery. A staff specifically trained to handle the central venous catheters with proper aseptic techniques and an appropriate patient to medical staff ratio remain the most effective measures to prevent this infection.


2008 ◽  
Vol 65 (1) ◽  
pp. 21-26 ◽  
Author(s):  
Radojica Stolic ◽  
Goran Trajkovic ◽  
Vladan Peric ◽  
Aleksandar Jovanovic ◽  
Dragica Stolic ◽  
...  

Backgraund/Aim. Hemodialysis catheter, as an integral part of hemodialysis, is a catheter placed into the jugular, subclavian and femoral vein. The most common catheter-related complications are infections and thrombosis. The aim of the study was to analyze the prevalence of complications associated with differently inserted central-vein catheters for hemodialysis. Methods. The study was organized as a prospective examination during the period from December 2003 to November 2006, and included all patients who needed an active depuration by hemodialysis, hospitalized at the Clinical Center Kragujevac. The subject of the study were 464 centralvein catheters inserted during the mentioned period and there were recorded all complications related to the placement and usage of catheters. Results. The largest percent of inserted catheters was into the femoral vein ? 403 (86.8%), significantly less into the jugular vein ? 42 (9.2%), while into the subclavian vein there were placed only 19 catheters (4%). The average of femoral catheter functioning was 17 catheter days, in jugular catheters it was 17.3 days while the subclavian catheters had an average rate of functioning of 25.9 catheter days; there was found a statistically significant difference regarding the duration of functioning (p = 0.03). By microbe colonization of smear culture of the skin at the catheter insertion site, in clinically present suspicion of catheter infection, there was obtained a positive finding in 5.5% of catheters placed into the femoral vein and 7.1% of catheters instilled into the jugular vein, of which Staphylococcus aureus was the most important bacterial type, without statistically significant difference (p = 0.51). Haemoculture, done when there was a suspicion of bacteriemia, was positive in 3.7% of the patients with femoral and 4.8% with jugular catheters; Staphylococcus aureus was the most common bacteria type, but there was no statistically significant difference (p = 0.65). Colonizing the smears of the cut catheter tops, there was found a positive finding in 8.9% of femoral and 4.7% of jugular catheters in which the mentioned type of staphylococcal bacteria was prevalent, without statistically significant difference (p = 0.82). In 77% of femoral, 71.4% of jugular and 68.4% of subclavian catheters, there were no complications associated with insertion and manipulation of catheters for hemodialysis and the difference was at the limits of statistical significance (p = 0.06). Conclusion. Unconvincing rate of infections and a smaller percent of serious complications associated with the placement and use of central vein catheters instilled into the femoral vein, indicate that personal experience is sufficient recommendation to convince us that femoral vein does not represent a region with an increased risk for insertion of hemodialysis catheters.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S401-S401
Author(s):  
Jack McHugh ◽  
Talha Khawaja ◽  
Larry M Baddour ◽  
Larry M Baddour ◽  
Juan Crestanello ◽  
...  

Abstract Background Bloodstream infections (BSIs) confer an increased risk of infective endocarditis (IE) in patients with a prosthetic cardiac valve. This relationship is less well established in patients undergoing valve repair. We conducted a retrospective population-based study to determine the incidence of BSIs following valve repair and identify risk factors associated with the development of IE. Methods The Rochester Epidemiology Project (REP) data linkage system was used to identify all persons who underwent valve repair in a 7-county region in Southeastern Minnesota between January 1, 2010 and December 31, 2018. Medical records were screened for the development of a BSI from time of procedure until May 15, 2020. Patients were classified as having BSI only, BSI with IE at outset, or BSI with subsequent development of new IE. IE at outset was defined as cases where IE was diagnosed at the time of initial positive blood culture. Results A total of 387 patients underwent valve repair surgery. A total of 31 (8%) patients subsequently developed a BSI, 4% within one year of surgery. Seventeen patients underwent mitral repair with annuloplasty, 9 underwent tricuspid annuloplasty, and 5 had concurrent repairs. Median time to the development of BSI was 338 days. Of the 31 patients with BSI, 4 (13%) had BSI with IE at outset. No patients developed IE subsequent to BSI, Enterococcus spp. was responsible for 3 cases of IE, and MSSA for 1. All cases occurred within one year of surgery. Given the low incidence, statistical analysis of associated risk factors for IE was not feasible. All patients with BSI and IE at outset, however, died by the end of the study period, versus 11/27 in the BSI only group. Conclusion Incidence of BSIs was higher in patients undergoing cardiac valve repair than in the general population. The incidence of IE with a BSI was 13%, which is lower than what has been previously published. It is notable that all cases of IE occurred within one year of surgery. Recognizing that endothelialization of device surfaces occurs, it is tempting to speculate that the risk of IE may be time dependent and may decline over time. Subsequent investigation of this theory is underway. Disclosures Larry M. Baddour, MD, Boston Scientific (Consultant)


2014 ◽  
Vol 36 (2) ◽  
pp. 214-216 ◽  
Author(s):  
Devin Callister ◽  
Pauline Limchaiyawat ◽  
Samantha J. Eells ◽  
Loren G. Miller

Little is known about central line–associated bloodstream infection risk factors in the bundle era. In our case-control investigation, we found that independent risk factors for central line–associated bloodstream infection at our center included the number of recent lab tests, catheter duration, and lack of hemodynamic monitoring as the insertion indication.Infect Control Hosp Epidemiol 2014;00(0): 1–3


2021 ◽  
Vol 30 (14) ◽  
pp. S24-S32
Author(s):  
Matthias Alexander Neusser ◽  
Irina Bobe ◽  
Anne Hammermeister ◽  
Udo Wittmann

HIGHLIGHTS 2% taurolidine catheter lock solution without additives is safe and efficient. CRBSI and dysfunction rates compare favorably against other studies in hemodialysis Background: In hemodialysis patients, catheter-related bloodstream infection (CRBSI) and catheter dysfunction are common and cause significant morbidity, mortality, and costs. Catheter lock solutions reduce CRBSI and catheter dysfunction rates, but solutions containing heparin, citrate, or antibiotics are associated with adverse effects. Due to its antimicrobial and antithrombotic properties and benign safety profile, taurolidine is suitable for use in catheter lock solutions. In this study the effectiveness and safety of a catheter lock solution containing 2% taurolidine without citrate or heparin (TauroSept®, Geistlich Pharma AG, Wolhusen, Switzerland) in hemodialysis patients were investigated for the first time. Methods: Data from 21 patients receiving chronic hemodialysis via tunneled central venous catheters with 2% taurolidine solution as a catheter lock were analyzed in a single-center retrospective study and compared with the existing literature in a review. The primary endpoint was CRBSI rate. Secondary endpoints included catheter dysfunction, treatment, and costs; catheter technical problems, resolution, and costs; and adverse events. Data were compared to outcomes with standard lock solutions in the literature. Results: No CRBSIs occurred during the observation period of 5,639 catheter days. The catheter dysfunction rate was 0.71 per 1,000 catheter days, and the catheter dysfunction treatment costs were CHF (Swiss Franc) 543 per patient. No technical problems or adverse events related to the use of 2% taurolidine-containing catheter lock solution were observed. These results compare favorably with other catheter lock solutions. Conclusions: A solution containing 2% taurolidine seems suitable as a hemodialysis catheter lock. In a Swiss cohort, it prevented CRBSI, limited catheter dysfunction, and was cost-efficient.


2019 ◽  
Vol 147 ◽  
Author(s):  
Wei Zhang ◽  
Xingpeng Song ◽  
Hao Wu ◽  
Rui Zheng

Abstract This study aimed to evaluate the clinical characteristics, risk factors and outcomes of adult patients with candidaemia caused by C. albicans vs. non-albicans Candida spp. (NAC). All adult hospitalised cases of candidaemia (2012–2017) at a tertiary hospital in Shenyang were included in the retrospective study, and a total of 180 episodes were analysed. C. parapsilosis was the most frequently isolated species (38.3%), followed by C. albicans (35.6%), C. glabrata (13.9%), C. tropicalis (10%) and others (2.2%). As initial antifungal therapy, 75.0%, 3.9%, 5.6% and 2.2% of patients received fluconazole, caspofungin, micafungin and voriconazole, respectively. Multivariate analyses revealed that total parenteral nutrition was associated with an increased risk of NAC bloodstream infections (BSI) (OR 2.535, 95% CI (1.066–6.026)) vs. C. albicans BSI. Additionally, the presence of a urinary catheter was associated with an increased risk of C. albicans BSI (OR 2.295 (1.129–4.666)) vs. NAC BSI. Moreover, ICU stay (OR 4.013 (1.476–10.906)), renal failure (OR 3.24 (1.084–9.683)), thrombocytopaenia (OR 7.171 (2.152–23.892)) and C. albicans (OR 3.629 (1.352–9.743)) were independent risk factors for candidaemia-related 30-day mortality, while recent cancer surgery was associated with reduced mortality risk (OR 26.479 (2.550–274.918)). All these factors may provide useful information to select initial empirical antifungal agents.


2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Ouni Amal ◽  
Meriem Ben salem ◽  
Malek Mojaat ◽  
Hadj Brahim Mayssa ◽  
Ben salah Manel ◽  
...  

Abstract Background and Aims the recourse to catheter among patients on hemodialysis is frequent due to many reasons. It is highly associated to a risk of infection in comparison to AVF. The aim of our study was to determine the clinical and bacteriological parameters in patients hospitalized for dialysis catheter related bloodstream infections. Method We conducted a retrospective descriptive study based on the data of patients hospitalized for hemodialysis catheter-related bloodstream infection in the department of nephrology in Fattouma Bourguiba University hospital between January 2013 and February 2018. Data concerning the bacteriological exams were obtained from our bacteriology laboratory. Results 50 patients were included with a mean-age of 56 years old. 74% were women, 30% diabetic and 18% considered immunodepressed. The indications for the placement of catheter were: 21 patients waiting for the creation of AVF, 16 patients with a dysfunction of AVF, 6 patients with AKI and 7 patients with inadequate veins for the creation of AFV. The IJV was the site of insertion in 74% of patients (with 4 % of tunneled catheters). 26 % of patients developed a septic choc, and 74 % developed a sepsis. The culture of the specimen of catheters was positive in 32 patients (64%). Staphylococcus aureus was isolated in 14 patients (28%) with MSSA among 8 patients and enterobacteria among 8 patients. Hemoculture was only positive in 13 patients. The catheter was removed in the majority of cases except in 6 patients in whom there was no other venous access. The evolution was favourable in 80 % of patients. 5 patients developed an infective endocarditis as a secondary localization. Conclusion The AVF remains the best vascular access for hemopadialysis patients. The recourse to catheters must be considered as a last choice because of the risk of infections which frequently necessitates the hospitalization with an increase in mortality.


Sign in / Sign up

Export Citation Format

Share Document