A modified field test for the determination of carbon disulphide vapour in air

The Analyst ◽  
1973 ◽  
Vol 98 (1169) ◽  
pp. 585 ◽  
Author(s):  
E. C. Hunt ◽  
W. A. McNally ◽  
A. F. Smith
Keyword(s):  
1983 ◽  
Vol 48 (3) ◽  
pp. 722-734
Author(s):  
Martin Koval

The flame ionisation detector response to C6-C11 aliphatic hydrocarbon solutions in carbon disulphide in the concentration range between 1.3-9.5 mg ml-1 retained lineary despite the excess of solvent entering the detector simultaneously with the analyte. Pure carbon disulphide exhibited a small positive detector response which did not interfere in calibration procedure and which, under certain GC conditions, inverted to negative values. This response was not proportional to the injected volume and was strongly influenced by the column temperature and/or bleed. On the basis of these findings, a method compatible with the widely used charcoal tube carbon disulphide desorption procedure was developed and evaluated. It consists of static desorption of the sum of aliphatic alkanes and cycloalkanes from the activated charcoal after which an internal standard is added to the supernatant eluate. The resulting carbon disulphide solution is analysed on a highly polar stationary phase 1,2,3-tris(2-cyanoethoxy)propane where the solvent and the analyte coelute in a single peak, the height of which is practically proportional to the sum of alkanes and cycloalkanes present. This also makes determinations of other substances present in the sample more simple. The field test of the proposed method yielded values comparable in precision and accuracy with a control infrared spectrophotometric method.


2021 ◽  
pp. 027112142098171
Author(s):  
Michael D. Toland ◽  
Jennifer Grisham ◽  
Misti Waddell ◽  
Rebecca Crawford ◽  
David M. Dueber

Rasch and classification analyses on a field-test version of the Assessment, Evaluation, and Programming System Test—Third Edition (AEPS-3), a curriculum-based assessment used to assess young children birth to age 6 years, were conducted. First, an evaluation of the psychometric properties of data from each developmental area of an AEPS-3 field-test version was conducted. Next, cutoff scores at 6-month age intervals were created and then the validity of the cutoff scores was evaluated. Results using Rasch modeling indicated acceptable model fit statistics with reasonable reliability estimates within each developmental area. Classification results showed cutoff scores accurately classified a high percentage of eligible children. Findings suggest that scores from a field-test version of the AEPS-3 are reliable within developmental areas. To the extent allowed by state criteria, early childhood interventionists could possibly use a new field-test version of the AEPS-3 to determine or corroborate eligibility for special education services.


Author(s):  
Klaus Brun ◽  
Rainer Kurz

Field testing of gas turbine compressor packages requires the accurate determination of efficiency, capacity, head, power and fuel flow in sometimes less than ideal working environments. Nonetheless, field test results have significant implication for the compressor and gas turbine manufacturers and their customers. Economic considerations demand that the performance and efficiency of an installation are verified to assure a project’s return on investment. Thus, for the compressor and gas turbine manufacturers, as well as for the end-user, an accurate determination of the field performance is of vital interest. This paper describes an analytic method to predict the measurement uncertainty and, thus, the accuracy, of field test results for gas turbine driven compressors. Namely, a method is presented which can be employed to verify the validity of field test performance results. The equations governing the compressor and gas turbine performance uncertainties are rigorously derived and results are numerically compared to actual field test data. Typical field test measurement uncertainties are presented for different sets of instrumentation. Test parameters that correlate to the most significant influence on the performance uncertainties are identified and suggestions are provided on how to minimize their measurement errors. The effect of different equations of state on the calculated performance is also discussed. Results show that compressor efficiency uncertainties can be unacceptably high when some basic rules for accurate testing are violated. However, by following some simple measurement rules and maintaining commonality of the gas equations of state, the overall compressor package performance measurement uncertainty can be limited and meaningful results can be achieved.


1982 ◽  
Vol 52 (4) ◽  
pp. 869-873 ◽  
Author(s):  
F. Conconi ◽  
M. Ferrari ◽  
P. G. Ziglio ◽  
P. Droghetti ◽  
L. Codeca

The relationship between running speed (RS) and heart rate (HR) was determined in 210 runners. On a 400-m track the athletes ran continuously from an initial velocity of 12–14 km/h to submaximal velocities varying according to the athlete's capability. The HRs were determined through ECG. In all athletes examined, a deflection from the expected linearity of the RS-HR relationship was observed at submaximal RS. The test-retest correlation for the velocities at which this deflection from linearity occurred (Vd) determined in 26 athletes was 0.99. The velocity at the anaerobic threshold (AT), established by means of blood lactate measurements, and Vd were coincident in 10 runners. The correlation between Vd and average running speed (mean RS) in competition was 0.93 in the 5,000 m (mean Vd = 19.13 +/- 1.08 km/h; mean RS = 20.25 +/- 1.15 km/h), 0.95 in the marathon (mean Vd = 18.85 +/- 1.15 km/h; mean RS = 17.40 +/- 1.14 km/h), and 0.99 in the 1-h race (mean Vd = 18.70 +/- 0.98 km/h; mean RS = 18.65 +/- 0.92 km/h), thus showing that AT is critical in determining the running pace in aerobic competitive events.


Soil Research ◽  
1989 ◽  
Vol 27 (4) ◽  
pp. 673 ◽  
Author(s):  
EA Close ◽  
HKJ Powell

A field test is described for determination of 0.02 M CaC12 extractable ('soluble') aluminium in soils. The method uses a 5 min extraction (2 min shaking followed by 3 min settling period). An aliquot of extract is then added to the metallochromic reagent chrome azurol S, CAS (amber). Aluminium reacts rapidly with CAS in hexamine buffer (pH 4.9) to form a 1 : 1 complex, Al(CAS) (purple). Intermediate colours arise in solutions where CAS is partly converted to the aluminium complex. The developed colour may be compared visually (or spectrophotometricaliy in the laboratory) with standards. Alternatively the CAS concentration may be selected to give the purple colour at a predetermined concentration of aluminium in the extractant solution, corresponding to the toxicity threshold for a specific crop and soil. CAS-reactive Al (5 min extraction) was correlated with total Al (1 h extraction; AAS) soluble in 0.02 M CaCl2, by Alt = 1.62[CAS-Al]+0.5 for soils with Alt < 60 mg kg-1 (n = 22; r2 = 0.99).


Sign in / Sign up