Influence of gold nanoparticle size (2–50 nm) upon its electrochemical behavior: an electrochemical impedance spectroscopic and voltammetric study

2011 ◽  
Vol 13 (11) ◽  
pp. 4980 ◽  
Author(s):  
Alessandra Bonanni ◽  
Martin Pumera ◽  
Yuji Miyahara

2021 ◽  
Vol 23 (2) ◽  
Author(s):  
Subhan Shaik ◽  
Aarthi Saminathan ◽  
Deepak Sharma ◽  
Jagdish A Krishnaswamy ◽  
D Roy Mahapatra


2002 ◽  
Vol 756 ◽  
Author(s):  
H. Zhang ◽  
X. Ma ◽  
J. Dai ◽  
S. Hui ◽  
J. Roth ◽  
...  

ABSTRACTAn intermediate temperature solid oxide fuel cell (SOFC) electrolyte film of La0.8Sr 0.2Ga0.8Mg0.2O2.8 (LSGM) was fabricated using a plasma spray process. The microstructure and phase were investigated using X-ray diffraction (XRD) and scanning electron microscopy (SEM). The electrochemical behavior of the thermal sprayed LSGM film was investigated using electrochemical impedance spectroscopy (EIS). The study indicates that thermal spray can deposit a dense LSGM layer. It was found that the rapid cooling in the thermal process led to an amorphous or poor crystalline LSGM deposited layer. This amorphous structure has a significant effect on the performance of the cell. Crystallization of the deposited LSGM layer was observed during annealing between 500–600 °C. After annealing at 800 °C, the ionic conductivity of the sprayed LSGM layer can reach the same level as that of the sintered LSGM.





2016 ◽  
Vol 931 ◽  
pp. 47-56 ◽  
Author(s):  
Libu Manjakkal ◽  
Katarina Cvejin ◽  
Jan Kulawik ◽  
Krzysztof Zaraska ◽  
Robert P. Socha ◽  
...  


2019 ◽  
Vol 63 (1) ◽  
Author(s):  
Mehdi Jalali ◽  
Zeinab Deris Falahieh ◽  
Mohammad Alimoradi ◽  
Jalal Albadi ◽  
Ali Niazi

The electrochemical behavior of Bi+3 ions on the surface of a glassy carbon electrode, in acidic media and in the presence of tamoxifen, was investigated. Cyclic voltammetry, chronoamperometry, differential pulse voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy were used to find the probable mechanism contributing to the reduction of the peak height of bismuth oxidation with an increase in the concentration of tamoxifen. The obtained results show a slight interaction between the bismuth species and tamoxifen which co-deposit on the surface of glassy carbon electrode. Therefore, the reduction in the peak height of bismuth oxidation as a function of tamoxifen concentration was used to develop a new differential pulse anodic striping voltammetry method for determination of trace amount of tamoxifen. The effects of experimental parameters on the in situ DPASV of Bi+3 ions in the presence of tamoxifen shown the optimal conditions as: 2 mol L-1 H2SO4 (1% v v-1 MeOH), a deposition potential of -0.5 V, a deposition time of 60 s, and a glassy carbon electrode rotation rate of 300 rpm. The calibration curve was plotted in the range of 0.5 to 6 µg mL-1 and the limits of detection and quantitation were calculated to be 3.1 × 10-5 µg mL-1 and 1.0 × 10-4 µg mL-1, respectively. The mean, RSD, and relative bias for 0.5 µg mL-1 (n=5) were found to be 0.49 µg mL-1, 0.3%, and 2%, respectively. Finally, the proposed method was successfully used for the determination of tamoxifen in serum and pharmaceutical samples.



2020 ◽  
Vol 20 (10) ◽  
pp. 6235-6244 ◽  
Author(s):  
A. Murugan ◽  
V. Siva ◽  
A. Shameem ◽  
S. Asath Bahadur

The Cu2ZnSnS4 (CZTS) thin films have been prepared at different deposition cycles, deposited on a glass substrate by successive ionic layer adsorption and reaction (SILAR) method followed by the annealing process at elevated temperature. The investigations on the films have been carried out to understand and confirm its structure, functional group present, crystalline morphology, optical and electrochemical behavior. The powder X-ray diffraction patterns recorded indicate that the deposited films are formed in the tetragonal structure. Other parameters like grain size, dislocation density, and microstrain are also calculated. The uniform surface of the films with spherical shaped morphology has been observed by Scanning Electron Microscopy, and the elemental compositions have been confirmed by EDAX. Electrochemical behavior such as cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charge–discharge analysis have been carried out by electrochemical workstation. The modified electrode exhibits maximum specific capacitance value as 416 F/g for a pure sample. Optical studies have shown that the band gaps are estimated between 1.40 eV and 1.57 eV.



CORROSION ◽  
10.5006/3254 ◽  
2019 ◽  
Vol 75 (11) ◽  
pp. 1339-1353
Author(s):  
Maryam Eslami ◽  
Flavio Deflorian ◽  
Caterina Zanella

The electrochemical behavior of a low silicon aluminum alloy cast by the conventional and rheo-high-pressure die cast processes is evaluated using polarization test and electrochemical impedance spectroscopy in 0.01 M, 0.05 M, 0.1 M, and 0.6 M sodium chloride solutions. Compared to the conventional high-pressure die cast process, rheocasting introduces some alterations in the microstructure including the presence of aluminum grains with different sizes, formed at different solidification stages. According to the results of the anodic polarization test, conventional cast and rheocast samples show similar breakdown potentials. However, the rheocast samples present enhanced oxygen reduction kinetics compared to the conventional cast sample. Based on scanning electron microscopy examinations, localized microgalvanic corrosion is the main corrosion mechanism for both alloys and it initiates at the interface of aluminum with iron-rich intermetallic particles which are located inside the eutectic regions. The corrosion further develops into the eutectic area. Although the rate of the cathodic reaction can be influenced by the semisolid microstructure, according to the results of anodic polarization and electrochemical impedance spectroscopy tests, the corrosion behavior is not meaningfully affected by the casting process.



Sign in / Sign up

Export Citation Format

Share Document