Depth dependent element ratios in fluid inclusion analysis by laser ablation ICP-MS

2012 ◽  
Vol 27 (3) ◽  
pp. 505 ◽  
Author(s):  
Marcel Guillong ◽  
Thomas Pettke
2004 ◽  
Vol 68 (1) ◽  
pp. 31-46 ◽  
Author(s):  
J. Zachariáš ◽  
J. Frýda ◽  
B. Paterová ◽  
M. Mihaljevič

AbstractThe major- and trace-element chemistry of pyrite and arsenopyrite from the mesothermal Roudný gold deposits was studied by electron microprobe and laser ablation ICP-MS techniques. In total, four generations of pyrite and two of arsenopyrite were distinguished. The pyrite is enriched in As through an Fe (AsxS1–x)2 substitution mechanism. The As-rich zones of pyrite-2 (up to 4.5 wt.% As) are also enriched in gold (up to 20 ppm), lead (commonly up to 220 ppm, exceptionally up to 1500 ppm) and antimony (commonly <600 ppm, rarely up to 1350 ppm). Positive correlation of As and Au in the studied pyrites is not coupled with an Fe deficiency, in contrast to Au-rich As-bearing pyrites in Carlintype gold deposits. The As-rich pyrite-2 coprecipitated with the Sb-rich (1 –4.2 wt.%) and Au-rich (40 –150 ppm) arsenopyrite-1. The younger arsenopyrite-2 is significantly less enriched in these elements (0 –70 ppm of Au).The chemical zonality of pyrites in the Roudný gold deposits reflects the chemical evolution of orebearing fluids that are not observed in any other mineral phases. The data available suggest relatively high activity of sulphur and low activities of arsenic and gold during crystallization of the older pyrite generation (pyrite-1). Later, after particular dissolution of pyrite-1, Au-rich As-bearing pyrite-2 and arsenopyrite precipitated. These facts suggest a marked increase in the arsenic and gold activities in ore-bearing fluids. The As-content of pyrite-2 decreases in an oscillatory manner from the core to the rim, reflecting changes in the As activity or/and in the P-T conditions. The As-bearing pyrites were formed at temperatures of at least 320–330°C, based on arsenopyrite thermometers and fluid inclusion data.


2014 ◽  
Vol 29 (6) ◽  
pp. 1052-1057 ◽  
Author(s):  
M. Wälle ◽  
C. A. Heinrich

The performance of a sector field ICP-MS in comparison with a quadrupole ICP-MS for fluid inclusion analysis has been evaluated.


2017 ◽  
Author(s):  
Amy K. Plechacek ◽  
◽  
Madeline E. Schreiber ◽  
John A. Chermak ◽  
Tracy L. Bank

Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 77
Author(s):  
Davide Spanu ◽  
Gilberto Binda ◽  
Marcello Marelli ◽  
Laura Rampazzi ◽  
Sandro Recchia ◽  
...  

A laser ablation–inductively coupled plasma–mass spectrometry (LA–ICP–MS) based method is proposed for the quantitative determination of the spatial distribution of metal nanoparticles (NPs) supported on planar substrates. The surface is sampled using tailored ablation patterns and the data are used to define three-dimensional functions describing the spatial distribution of NPs. The volume integrals of such interpolated surfaces are calibrated to obtain the mass distribution of Ag NPs by correlation with the total mass of metal as determined by metal extraction and ICP–MS analysis. Once this mass calibration is carried out on a sacrificial sample, quantifications can be performed over multiple samples by a simple micro-destructive LA–ICP–MS analysis without requiring the extraction/dissolution of metal NPs. The proposed approach is here tested using a model sample consisting of a low-density polyethylene (LDPE) disk decorated with silver NPs, achieving high spatial resolution over cm2-sized samples and very high sensitivity. The developed method is accordingly a useful analytical tool for applications requiring both the total mass and the spatial distribution of metal NPs to be determined without damaging the sample surface (e.g., composite functional materials and NPs, decorated catalysts or electrodic materials).


Author(s):  
Andrew Kataba ◽  
Shouta M. M. Nakayama ◽  
Hokuto Nakata ◽  
Haruya Toyomaki ◽  
Yared B. Yohannes ◽  
...  

Lead (Pb) is a metal toxicant of great public health concern. The present study investigated the applicability of the rat incisor in Pb exposure screening. The levels of lead in teeth (Pb-T) in the crown and root of incisors in laboratory Pb-exposed Sprague Dawley rats were quantified using inductively coupled plasma mass spectrometry (ICP-MS). The crown accumulated much Pb-T than the root of the Sprague Dawley rat incisor. The levels of lead in blood (Pb-B) were positively correlated with the Pb-T in the crown and root incisors of the Sprague Dawley rats. As an application of the Pb-T crown results in experimental rats, we subsequently analyzed the Pb-T in the crown incisors of Pb-exposed wild rats (Rattus rattus) sampled from residential sites within varying distances from an abandoned lead–zinc mine. The Pb-T accumulation in the crown of incisors of R. rattus rats decreased with increased distance away from the Pb–Zn mine. Furthermore, the Pb-T was strongly correlated (r = 0.85) with the Pb levels in the blood. Laser ablation ICP-MS Pb-T mappings revealed a homogenous distribution of Pb in the incisor with an increased intensity of Pb-T localized in the tip of the incisor crown bearing an enamel surface in both Sprague Dawley and R. rattus rats. These findings suggest that Pb-T in the crown incisor may be reflective of the rat’s environmental habitat, thus a possible indicator of Pb exposure.


Sign in / Sign up

Export Citation Format

Share Document