PAHs in animal tissues – the analytics of PAHs in new reference materials and their homogeneity

2017 ◽  
Vol 9 (1) ◽  
pp. 76-83 ◽  
Author(s):  
Anna Kiełbasa ◽  
Bogusław Buszewski

Extraction and determination of PAHs in biological matrices of new reference materials, and determination of certified values and homogeneity of these materials are described.

1982 ◽  
Vol 65 (3) ◽  
pp. 647-650 ◽  
Author(s):  
Gerard K H Tam ◽  
Gladys Lacroix

Abstract A dry ashing, flameless atomic absorption spectrometric method was evaluated to determine arsenic and selenium in foods. Samples were dry-ashed with Mg(N03)2-MgO and dissolved in HC1. Selenate was reduced to selenite by boiling in 4N HC1, and arsenate to arsenite by treatment with KI. Hydrides of arsenic and selenium were generated by the addition of NaBH4 and were swept by nitrogen and hydrogen into a thermally heated silicate tube furnace. The detection limit was about 5 ppb for each element based on a 10 g sample. Analytical results obtained for several samples of NBS reference materials agreed with the certified values. The procedure was evaluated by another laboratory and results were satisfactory.


1985 ◽  
Vol 68 (2) ◽  
pp. 218-220
Author(s):  
Craig D Salisbury ◽  
Wayne Chan

Abstract A simple, automated wet digestion procedure was developed for the quantitative determination by atomic absorption spectroscopy (AAS) of arsenic, cadmium, copper, mercury, lead, selenium, and zinc in animal tissue. A commercial digestion block system with automated temperature programming was used. Recoveries of all elements from spiked bovine liver and kidney samples exceed 95%. The analytical results obtained for samples of NBS Bovine Liver (No. 1577a) agree well with certified values. The procedure is safe and requires minimum analyst time.


2019 ◽  
Vol 107 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Iga Zuba ◽  
Halina Polkowska-Motrenko

Abstract Primary reference measurement procedure for Cr determination in biological samples by radiochemical neutron activation analysis (RNAA) has been elaborated. The procedure is based on quantitative and selective separation of chromium from neutron irradiated sample by column chromatography using MnO2-Resin and determination of 51Cr by γ-ray spectrometry. Quality components have been incorporated into the RNAA method which makes it possible to meet the requirements of the definition of ratio primary reference measurement procedure. The usefulness of the elaborated procedure to assign the certified values for Cr in new certified reference material (CRMs) based on animal tissues is demonstrated. The tentative certified values for Cr have been proposed for: MODAS M-4 Cormorant Tissue and M-5 Cod Tissue CRMs.


Author(s):  
Federico Fanti ◽  
Eleonora Oliva ◽  
Daniel Tortolani ◽  
Camilla Di Meo ◽  
Marina Fava ◽  
...  
Keyword(s):  

1953 ◽  
Vol 201 (2) ◽  
pp. 609-613 ◽  
Author(s):  
Wanda E. Taylor ◽  
J.M. McKibbin
Keyword(s):  

Author(s):  
Isabel Abad-Álvaro ◽  
Diego Leite ◽  
Dorota Bartczak ◽  
Susana Cuello ◽  
Beatriz Gomez-Gomez ◽  
...  

Toxicological studies concerning nanomaterials in complex biological matrices usually require a carefully designed workflow that involves handling, transportation and preparation of a large number of samples without affecting the nanoparticle...


Sign in / Sign up

Export Citation Format

Share Document