A new rapid treatment of human hair for elemental determination by inductively coupled mass spectrometry

2020 ◽  
Vol 12 (14) ◽  
pp. 1906-1918 ◽  
Author(s):  
Maria Luisa Astolfi ◽  
Carmela Protano ◽  
Elisabetta Marconi ◽  
Lorenzo Massimi ◽  
Marco Brunori ◽  
...  

Advancements in sample preparation for performing elemental analysis are coming from the dissemination of microwave-assisted procedures, but there is still room for improvements by looking for fast and easily applicable procedures.

2017 ◽  
Vol 32 (8) ◽  
pp. 1500-1507 ◽  
Author(s):  
Jorge Moreda-Piñeiro ◽  
Alicia Cantarero-Roldán ◽  
Antonio Moreda-Piñeiro ◽  
José Ángel Cocho ◽  
Pilar Bermejo-Barrera

An approach by laser ablation (LA) coupled with inductively coupled mass spectrometry (ICP-MS) for multi-element determination in whole blood is described.


2015 ◽  
Vol 98 (1) ◽  
pp. 160-164 ◽  
Author(s):  
Nancy Morris Hepp

Abstract Specifications in the Code of Federal Regulationslimit the levels of As, Pb, and Hg in most certifiable color additives, and some have additional specification limits for Cr and Mn. A new ICP/MS method wasdeveloped and validated for the quantitative determination of these elements in various certifiable color additives. One dissolution and two microwave-assisted digestion sample preparation procedures were optimized to address initial low Hg and enhanced As recoveries. Results using the three sample preparation procedures were generally equivalent for all of the elements determined. LOQ values were 0.3 mg/kg for As, 0.7 mg/kg for Cr, 0.4 mg/kg for Pb, 0.7 mg/kg forMn, and 0.1 mg/kg for Hg.


2010 ◽  
Vol 75 (6) ◽  
pp. 803-812 ◽  
Author(s):  
Snezana Kravic ◽  
Zvonimir Suturovic ◽  
Jaroslava Svarc-Gajic ◽  
Zorica Stojanovic ◽  
Mira Pucarevic

A sample preparation method based on the simultaneous microwave-assisted extraction-esterification (SMAEE) was developed for the determination of the fatty acid composition of foodstuffs by gas chromatography-mass spectrometry. The proposed sample preparation method was validated by comparison with the reference Soxhlet extraction method followed by derivatisation by ester formation and the same determination step. The fatty acid compositions and the extraction efficiencies obtained using the proposed SMAEE method and the reference method were statistically similar. The results showed that compared to the conventional method, the SMAEE method offered the advantages of short sample preparation time, low consumption of expensive organic solvents and lower energy consumption. This good agreement between results provided by both the SMAEE and the reference method demonstrates the usefulness of the former as a routine method for the treatment of food samples prior to trans fatty analysis.


Sign in / Sign up

Export Citation Format

Share Document