A analysis method for system frequency modulation capacity considering the influences of large scale wind power

Author(s):  
Lv Jian-fang ◽  
Cui Zheng-pai ◽  
Sheng Si-qing ◽  
Wang Jing-ran ◽  
Wu Lin-lin
2013 ◽  
Vol 58 (36) ◽  
pp. 4557-4565 ◽  
Author(s):  
HaiShun Sun ◽  
Ju Liu ◽  
JinYu Wen ◽  
ShiJie Cheng ◽  
Cheng Luo ◽  
...  

2013 ◽  
Vol 291-294 ◽  
pp. 407-414 ◽  
Author(s):  
Guo Peng Zhou ◽  
Fu Feng Miao ◽  
Xi Sheng Tang ◽  
Tao Wu ◽  
Shan Ying Li ◽  
...  

The output power of wind farms has significant randomness and variability, which results in adverse impacts on power system frequency stability. This paper extracts wind power fluctuation feature with the HHT (Hilbert-Huang Transform) method. Firstly, the original wind power data was decomposed into several IMFs (Intrinsic Mode Functions) and a tendency component by using the EMD (Empirical Mode Decomposition) method. Secondly, the instantaneous frequency of each IMF was calculated. On this basis, taking a WSCC 9-bus power system as benchmark, the impact on power system frequency caused by wind power fluctuation was simulated in a real-time simulation platform, and the key component which results in the frequency deviation was found. The simulation results validate the wind power fluctuation impacts on frequency deviation, underlying the following study on power system frequency stability under the situation of large-scale intermittent generation access into the grid.


Author(s):  
Chao Wang ◽  
Jianyuan Xu ◽  
Liang Wang ◽  
Dan Song

Abstract The increasing global energy and environmental problems are encouraging to the development and utilization of renewable and clean energy in various countries. Wind power is one of the major source in large-scale renewable energy applications. However, the frequency regulation becomes a critical issue while the technology is spreading. Research on the frequency modulation (FM) technology of wind turbines and its control strategy for future power grids become significant. The paper proposes a novel coordinated frequency control strategy with the synchronous generator to solve the unmatched state between the output power of the doubly-fed wind turbines (doubly-fed induction generators) and the grid frequency, combined with the frequency response characteristics of the synchronous generator. The FM coordination strategy is formulated by the modulation coefficient from current wind speed and operation mode of each wind turbine. By coordinating the FM output of the doubly-fed wind turbine and the synchronous generator within the allowable range of frequency deviation, it will achieve the dual goal of reducing the frequency regulation pressure of the synchronous generator and indirectly reducing the abandoned wind volume of the wind turbine. The simulation is carried out on the MATLAB/SIMULINK platform. The results show that the presenting variable coefficient frequency modulation strategy could significant smooth the wind power fluctuation, and allow the reserve power of the doubly-fed wind turbine can fully engaged in frequency modulation which will reduces the frequency modulation pressure of the synchronous generator in the system.


Energy ◽  
2021 ◽  
Vol 228 ◽  
pp. 120642
Author(s):  
Evangelos G. Tsimopoulos ◽  
Michael C. Georgiadis

2014 ◽  
Vol 2014 (10) ◽  
pp. 538-545 ◽  
Author(s):  
Abdul Basit ◽  
Anca Daniela Hansen ◽  
Mufit Altin ◽  
Poul Sørensen ◽  
Mette Gamst

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2287
Author(s):  
Kaina Qin ◽  
Shanshan Wang ◽  
Zhongjian Kang

With the rapid increase in the proportion of the installed wind power capacity in the total grid capacity, the state has put forward higher and higher requirements for wind power integration into the grid, among which the most difficult requirement is the zero-voltage ride through (ZVRT) capability of the wind turbine. When the voltage drops deeply, a series of transient processes, such as serious overvoltage, overcurrent, or speed rise, will occur in the motor, which will seriously endanger the safe operation of the wind turbine itself and its control system, and cause large-scale off-grid accident of wind generator. Therefore, it is of great significance to improve the uninterrupted operation ability of the wind turbine. Doubly fed induction generator (DFIG) can achieve the best wind energy tracking control in a wide range of wind speed and has the advantage of flexible power regulation. It is widely used at present, but it is sensitive to the grid voltage. In the current study, the DFIG is taken as the research object. The transient process of the DFIG during a fault is analyzed in detail. The mechanism of the rotor overcurrent and DC bus overvoltage of the DFIG during fault is studied. Additionally, the simulation model is built in DIgSILENT. The active crowbar hardware protection circuit is put into the rotor side of the wind turbine, and the extended state observer and terminal sliding mode control are added to the grid side converter control. Through the cooperative control technology, the rotor overcurrent and DC bus overvoltage can be suppressed to realize the zero-voltage ride-through of the doubly fed wind turbine, and ensure the safe and stable operation of the wind farm. Finally, the simulation results are presented to verify the theoretical analysis and the proposed control strategy.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 474
Author(s):  
Junxi Wang ◽  
Qi Jia ◽  
Gangui Yan ◽  
Kan Liu ◽  
Dan Wang

With the development of large-scale new energy, the wind–thermal bundled system transmitted via high-voltage direct current (HVDC) has become the main method to solve the problem of wind power consumption. At the same time, the problem of subsynchronous oscillation among wind power generators, high-voltage direct current (HVDC), and synchronous generators (SGs) has become increasingly prominent. According to the dynamic interaction among doubly fed induction generators (DFIGs), HVDC, and SGs, a linearization model of DFIGs and SGs transmitted via HVDC is established, and the influence of the electromagnetic transient of wind turbines and HVDC on the electromechanical transient processes of SGs is studied. Using the method of additional excitation signal injection, the influence of the main factors of DFIG on the damping characteristics of each torsional mode of SG is analyzed, including control parameters and operation conditions when the capacity of HVDC is fixed. The mechanism of the negative damping torsional of SGs is identified. A time-domain simulation model is built in Electromagnetic Transients including DC/Power Systems Computer Aided Design (EMTDC/PSCAD) to verify the correctness and effectiveness of the theoretical analysis.


Sign in / Sign up

Export Citation Format

Share Document