Expanding EV Charging Capacity in Distribution Networks: A Case Study for Charging EVs at Work

2021 ◽  
Author(s):  
O. Alatise ◽  
A. Karlsson ◽  
A. Deb ◽  
R. Wu ◽  
J. Ortiz-Gonzalez
Author(s):  
Nguyen Thu Ha ◽  
Nguyen Thi Thanh Huyen

The retail market in Vietnam continues to grow with the entry of foreign retail brands and the strong rise of domestic businesses in expanding distribution networks and conquering consumer confidence. The appearance of more retail brands has created a fiercely competitive market. Based on the outcomes of previous research results on brand choice intention combined with a customer survey, the paper proposes an analytical framework and scales to examine the relationship of five elements including store image, price perception, risk perception, brand attitudes, brand awareness and retail brand choice intention with a case study of the Hanoi-based Circle K convenience store chain. These five elements are the precondition for retail businesses to develop their brands so as to attract customers.


Author(s):  
Aly-Joy Ulusoy ◽  
Filippo Pecci ◽  
Ivan Stoianov

AbstractThis manuscript investigates the design-for-control (DfC) problem of minimizing pressure induced leakage and maximizing resilience in existing water distribution networks. The problem consists in simultaneously selecting locations for the installation of new valves and/or pipes, and optimizing valve control settings. This results in a challenging optimization problem belonging to the class of non-convex bi-objective mixed-integer non-linear programs (BOMINLP). In this manuscript, we propose and investigate a method to approximate the non-dominated set of the DfC problem with guarantees of global non-dominance. The BOMINLP is first scalarized using the method of $$\epsilon $$ ϵ -constraints. Feasible solutions with global optimality bounds are then computed for the resulting sequence of single-objective mixed-integer non-linear programs, using a tailored spatial branch-and-bound (sBB) method. In particular, we propose an equivalent reformulation of the non-linear resilience objective function to enable the computation of global optimality bounds. We show that our approach returns a set of potentially non-dominated solutions along with guarantees of their non-dominance in the form of a superset of the true non-dominated set of the BOMINLP. Finally, we evaluate the method on two case study networks and show that the tailored sBB method outperforms state-of-the-art global optimization solvers.


2014 ◽  
Vol 89 ◽  
pp. 1545-1552 ◽  
Author(s):  
V. Ruzza ◽  
E. Crestani ◽  
G. Darvini ◽  
P. Salandin

Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1929 ◽  
Author(s):  
Fabio Gatta ◽  
Alberto Geri ◽  
Stefano Lauria ◽  
Marco Maccioni

A Cross-Country Fault (CCF) is the simultaneous occurrence of a couple of Line-to-Ground Faults (LGFs), affecting different phases of same feeder or of two distinct ones, at different fault locations. CCFs are not uncommon in medium voltage (MV) public distribution networks operated with ungrounded or high-impedance neutral: despite the relatively small value of LGF current that is typical of such networks, CCF currents can be comparable to those that are found in Phase-To-Phase Faults, if the affected feeder(s) consists of cables. This occurs because the faulted cables’ sheaths/screens provide a continuous, relatively low-impedance metallic return path to the fault currents. An accurate evaluation is in order, since the resulting current magnitudes can overheat sheaths/screens, endangering cable joints and other plastic sheaths. Such evaluation, however, requires the modeling of the whole MV network in the phase domain, simulating cable screens and their connections to the primary and secondary substation earth electrodes by suitable computer programs, such as ATP (which is the acronym for alternative transient program) or EMTP (the acronym for electromagnetic transient program), with substantial input data being involved. This paper presents a simplified yet accurate circuit model of the faulted MV network, taking into account the CCF currents’ return path (cable sheaths/screens, ground conductors, and earthing resistances of secondary substations). The proposed CCF model can be implemented in a general-purpose simulation program, and it yields accurate fault currents estimates: for a 20 kV network case study, the comparison with accurate ATP simulations evidences mismatches mostly smaller than 2%, and never exceeding 5%.


2013 ◽  
Vol 07 (02) ◽  
pp. 1350005 ◽  
Author(s):  
GIAN PAOLO CIMELLARO ◽  
ALESSANDRO DE STEFANO ◽  
OMAR VILLA

The concept of disaster resilience has received considerable attention in recent years and it is increasingly used as an approach for understanding the dynamics of natural disaster systems. No models are available in literature to measure the performance of natural gas network, therefore, in this paper, a new performance index measuring functionality of gas distribution network have been proposed to evaluate the resilience index of the entire network. It can be used for any type of natural or manmade hazard which might lead to the disruption of the system. The gas distribution network of the municipalities of Introdacqua and Sulmona, two small towns in the center of Italy which were affected by 2009 earthquake have been used as case study. Together the pipeline network covers an area of 136 km2, with 3 M/R stations and 16 regulation groups. The software SynerGEE has been used to simulate different scenario events. The numerical results showed that, during emergency, to ensure an acceptable delivery service, it is crucial to guarantee the functionality of the medium pressure gas distribution network. Instead to improve resilience of the entire network the best retrofit strategy is to include emergency shutoff valves along the pipes.