scholarly journals Cooling performance of Ceiling Radiant Textile Air Conditioning System with Ceiling Cassette Unit of Packaged Air Conditioner

2019 ◽  
Vol 111 ◽  
pp. 01082
Author(s):  
Toshio Yamanaka ◽  
Mari Kuranaga ◽  
Tatsunori Maeda ◽  
Haruto Kitakaze

The authors developed a new radiant air conditioning system named ceiling radiant textile air conditioning system with ceiling cassette unit of packaged air conditioner (PAC). The nonflammable textile is stretched under the ceiling with ceiling cassette units of PAC with a distance of around 30 cm. The aim of this study is to investigate the cooling performance of this new radiant system, so the experiments with full scale model were conducted for three system. The first system is “textile only”, the second system is “textile with guide for air return grille” and the third system is “textile with guide and opening for air return grille”. Airflow rate through textile is measured by tracer gas method. In all cases, the vertical temperature distribution is almost uniform, and the cooling effect of “textile with guide and opening for air return grille” is the largest. As for the radiant effect, two systems of “only textile” and “textile with guide for air return grille” are superior to “textile with guide and opening for air return grille”. The airflow rate trough textile is doubled when using guide, and increased by five times if the opening was provided under the guide.

Author(s):  
David W. Gerlach

In electroosmotic dehumidification (EOD), a membrane composed of a desiccant material removes moisture from air to be conditioned. Then the water is pumped through pores in the membrane by the application of a voltage and rejected on the other side. This allows the sensible and latent loads in air conditioning to be handled separately and may lead to improvements in energy efficiency and comfort control. The performance of an air conditioning system using an electroosmotic dehumidification system in series with a conventional vapor compression cycle was modeled. The electroosmotic system handles the entire latent load and the vapor compression system handles the entire sensible cooling load. Performance of the system was compared to a conventional vapor compression air conditioner that handles both the latent and sensible loads with a single evaporator coil. Literature data for Nafion membranes was used in a simple electroosmotic drag model. Modeling indicates the feasibility of electroosmotic dehumidification for separating the control of latent and sensible load in air conditioning systems. The total COP of the system, neglecting fan power, can be 1–2 times higher (depending on airflow rate) than a system using an evaporator for latent and sensible load.


2021 ◽  
pp. 102585
Author(s):  
Kasni Sumeru ◽  
Mohamad Firdaus Sukri ◽  
Triaji Pangripto Pramudantoro ◽  
Eddy Erham ◽  
Rizki Muliawan

Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1927 ◽  
Author(s):  
Dandong Wang ◽  
Binbin Yu ◽  
Junye Shi ◽  
Jiangping Chen

CO2 (GWP = 1) is considered as a promising natural alternative refrigerant to HFC-134a in mobile air conditioning (MAC) applications. The objective of this study is to investigate the cooling performance characteristics of a CO2 MAC system. A prototype CO2 MAC system, consisting of a CO2 electrical compressor, CO2 parallel flow microchannel heat exchangers, and an electrical expansion valve, was developed and tested. Factor analysis experiments were conducted to reveal the effect of outdoor temperature on the cooling performance of this CO2 MAC system. Compared with a conventional R134a MAC system, the prototype CO2 MAC system achieved comparable cooling capacity, but had COP reductions of 26% and 10% at 27 °C and 45 °C outdoor conditions, respectively. In addition, based on refrigerant properties, theoretical cycle analysis was done to reveal the impact of evaporator, gas cooler and compressor, on the system cooling performance. It is concluded that the increase of overall compressor efficiency or the decrease of gas cooler approaching temperature could greatly improve the COP of this CO2 MAC system.


Author(s):  
Yuefen Gao ◽  
Xutao Zhang ◽  
Guohua Shi

Presently, the performance of the air-conditioner or the air-conditioning system is usually valued based on some performance indices. However, it is deficient to evaluate the performance of the air-conditioning system which uses the new energy or renewable energy only based on the indices mentioned above. According to the defects and based on the works of the solar application, a new index defined PVI is put forward to evaluate the performance of the solar air-conditioning system rationally, which is significant to the new energy or renewable energy application.


2014 ◽  
Vol 699 ◽  
pp. 828-833 ◽  
Author(s):  
Sumeru ◽  
Markus ◽  
Farid Nasir Ani ◽  
Henry Nasution

Air conditioning system consumes approximately 50% of the total energy consumption of buildings. Split-type air conditioner is the most widely used in residential and commercial buildings. As a result, enhancement on the performance of the air conditioners will yield a significant energy savings. The use of ejector as an expansion device on the split-type air conditioners is one method to increase the system performance. Exergy analysis on a split-type air conditioner uses an ejector as an expansion device at room and outdoor temperatures of 24 °C and 34 °C, respectively, yielded the percentage of exergy reduction up to 40.6%. Also, the exergy losses on in the compressor had the highest impact on the performance improvement of the split-type air conditioner.


2014 ◽  
Vol 501-504 ◽  
pp. 2244-2251 ◽  
Author(s):  
Xiang Lei Kong ◽  
Xin Li Zi ◽  
Long Yun ◽  
Xiao Song Zhang

Taking the radiant cooling combined with wall-attached-jet air-conditioning system as the subject in a laboratory of Jiangsu university, an experimental study was carried out on pre-dehumidifying period, stable operation period and system shutdown period, along with analysis. The objective is to analyze the pre-dehumidification of the system, indoor air temperature and humidification change, vertical temperature profile and condensation sensitivity. The results show that the hybrid air-conditioning can provide high thermal comfort and avoid condensation effectively, which shows the better performance compared to the system of radiant cooling combined with displacement ventilation to some extent.


2014 ◽  
Vol 672-674 ◽  
pp. 54-60 ◽  
Author(s):  
Ting Xiang Jin ◽  
Xiao Feng Xu

As coal, oil, natural gas and other non-renewable energy consumption and increasing energy demand, the utilization of solar energy as a new energy is greatly enhanced. In this work, a grid connected photovoltaic solar air conditioning system is designed, mainly comprised of solar panel, controller, inverter, room air conditioner and other parts. Air conditioning systems rely mainly on solar photovoltaic power; achieve the effect of energy conservation and environmental protection. The experimental result indicates that the system can achieve stable operation and the utilization of solar energy driving air conditioning system to save electricity. This air conditioning system is compared with the ordinary air conditioning system, SEER can increase 10.6 ~ 29.4%, HSPF can increase 6.25 ~ 18.5%.