scholarly journals Research on the maximum fire smoke temperature beneath tunnel ceilings using longitudinal ventilation

2018 ◽  
Vol 251 ◽  
pp. 02020
Author(s):  
Hui Yang ◽  
Bingyan Dong ◽  
Sijian Zhang ◽  
Dahui Sun ◽  
Kirill Lushin

The maximum fire smoke temperature beneath tunnel ceilings using longitudinal ventilation was studied by both small-scale experiments and numerical simulations for a small heat release rate (HRR) fire. And then, the accuracy of the numerical simulation is verified. A numerical simulation is subsequently employed to modify the Kurioka model for cases in large HRR. Then, the modified Kurioka model is verified by various on-site high HRR fire experimental results conducted by other authors.

2012 ◽  
Vol 518-523 ◽  
pp. 1269-1272 ◽  
Author(s):  
Liang Yi ◽  
Jie Chen

The aim of this work is to study the burning characteristics of coach fire. With application of computational fluid dynamics (FDS software package), coach fires caused by arson are simulated under different ventilation conditions. Variation of heat release rate (HRR) and distribution of temperature are analyzed. Peak heat release rate of coach fire caused by arson in passenger carriage can reach about 24 MW and maximum temperature in the carriage is over 1000 °C. Results of this study can be referred for fire protection and rescue design of coach.


Author(s):  
Dong Wang ◽  
Chao Zhang

Linear control models to control the Nitrogen Oxides (NOx) and soot emissions from a diesel engine were developed through numerical simulations. A modified KIVA-3V code was used to calculate the NOx and soot formations in a direct injection diesel engine under different operating conditions. The following relationships between the pollutant formations and the heat release rate were observed: 1) NOx formation amount is related to the peak value of the heat release rate and the timing of the premixed combustion; 2) soot formation amount is related to the peak heat release rate and the soot oxidation amount is related to the timing of the premixed combustion. Based on the above observations, linear control models for NOx and soot emissions were constructed. The NOx control model developed through the numerical simulations was implemented into the controller of an EGR valve on a small diesel engine. The experimental results showed that the NOx control model was effective in reducing NOx emissions under high RPM conditions.


Author(s):  
Alexander J. De Rosa ◽  
Janith Samarasinghe ◽  
Stephen J. Peluso ◽  
Bryan D. Quay ◽  
Domenic A. Santavicca

Fluctuations in the heat release rate that occur during unstable combustion in lean premixed gas turbine combustors can be attributed to velocity and equivalence ratio fluctuations. For a fully premixed flame, velocity fluctuations affect the heat release rate primarily by inducing changes in the flame area. In this paper, a technique to analyze changes in flame area using chemiluminescence-based flame images is presented. The technique decomposes the flame area into separate components which characterize the relative contributions of area fluctuations in the large scale structure and the small scale wrinkling of the flame. The fluctuation in the wrinkled area of the flame which forms the flame brush is seen to dominate its response in the majority of cases tested. Analysis of the flame area associated with the large scale structure of the flame resolves convective perturbations that move along the mean flame position. Results are presented that demonstrate the application of this technique to both single-nozzle and multi-nozzle flames.


2016 ◽  
Vol 13 (10) ◽  
pp. 7545-7547
Author(s):  
Xuefeng Han ◽  
Yao Deng ◽  
Xiaomei Wang ◽  
Juncheng Jiang

When evaluating the ASET (available safe egress time), the fire scenario and the heat release rate (HRR) of the fire need to be set firstly according to the function and the combustible materials of the building, then CFD (Computational Fluent Dynamics) software is used to perform simulations. The ASET is obtained at the time when the hazard index of smoke reaches the minimum value at a safety height, and this height could be defined as critical safety height. It is very important to select critical safety height and heat release rate for the accuracy of the simulation results. The variation of selection of the critical safety height in references is large and it is lacking of credible evidence. This paper discusses the critical safety height based on statistics, probability and ergonomicsvvso as to improve the accuracy, credibility and reliability of the numerical simulation.


2019 ◽  
Vol 37 (3) ◽  
pp. 213-235
Author(s):  
Yanqiu Chen ◽  
Dong Wang ◽  
Junmin Chen

Heat transfer and smoke flow filling progress in a super-high atrium is studied in this article. The influences of heat release rate and fire source height were considered. It was found that the fire smoke layer could not reach the top of the atrium when the heat release rate was very low and the fire source was located at the bottom of the atrium. The temperature of smoke layer interface and Δ Tmax were linearly positively related to Q2/3, while Δ Pmax was quadratically positively related to Q2/3. At the top of the atrium, the temperature rise and fire source height were consistent with the Boltzmann model. As the fire smoke rose with a velocity, a relatively low-pressure area was generated below. The pressure variation in this area was negatively index-related to the fire source height.


2019 ◽  
Vol 38 (1) ◽  
pp. 75-95
Author(s):  
Haiquan Bi ◽  
Yuanlong Zhou ◽  
Honglin Wang ◽  
Qilin Gou ◽  
Xiaoxia Liu

With the rapid development of high-speed railways, safety hazards presented by train fires cannot be ignored. An effective design for protection against fire in high-speed trains is essential to ensure passenger safety. In this study, the cone calorimeter and ignition temperature tester were used to carry out combustion experiments on materials constituting the main components of the train. The heat release rate, smoke yield, CO yield, and ignition temperature of combustible materials were tested. Based on the experimental data of material combustion, a numerical model of the high-speed train carriage fire was simulated. The accuracy of the numerical simulation was verified by drawing a comparison with the full-scale train fire experiment in existing literature. The numerical simulation results revealed that when the fire source is present at the corner of the carriage end door, the fire develops to the maximum possible extent in approximately 25 min, with a peak heat release rate of approximately 38.4 MW. Increase in the carriage fire heat release rate and breakage of windows occur almost simultaneously. Improvement of the fireproof performance of windows can inhibit and delay the carriage fire development. For the flashover of carriage fire, the spread speed of the flashover area in the longitudinal direction inside the carriage is approximately 1.9 m/s. The end door area furthest from the fire source in the carriage has strong flashover, while the flashover in other areas is weak.


2013 ◽  
Vol 831 ◽  
pp. 455-459
Author(s):  
Shu Hui Xu ◽  
Ling Fei Cui ◽  
Lei Ning ◽  
Zi Ye Wang

Critical velocity is a very important parameter in smoke control of tunnel fires and the variation of critical velocity against fire heat release rate is also one of the most important issues in tunnel fire researches. In this paper, a simplified physical model of a tunnel was established and the predictions of critical velocity for fire sizes in the 5-100MW range were carried out by FDS simulations. The FDS-predicted dimensionless critical velocities were compared with the values calculated by Wu and Bakar’s model. The result indicated that when the heat release rate was relatively small, Q≤30MW, the critical velocity increased with the increasing of heat release rate and varied as the one-third power of the heat release rate; when Q≥40MW, the growth rate of critical velocity became very small; after Q reach to 60MW, the critical velocity was almost unchanged with the increasing of heat release rate. In addition, the values of critical velocity calculated by Wu and Bakar’model which was derived from small-scale gas fire tests were underestimated. Therefore, the model suggested by Wu and Bakar is not suitable for critical velocity prediction in tunnel fires.


2019 ◽  
Vol 29 (7) ◽  
pp. 1017-1027
Author(s):  
Guanfeng Yan ◽  
Mingnian Wang ◽  
Li Yu ◽  
Yuan Tian

Nowadays, the critical velocity and back-layering length are the key parameters in longitudinal ventilation design. However, most studies research them at standard air pressure but ambient pressure decreases at high-altitude area and the reduced ambient pressure could affect the smoke movement characteristics in a tunnel fire. In order to investigate the effect of ambient pressure on the velocity and back-layering length in longitudinal ventilated tunnel, theoretical analysis was carried out first and a series of numerical simulation were conducted with varying heat release rate and ambient pressure. Results show that Li’s model is also reliable under various ambient pressures. The critical velocity under various ambient pressures would become larger with an increase in the heat release rate and would remain stable after the heat release rate reaches a certain value. At smaller heat release rate, the length of counterflow would be higher under reduced ambient pressure while it remains the same when the HRR is large. This could provide reference for tunnel ventilation design at high-altitude areas.


Sign in / Sign up

Export Citation Format

Share Document