Accuracy of MRI Diagnosis of Meniscal Tears of the Knee: A Meta-Analysis and Systematic Review

Author(s):  
Wei Wang ◽  
Zheng Li ◽  
Hui-Ming Peng ◽  
Yan-Yan Bian ◽  
Ye Li ◽  
...  

AbstractThis study aimed to evaluate the overall diagnostic value of magnetic resonance imaging (MRI) in patients with suspected meniscal tears. PubMed, Cochrane, Embase database updated to November 2017 were searched by the index words to identify qualified studies, including prospective cohort studies and cross-sectional studies. Literature was also identified by tracking using reference lists. Heterogeneity of the included studies was reviewed to select proper effects model for pooled weighted sensitivity, specificity, and diagnostic odds ratio (DOR). Summary receiver operating characteristic (SROC) analyses were performed for meniscal tears. A total of 17 studies were involved in this meta-analysis to explore the diagnostic accuracy of MRI for meniscal tears. The global sensitivity and specificity of MRI of meniscal tears were 92.0% (95% confidence interval [CI]: 88.0–95.0%) and 90.0% (95% CI: 85.0–95.0%) in medial meniscal tears, and 80.0% (95% CI: 66.0–89.0%) and 95.0% (95% CI: 91.0–97.0%) in lateral meniscal tears, respectively. Moreover, the global positive and negative likelihood ratio of MRI of meniscal tears were 10.33 (95% CI: 6.04–17.67) and 0.09 (95% CI: 0.05–0.14) in medial meniscal tears; 16.48 (95% CI: 8.81–30.83) and 0.21 (95% CI: 0.12–0.37) in lateral meniscal tears, respectively. The global DOR was 81.69 (95% CI: 37.94–175.91) in medial meniscal tears and 56.59 (95% CI: 22.51–142.28) in lateral meniscal tears. The results of area under the SROC indicated high accuracy in medial meniscal tears (area under the curve [AUC] = 0.97, 95% CI: 0.95–0.98) and lateral meniscal tears (AUC = 0.96, 95% CI: 0.94–0.97). This review presents a systematic review and meta-analysis to evaluate the diagnostic accuracy of MRI of meniscal tears. Moderate-to-strong evidence suggests that MRI appears to be associated with higher diagnostic accuracy for detecting medial and lateral meniscal tears.

2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2021 ◽  
Author(s):  
Bin Wu ◽  
◽  
Lixia Guo ◽  
Kaikai Zhen ◽  
Chao Sun

Review question / Objective: Background and aim: Increasing evidence has revealed the valuable diagnostic and prognostic applications of dysregulated microRNAs (miRNAs) in hepatoblastoma (HB), the most common hepatic malignancy during childhood. However, these results are inconsistent and remain to be elucidated. In the present study, we aimed to systematically compile up-to-date information regarding the clinical value of miRNAs in HB. Methods: Articles concerning the diagnostic and prognostic value of single miRNAs for HB were searched from databases. The sensitivity (SEN), specificity (SPE), positive and negative likelihood ratios (PLR and NLR), diagnostic odds ratio (DOR), area under the curve (AUC), and hazard ratios (HRs) were separately pooled to explore the diagnostic and prognostic performance of miRNA. Subgroup and meta-regression analyses were further carried out only in the event of heterogeneity. Results: In all, 20 studies, involving 264 HB patients and 206 healthy individuals, met the inclusion criteria in the six included literature articles. For the diagnostic analysis of miRNAs in HB, the pooled SEN and SPE were 0.76 (95% CI: 0.72–0.80) and 0.75 (95% CI: 0.70–0.80), respectively. Moreover, the pooled PLR was 2.79 (95% CI: 2.12–3.66), NLR was 0.34 (95% CI: 0.26–0.45), DOR was 10.24 (95% CI: 6.55–16.00), and AUC was 0.83, indicating that miRNAs had moderate diagnostic value in HB. For the prognostic analysis of miRNAs in HB, the abnormal expressions of miR-21, miR-34a, miR-34b, miR-34c, miR-492, miR-193, miR-222, and miR-224 in patients were confirmed to be associated with a worse prognosis. The pooled HR was 1.74 (95% CI: 1.20–2.29) for overall survival (OS) and 1.74 (95% CI: 1.31–2.18) for event-free survival (EFS), suggesting its potential as a prognostic indicator for HB. Conclusion: To the best of our knowledge, this is the first comprehensive systematic review and meta-analysis that examines the diagnostic and prognostic role of dysregulated miRNAs in HB patients. The combined meta-analysis results supported the previous individual finds that miRNAs might provide a new, noninvasive method for the diagnostic and prognostic analyses ofHB.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2020 ◽  
Author(s):  
Ke Wang ◽  
Shan Cong ◽  
Tiangang Ma ◽  
Xin Di ◽  
Chang Tian ◽  
...  

Abstract The aim of the study was to conduct a meta-analysis to evaluate the accuracy of neutrophil CD64, procalcitonin (PCT), and interleukin-6 (IL-6) for the diagnosis of sepsis. The sample articles were searched in various databases to collect published studies on the diagnosis of sepsis by neutrophil CD64, PCT, and IL-6. By using the Stata SE 15.0 software, forest plots and the area under the summary receiver operating characteristic curves were drawn. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC) were calculated. 54 articles were included in the study. The number of studies that evaluated the diagnostic value of neutrophil CD64, PCT, and interleukin-6 were 20, 39, and 15, respectively. The pooled sensitivity, specificity, and AUC of neutrophil CD64 for the diagnosis of sepsis were 0.88 [95% confidence interval (CI), 0.81–0.92], 0.88 (95% CI, 0.83–0.91), and 0.94 (95% CI, 0.91–0.96), respectively. The pooled sensitivity, specificity, and AUC of PCT for the diagnosis of sepsis were 0.82 (95% CI, 0.78–0.85), 0.78 (95% CI, 0.74–0.82), and 0.87 (95% CI, 0.83–0.89), respectively. Subgroup analysis showed that the AUC for PCT diagnosis of intensive care unit (ICU) sepsis was 0.86 (95% CI, 0.83–0.89) and the AUC for PCT diagnosis of non-ICU sepsis was 0.82 (95% CI, 0.78–0.85). The pooled sensitivity, specificity, and AUC of IL-6 for the diagnosis of sepsis were 0.72 (95% CI, 0.65–0.78), 0.70 (95% CI, 0.62–0.76), and 0.77 (95% CI, 0.73–0.80), respectively. Of the three biomarkers studied, neutrophil CD64 showed the highest diagnostic value for sepsis, followed by PCT, and IL-6. On the other hand, PCT showed a better diagnostic value for the diagnosis of sepsis in patients with severe conditions compared with that in patients with non-severe conditions.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Yubao Cui ◽  
Shanchao Hong ◽  
Xuming Zhu

Background. Ovarian cancer is the 5th leading cause of death of women due to cancer in the United States. Although carbohydrate antigen 125 has a moderate diagnostic utility, the phenomenon of false-positive exists. As novel effective biomarkers, some single microRNAs (miRNAs) have diagnostic values for ovarian cancer, but the results lack consistency. In order to precisely and comprehensively assess the diagnostic value of single miRNAs for ovarian cancer, a meta-analysis is performed. Methods. Articles concerning the diagnostic value of single miRNAs for ovarian cancer were searched from databases. The pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) with the corresponding 95% confidence interval (CI) were calculated. Area under curve (AUC) of the summary receiver-operating characteristic (SROC) curve was also calculated. Results. In total, 22 studies including 8 kinds of single miRNAs were enrolled in this paper (6 studies for miR-200c, 3 studies for miR-200a and miR-200b, and 2 studies for miR-205, miR-145, miR-141, miR-429, and miR-125b). For miR-200c, the pooled SEN and SPE were, respectively, 0.768 (95% CI: 0.722-0.811) and 0.680 (95% CI: 0.624-0.732); the pooled PLR and NLR were, respectively, 2.897 (95% CI: 1.787-4.698) and 0.340 (95% CI: 0.276-0.417); the pooled DOR was 8.917 (95% CI: 4.521-17.587); and AUC of SROC curve was 0.815. For miR-200a, the pooled SEN and SPE were, respectively, 0.759 (95% CI: 0.670-0.833) and 0.717 (95% CI: 0.627-0.795); the pooled PLR and NLR were, respectively, 3.129 (95% CI: 0.997-9.816) and 0.301 (95% CI: 0.207-0.437); the pooled DOR was 11.323 (95% CI: 3.493-36.711); and AUC of SROC curve was 0.857. For miR-200b, the pooled SEN and SPE were, respectively, 0.853 (95% CI: 0.776-0.912) and 0.775 (95% CI: 0.690-0.846); the pooled PLR and NLR were, respectively, 4.327 (95% CI: 0.683-27.415) and 0.225 (95% CI: 0.081-0.625); the pooled DOR was 19.678 (95% CI: 2.812-137.72); and AUC of SROC curve was 0.90. For miR-205, miR-145, miR-141, miR-429, and miR-125b, each diagnostic value should be interpreted cautiously because only two studies were included. Conclusions. miR-200c, miR-200a, and miR-200b can be useful diagnostic biomarkers for ovarian cancer. More related studies are needed for miR-205, miR-145, miR-141, miR-429, and miR-125b.


2021 ◽  
Vol 8 ◽  
Author(s):  
Jiangbi Li ◽  
Xiaoping Xie ◽  
Weibing Liu ◽  
Feng Gu ◽  
Ke Zhang ◽  
...  

Background: Abnormal expression levels of microRNAs (miRNAs) were observed in ankylosing spondylitis (AS) in recent articles, suggesting that miRNAs may be used as biomarkers for AS diagnoses. In this paper, we conducted a meta-analysis to identify the overall diagnostic accuracy of miRNA biomarkers in AS patients.Methods: An extensive search was undertaken in PubMed, Embase, Cochrane databases, and Wan Fang database up to 30 December 2020 using the following key words: (“microRNAs” or “microRNA” or “miRNA” or “miR” or “RNA, Micro” or “Primary MicroRNA”) and (“Spondylitis Ankylosing” or “Spondyloarthritis Ankylopoietica” or “Ankylosing Spondylarthritis” or “Ankylosing Spondylarthritides” or “Spondylarthritides Ankylosing” or “Ankylosing Spondylitis”) and (“blood” or “serum” or “plasma”). Statistical evaluation of dysregulated miRNAs using the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC).Results: Twenty-nine articles reporting on the miRNAs of AS were included. A total of 42 miRNAs were observed to be up-regulated and 45 miRNAs were down-regulated in the AS cases compared with the controls. Besides, 29 studies from nine articles were included in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0. 76 (95% CI, 0.70–0.81), 0.80 (95% CI, 0.74–0.85), 3.75 (95% CI, 2.82–5.01), 0.30 (95% CI, 0.24–0.39), 12.32 (95% CI, 7.65–19.83), 0.85 (95% CI, 0.81–0.88), respectively, suggesting a good diagnostic accuracy of miRNAs for AS.Conclusions: Circulating miRNAs are deregulated in AS patients. miRNAs may be used as a relatively non-invasive biomarkers for the detection of AS.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Chao Sun ◽  
Bin Wu ◽  
Jiang Pan ◽  
Lulu Chen ◽  
Wenxian Zhi ◽  
...  

Aim. Increasing evidence indicates that hepatic subcapsular flow (HSF) can serve as a noninvasive ultrasonographic marker for the early diagnosis of biliary atresia (BA). However, results regarding its diagnostic accuracy are inconsistent and inconclusive. We conducted this meta-analysis with an aim to systematically evaluate the diagnostic value of HSF in predicting BA. Methods. A comprehensive literature search of four databases was conducted to identify the eligible studies. All analyses were performed using STATA 12.0. Results. Nine studies from eight articles containing 368 patients and 469 controls were included in our meta-analysis. Briefly, the values for pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were 0.95 (95% CI 0.88-0.98), 0.92 (95% CI 0.85-0.96), 11.6 (95% CI 6.3-21.5), 0.06 (95% CI 0.02-0.14), 201 (95% CI 59-689), and 0.98 (95% CI 0.96-0.99), respectively. Additionally, metaregression along with subgroup analysis based on various covariates revealed the potential sources of heterogeneity and the detailed diagnostic value in each subgroup. Conclusion. Our meta-analysis showed that HSF assay could provide high accuracy in predicting BA patients and non-BA individuals. However, further studies with better design and larger sample size are required to support the results of the present study.


2018 ◽  
Vol 20 (2) ◽  
pp. 164 ◽  
Author(s):  
Fajin Dong ◽  
Lei Zhang ◽  
Shuxia Wang ◽  
Duo Dong ◽  
Jinfeng Xu ◽  
...  

Aim: To evaluate the diagnostic accuracy of meniscal tears using B-mode ultrasound and high-frequency linear probe by conducting a systematic review and pooled meta-analysis. Material and methods: The Cochrane library, Embase, and Pubmed were searched for relevant studies up to 29 July 2017. The arthroscopy was used as the reference standard. The results were estimated by pooled sensitivity, specificity, diagnostic odds ratio, likelihood ratio, and the area under the summary receiver operating characteristic (SROC). Results: Seven prospective studies met the selection criteria, comprising 321meniscal tears from 472 patients. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the SROC curve were 88.80% (95%CI: 82.83-92.87), 84.66% (95%CI: 75.89-90.64), 5.79(95%CI: 3.66-9.15), 0.13 (95%CI: 0.09-0.20), and 43.74 (95%CI: 24.01-79.68), respectively. The area under the SROC curve was 93% (95%CI: 91-95). Conclusions: This meta-analysis indicates that 2-dimensional ultrasound is useful, and could be routinely used for estimating meniscal injuries in the human knee joint


2019 ◽  
Author(s):  
Zhenhua Zhang ◽  
Saber Imani ◽  
Marzieh Dehghan Shasaltaneh ◽  
Hossein Hosseinifard ◽  
Zou Linglin ◽  
...  

Abstract Background Vasculogenic mimicry (VM), a brand-new tumor microvascular model of non-endothelial cells, is proposed as an important therapeutic target in malignant melanoma (MM). We performed a systematic review to evaluate the diagnostic and prognostics accuracy of VM for overall survival of MM patients. Methods The quality of the included studies was assessed by QUADAS-2 tool. Diagnostic capacity of VM variables were pooled by the Meta-Disc software in term of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the summary receiver operating characteristic (SROC). Results A retrospective observational study was conducted based on ‎ten studies including 978 clinically melanoma patients with proportion (P). VM+ melanoma cells are associated with poor prognosis in 38% of MM group (P = 0.35, 95% confidence intervals (CI): 0.27-0.42, P-value < 0.001). The pooled sensitivity and specificity were 0.82 (95% CI: 0.79-0.84) and 0.69 (95% CI: 0.66-0.71), respectively. Furthermore, the pooled PLR, NLR, and DOR were 2.56 (95% CI: 1.94-3.93), 0.17 (95% CI: 0.07-0.42), and 17.75 (95% CI: 5.30-59.44), respectively. Also, the AUC of SROC was 0.63, indicating the highly conserving of VM as a biomarker‎. Importantly, subgroup results suggested that VM+ tumor was significantly accurate prognostics biomarkers when diagnosed by CD31-/PAS+ staining methods in Asian MM samples (P-value > 0.001). Conclusions Our finding supports the VM+ tumor as a promising prognostic biomarker and effective adjuvant therapeutic strategy in prognostics of Asian MM patients.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0243797
Author(s):  
Lei Fan ◽  
Xue-Jian Wu

The risk of amputation is a sequelae of diabetic foot ulceration, which are significantly increased in diabetic patients and caused huge morbidly and mortality. However, whether the risk amputation in diabetic patients are differing in male and female remains inconclusive. We therefore conducted a systematic review and meta-analysis to assess the sex difference for the risk of amputation in diabetic patients. We systematically searched PubMed, EmBase, and the Cochrane library to identify eligible study from their inception up to November 2020. The diagnostic value of male patients on subsequent amputation risk were assessed by using sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), diagnostic odds ratio (DOR), and area under the receiver operating characteristic curve (AUC). Twenty-two studies recruited a total of 33,686,171 diabetic patients were selected for quantitative analysis. The risk of amputation in male diabetic patients was greater than female diabetic patients (DOR: 1.38; 95%CI: 1.13–1.70; P<0.001). The sensitivity and specificity for male diabetic patients on the risk of amputation were 0.72 (95%CI: 0.72–0.73), and 0.51 (95%CI: 0.51–0.51), respectively. Moreover, the PLR and NLR of male diabetic patients for predicting amputation were 1.13 (95%CI: 1.05–1.22), and 0.82 (0.72–0.94), respectively. Furthermore, the AUC for male diabetic patients on amputation risk was 0.56 (95%CI: 0.48–0.63). This study found male diabetic patients was associated with an increased risk of amputation than female diabetic patients, and the predictive value of sex difference on amputation risk in diabetic patients was mild.


Sign in / Sign up

Export Citation Format

Share Document