scholarly journals Diagnostic value of neutrophil CD64, procalcitonin, and interleukin-6 in sepsis: A meta-analysis

2020 ◽  
Author(s):  
Ke Wang ◽  
Shan Cong ◽  
Tiangang Ma ◽  
Xin Di ◽  
Chang Tian ◽  
...  

Abstract The aim of the study was to conduct a meta-analysis to evaluate the accuracy of neutrophil CD64, procalcitonin (PCT), and interleukin-6 (IL-6) for the diagnosis of sepsis. The sample articles were searched in various databases to collect published studies on the diagnosis of sepsis by neutrophil CD64, PCT, and IL-6. By using the Stata SE 15.0 software, forest plots and the area under the summary receiver operating characteristic curves were drawn. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC) were calculated. 54 articles were included in the study. The number of studies that evaluated the diagnostic value of neutrophil CD64, PCT, and interleukin-6 were 20, 39, and 15, respectively. The pooled sensitivity, specificity, and AUC of neutrophil CD64 for the diagnosis of sepsis were 0.88 [95% confidence interval (CI), 0.81–0.92], 0.88 (95% CI, 0.83–0.91), and 0.94 (95% CI, 0.91–0.96), respectively. The pooled sensitivity, specificity, and AUC of PCT for the diagnosis of sepsis were 0.82 (95% CI, 0.78–0.85), 0.78 (95% CI, 0.74–0.82), and 0.87 (95% CI, 0.83–0.89), respectively. Subgroup analysis showed that the AUC for PCT diagnosis of intensive care unit (ICU) sepsis was 0.86 (95% CI, 0.83–0.89) and the AUC for PCT diagnosis of non-ICU sepsis was 0.82 (95% CI, 0.78–0.85). The pooled sensitivity, specificity, and AUC of IL-6 for the diagnosis of sepsis were 0.72 (95% CI, 0.65–0.78), 0.70 (95% CI, 0.62–0.76), and 0.77 (95% CI, 0.73–0.80), respectively. Of the three biomarkers studied, neutrophil CD64 showed the highest diagnostic value for sepsis, followed by PCT, and IL-6. On the other hand, PCT showed a better diagnostic value for the diagnosis of sepsis in patients with severe conditions compared with that in patients with non-severe conditions.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Shan Cong ◽  
Tiangang Ma ◽  
Xin Di ◽  
Chang Tian ◽  
Min Zhao ◽  
...  

Abstract Background The aim of the study was to conduct a meta-analysis to evaluate the accuracy of neutrophil CD64, procalcitonin (PCT), and interleukin-6 (IL-6) as markers for the diagnosis of sepsis in adult patients. Methods Various databases were searched to collect published studies on the diagnosis of sepsis in adult patients using neutrophil CD64, PCT, and IL-6 levels. Utilizing the Stata SE 15.0 software, forest plots and the area under the summary receiver operating characteristic curves were drawn. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC) were calculated. Results Fifty-four articles were included in the study. The pooled sensitivity, specificity, and AUC of neutrophil CD64 for the diagnosis of sepsis were 0.88 (95% confidence interval [CI], 0.81–0.92), 0.88 (95% CI, 0.83–0.91), and 0.94 (95% CI, 0.91–0.96), respectively. The pooled sensitivity, specificity, and AUC of PCT for the diagnosis of sepsis were 0.82 (95% CI, 0.78–0.85), 0.78 (95% CI, 0.74–0.82), and 0.87 (95% CI, 0.83–0.89), respectively. Subgroup analysis showed that the AUC for PCT diagnosis of intensive care unit (ICU) sepsis was 0.86 (95% CI, 0.83–0.89) and the AUC for PCT diagnosis of non-ICU sepsis was 0.82 (95% CI, 0.78–0.85). The pooled sensitivity, specificity, and AUC of IL-6 for the diagnosis of sepsis were 0.72 (95% CI, 0.65–0.78), 0.70 (95% CI, 0.62–0.76), and 0.77 (95% CI, 0.73–0.80), respectively. Conclusions Of the three biomarkers studied, neutrophil CD64 showed the highest diagnostic value for sepsis, followed by PCT, and IL-6. On the other hand, PCT showed a better diagnostic potential for the diagnosis of sepsis in patients with severe conditions compared with that in patients with non-severe conditions.


2020 ◽  
Vol 7 ◽  
Author(s):  
Ying Luo ◽  
Ying Xue ◽  
Liyan Mao ◽  
Qun Lin ◽  
Guoxing Tang ◽  
...  

Background: Tuberculous peritonitis (TP) is a common form of abdominal tuberculosis (TB). Diagnosing TP remains challenging in clinical practice. The aim of the present meta-analysis was to evaluate the diagnostic accuracy of peripheral blood (PB) T-SPOT and peritoneal fluid (PF) T-SPOT for diagnosing TP.Methods: PubMed, EmBase, Cochrane, Scopus, Google scholar, China national knowledge internet, and Wan-Fang databases were searched for relevant articles from August 1, 2005 to July 5, 2020. Statistical analysis was performed using Stata, Revman, and Meta-Disc software. Diagnostic parameters including pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were determined. Summary receiver operating characteristic curve was used to determine the area under the curve (AUC).Results: Twelve studies were eligible and included in the meta-analysis. The analysis showed that the pooled sensitivity and specificity of PB T-SPOT in diagnosing TP were 0.91 (95% CI, 0.88–0.94) and 0.78 (95% CI, 0.73–0.81), respectively, while the pooled PLR, NLR, and DOR were 4.05 (95% CI, 2.73–6.01), 0.13 (95% CI, 0.07–0.23), and 37.8 (95% CI, 15.04–94.98), respectively. On the other hand, the summary estimates of sensitivity, specificity, PLR, NLR, and DOR of PF T-SPOT for TP diagnosis were 0.90 (95% CI, 0.85–0.94), 0.78 (95% CI, 0.72–0.83), 6.35 (95% CI, 2.67–15.07), 0.14 (95% CI, 0.09–0.21), and 58.22 (95% CI, 28.76–117.83), respectively. Furthermore, the AUC of PB T-SPOT and PF T-SPOT for TP diagnosis were 0.91 and 0.94, respectively.Conclusions: Our results indicate that both PB T-SPOT and PF T-SPOT can be served as sensitive approaches for the diagnosis of TP. However, the unsatisfactory specificities of these two methods limit their application as rule-in tests for TP diagnosis. Furthermore, the standardization of the operating procedure of PF T-SPOT is further needed.


2021 ◽  
Author(s):  
Jiangfeng Wu ◽  
Yue Sun ◽  
Yunlai Wang ◽  
Lijing Ge ◽  
Yun Jin ◽  
...  

Aims: In the present study, a meta-analysis was performed to evaluate the diagnostic value of endobronchial ultrasound (EBUS) elastography for differentiating benign and malignant hilar and mediastinal lymph nodes (LNs). Material and methods: A comprehensive literature search was carried out through PubMed, Embase, and Cochrane Library. Two authors screened the papers and extracted the data independently and any discrepancies were resolved by discussion. The methodolog-ical quality of each included study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve were calculated to evaluate the value of EBUS elastography for hilar and mediastinal LNs. Results: Seventeen studies with the number of 2307 LNs were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio for the diagnosis of hilar and mediastinal LNs by EBUS elastography were 0.90 (95% confidence interval [CI], 0.84-0.94), 0.78 (95% CI, 0.74-0.81), 4.1 (95% CI, 3.4-4.9), 0.12 (95% CI, 0.07-0.21) and 33 (95% CI, 17-64), respectively. Furthermore, area under the curve was calculated to be 0.86 (95% CI, 0.82-0.88). Conclusion: EBUS elastography is a valuable technology in the differentiation of benign and malignant hilar and mediastinal LNs and could provide supplementary diagnostic information during endobronchial ultrasound-guided transbronchial needle aspiration. The combination of EBUS elastography and B-mode EBUS could improve the diagnostic accuracy for hilar and mediastinal LNs.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Chao Sun ◽  
Bin Wu ◽  
Jiang Pan ◽  
Lulu Chen ◽  
Wenxian Zhi ◽  
...  

Aim. Increasing evidence indicates that hepatic subcapsular flow (HSF) can serve as a noninvasive ultrasonographic marker for the early diagnosis of biliary atresia (BA). However, results regarding its diagnostic accuracy are inconsistent and inconclusive. We conducted this meta-analysis with an aim to systematically evaluate the diagnostic value of HSF in predicting BA. Methods. A comprehensive literature search of four databases was conducted to identify the eligible studies. All analyses were performed using STATA 12.0. Results. Nine studies from eight articles containing 368 patients and 469 controls were included in our meta-analysis. Briefly, the values for pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were 0.95 (95% CI 0.88-0.98), 0.92 (95% CI 0.85-0.96), 11.6 (95% CI 6.3-21.5), 0.06 (95% CI 0.02-0.14), 201 (95% CI 59-689), and 0.98 (95% CI 0.96-0.99), respectively. Additionally, metaregression along with subgroup analysis based on various covariates revealed the potential sources of heterogeneity and the detailed diagnostic value in each subgroup. Conclusion. Our meta-analysis showed that HSF assay could provide high accuracy in predicting BA patients and non-BA individuals. However, further studies with better design and larger sample size are required to support the results of the present study.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


Cancers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 5253
Author(s):  
Md. Mohaimenul Islam ◽  
Tahmina Nasrin Poly ◽  
Bruno Andreas Walther ◽  
Ming-Chin Lin ◽  
Yu-Chuan (Jack) Li

Gastric cancer (GC) is one of the most newly diagnosed cancers and the fifth leading cause of death globally. Identification of early gastric cancer (EGC) can ensure quick treatment and reduce significant mortality. Therefore, we aimed to conduct a systematic review with a meta-analysis of current literature to evaluate the performance of the CNN model in detecting EGC. We conducted a systematic search in the online databases (e.g., PubMed, Embase, and Web of Science) for all relevant original studies on the subject of CNN in EGC published between January 1, 2010, and March 26, 2021. The Quality Assessment of Diagnostic Accuracy Studies-2 was used to assess the risk of bias. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Moreover, a summary receiver operating characteristic curve (SROC) was plotted. Of the 171 studies retrieved, 15 studies met inclusion criteria. The application of the CNN model in the diagnosis of EGC achieved a SROC of 0.95, with corresponding sensitivity of 0.89 (0.88–0.89), and specificity of 0.89 (0.89–0.90). Pooled sensitivity and specificity for experts endoscopists were 0.77 (0.76–0.78), and 0.92 (0.91–0.93), respectively. However, the overall SROC for the CNN model and expert endoscopists was 0.95 and 0.90. The findings of this comprehensive study show that CNN model exhibited comparable performance to endoscopists in the diagnosis of EGC using digital endoscopy images. Given its scalability, the CNN model could enhance the performance of endoscopists to correctly stratify EGC patients and reduce work load.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xingyang Zhu ◽  
Haitao Zhang ◽  
Xiaobo Sun ◽  
Yijin Li ◽  
Jiahao Li ◽  
...  

Abstract Background Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. Methods We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. Results Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. Conclusion The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Yubao Cui ◽  
Shanchao Hong ◽  
Xuming Zhu

Background. Ovarian cancer is the 5th leading cause of death of women due to cancer in the United States. Although carbohydrate antigen 125 has a moderate diagnostic utility, the phenomenon of false-positive exists. As novel effective biomarkers, some single microRNAs (miRNAs) have diagnostic values for ovarian cancer, but the results lack consistency. In order to precisely and comprehensively assess the diagnostic value of single miRNAs for ovarian cancer, a meta-analysis is performed. Methods. Articles concerning the diagnostic value of single miRNAs for ovarian cancer were searched from databases. The pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) with the corresponding 95% confidence interval (CI) were calculated. Area under curve (AUC) of the summary receiver-operating characteristic (SROC) curve was also calculated. Results. In total, 22 studies including 8 kinds of single miRNAs were enrolled in this paper (6 studies for miR-200c, 3 studies for miR-200a and miR-200b, and 2 studies for miR-205, miR-145, miR-141, miR-429, and miR-125b). For miR-200c, the pooled SEN and SPE were, respectively, 0.768 (95% CI: 0.722-0.811) and 0.680 (95% CI: 0.624-0.732); the pooled PLR and NLR were, respectively, 2.897 (95% CI: 1.787-4.698) and 0.340 (95% CI: 0.276-0.417); the pooled DOR was 8.917 (95% CI: 4.521-17.587); and AUC of SROC curve was 0.815. For miR-200a, the pooled SEN and SPE were, respectively, 0.759 (95% CI: 0.670-0.833) and 0.717 (95% CI: 0.627-0.795); the pooled PLR and NLR were, respectively, 3.129 (95% CI: 0.997-9.816) and 0.301 (95% CI: 0.207-0.437); the pooled DOR was 11.323 (95% CI: 3.493-36.711); and AUC of SROC curve was 0.857. For miR-200b, the pooled SEN and SPE were, respectively, 0.853 (95% CI: 0.776-0.912) and 0.775 (95% CI: 0.690-0.846); the pooled PLR and NLR were, respectively, 4.327 (95% CI: 0.683-27.415) and 0.225 (95% CI: 0.081-0.625); the pooled DOR was 19.678 (95% CI: 2.812-137.72); and AUC of SROC curve was 0.90. For miR-205, miR-145, miR-141, miR-429, and miR-125b, each diagnostic value should be interpreted cautiously because only two studies were included. Conclusions. miR-200c, miR-200a, and miR-200b can be useful diagnostic biomarkers for ovarian cancer. More related studies are needed for miR-205, miR-145, miR-141, miR-429, and miR-125b.


2021 ◽  
Vol 8 ◽  
Author(s):  
Jiangbi Li ◽  
Xiaoping Xie ◽  
Weibing Liu ◽  
Feng Gu ◽  
Ke Zhang ◽  
...  

Background: Abnormal expression levels of microRNAs (miRNAs) were observed in ankylosing spondylitis (AS) in recent articles, suggesting that miRNAs may be used as biomarkers for AS diagnoses. In this paper, we conducted a meta-analysis to identify the overall diagnostic accuracy of miRNA biomarkers in AS patients.Methods: An extensive search was undertaken in PubMed, Embase, Cochrane databases, and Wan Fang database up to 30 December 2020 using the following key words: (“microRNAs” or “microRNA” or “miRNA” or “miR” or “RNA, Micro” or “Primary MicroRNA”) and (“Spondylitis Ankylosing” or “Spondyloarthritis Ankylopoietica” or “Ankylosing Spondylarthritis” or “Ankylosing Spondylarthritides” or “Spondylarthritides Ankylosing” or “Ankylosing Spondylitis”) and (“blood” or “serum” or “plasma”). Statistical evaluation of dysregulated miRNAs using the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC).Results: Twenty-nine articles reporting on the miRNAs of AS were included. A total of 42 miRNAs were observed to be up-regulated and 45 miRNAs were down-regulated in the AS cases compared with the controls. Besides, 29 studies from nine articles were included in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0. 76 (95% CI, 0.70–0.81), 0.80 (95% CI, 0.74–0.85), 3.75 (95% CI, 2.82–5.01), 0.30 (95% CI, 0.24–0.39), 12.32 (95% CI, 7.65–19.83), 0.85 (95% CI, 0.81–0.88), respectively, suggesting a good diagnostic accuracy of miRNAs for AS.Conclusions: Circulating miRNAs are deregulated in AS patients. miRNAs may be used as a relatively non-invasive biomarkers for the detection of AS.


2020 ◽  
Vol 22 (2) ◽  
pp. 211
Author(s):  
Jun Li ◽  
Tian Sang ◽  
Wen-Hui Yu ◽  
Meng Jiang ◽  
Shu-Yan Hunag ◽  
...  

Aim: To evaluate the value of S-Detect (a computer aided diagnosis system using deep learning) in breast ultrasound (US) for discriminating benign and malignant breast masses.Material and methods: A literature search was performed and relevant studies using S-Detect for the differential diagnosis of breast masses were selected. The quality of included studies was assessed using a Quality Assessment of Diagnostic Accuracy Studies (QUADAS) questionnaire. Two review authors independently searched the articles and assessed the eligibility of the reports.Results: A total of ten studies were included in the meta-analysis. The pooled estimates of sensitivity and specificity were 0.82 (95%CI: 0.77-0.87) and 0.86 (95%CI: 0.76-0.92), respectively. In addition, the diagnostic odds ratios, positive likelihood ratio and negative likelihood ratio were 28 (95%CI: 16- 49), 5.7 (95%CI: 3.4-9.5), and 0.21 (95%CI: 0.16-0.27), respectively. Area under the curve was 0.89 (95%CI: 0.86-0.92). No significant publication bias was observed.Conclusions: S-Detect exhibited a favourable diagnostic value in assisting physicians discriminating benign and malignant breast masses and it can be considered as a useful complement for conventional US.


Sign in / Sign up

Export Citation Format

Share Document