Wavelet-based multifractal analysis of large scale wind turbine main bearing

2013 ◽  
Vol 5 (1) ◽  
pp. 013102 ◽  
Author(s):  
Changzheng Chen ◽  
Xianming Sun ◽  
Quan Gu ◽  
Bo Zhou ◽  
Yanling Gu
2013 ◽  
Vol 644 ◽  
pp. 337-340
Author(s):  
Quan Gu ◽  
Chang Zheng Chen ◽  
Xiang Jun Kong ◽  
Xian Ming Sun ◽  
Bo Zhou ◽  
...  

Because the vibration signals of faulty wind turbine are non-linear and non-stationary, to obtain the obvious fault features become difficult. In this study, the incipient fault of the main bearing used in large scale wind turbine is studied by using a multifractal method based on the Wavelet Modulus Maxima (WTMM) method. The real vibration signals from the main bearings are analyzed using the multifractal spectrum. The spectrum of the vibration signals is quantified by spectral characteristics including its range and the Hölder exponent corresponding to the maximum dimension. The results show that the range of Hölder exponent of the main bearing which worked normally is much narrower. While the ranges of the vibration signals of the main bearing with incipient fault are wider. We also found that the fault features are different at various wind turbine rotational frequencies. Those demonstrate that the incipient fault features of main bearing of large scale wind turbine can be extract effectively using the multifractal spectrum obtained from WTMM method.


Author(s):  
Xu Pei-Zhen ◽  
Lu Yong-Geng ◽  
Cao Xi-Min

Background: Over the past few years, the subsynchronous oscillation (SSO) caused by the grid-connected wind farm had a bad influence on the stable operation of the system and has now become a bottleneck factor restricting the efficient utilization of wind power. How to mitigate and suppress the phenomenon of SSO of wind farms has become the focus of power system research. Methods: This paper first analyzes the SSO of different types of wind turbines, including squirrelcage induction generator based wind turbine (SCIG-WT), permanent magnet synchronous generator- based wind turbine (PMSG-WT), and doubly-fed induction generator based wind turbine (DFIG-WT). Then, the mechanisms of different types of SSO are proposed with the aim to better understand SSO in large-scale wind integrated power systems, and the main analytical methods suitable for studying the SSO of wind farms are summarized. Results: On the basis of results, using additional damping control suppression methods to solve SSO caused by the flexible power transmission devices and the wind turbine converter is recommended. Conclusion: The current development direction of the SSO of large-scale wind farm grid-connected systems is summarized and the current challenges and recommendations for future research and development are discussed.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2287
Author(s):  
Kaina Qin ◽  
Shanshan Wang ◽  
Zhongjian Kang

With the rapid increase in the proportion of the installed wind power capacity in the total grid capacity, the state has put forward higher and higher requirements for wind power integration into the grid, among which the most difficult requirement is the zero-voltage ride through (ZVRT) capability of the wind turbine. When the voltage drops deeply, a series of transient processes, such as serious overvoltage, overcurrent, or speed rise, will occur in the motor, which will seriously endanger the safe operation of the wind turbine itself and its control system, and cause large-scale off-grid accident of wind generator. Therefore, it is of great significance to improve the uninterrupted operation ability of the wind turbine. Doubly fed induction generator (DFIG) can achieve the best wind energy tracking control in a wide range of wind speed and has the advantage of flexible power regulation. It is widely used at present, but it is sensitive to the grid voltage. In the current study, the DFIG is taken as the research object. The transient process of the DFIG during a fault is analyzed in detail. The mechanism of the rotor overcurrent and DC bus overvoltage of the DFIG during fault is studied. Additionally, the simulation model is built in DIgSILENT. The active crowbar hardware protection circuit is put into the rotor side of the wind turbine, and the extended state observer and terminal sliding mode control are added to the grid side converter control. Through the cooperative control technology, the rotor overcurrent and DC bus overvoltage can be suppressed to realize the zero-voltage ride-through of the doubly fed wind turbine, and ensure the safe and stable operation of the wind farm. Finally, the simulation results are presented to verify the theoretical analysis and the proposed control strategy.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3598
Author(s):  
Sara Russo ◽  
Pasquale Contestabile ◽  
Andrea Bardazzi ◽  
Elisa Leone ◽  
Gregorio Iglesias ◽  
...  

New large-scale laboratory data are presented on a physical model of a spar buoy wind turbine with angular motion of control surfaces implemented (pitch control). The peculiarity of this type of rotating blade represents an essential aspect when studying floating offshore wind structures. Experiments were designed specifically to compare different operational environmental conditions in terms of wave steepness and wind speed. Results discussed here were derived from an analysis of only a part of the whole dataset. Consistent with recent small-scale experiments, data clearly show that the waves contributed to most of the model motions and mooring loads. A significant nonlinear behavior for sway, roll and yaw has been detected, whereas an increase in the wave period makes the wind speed less influential for surge, heave and pitch. In general, as the steepness increases, the oscillations decrease. However, higher wind speed does not mean greater platform motions. Data also indicate a significant role of the blade rotation in the turbine thrust, nacelle dynamic forces and power in six degrees of freedom. Certain pairs of wind speed-wave steepness are particularly unfavorable, since the first harmonic of the rotor (coupled to the first wave harmonic) causes the thrust force to be larger than that in more energetic sea states. The experiments suggest that the inclusion of pitch-controlled, variable-speed blades in physical (and numerical) tests on such types of structures is crucial, highlighting the importance of pitch motion as an important design factor.


2014 ◽  
Vol 670-671 ◽  
pp. 964-967
Author(s):  
Shu Hua Bai ◽  
Hai Dong Yang

Nowadays, energy crisis is becoming increasingly serious. Coal, petroleum, natural gas and other fossil energy tend to be exhausted due to the crazy exploration. In recent decades, several long lasting local wars broke out in large scale in Mideast and North Africa because of the fighting for the limited petroleum. The reusable green energy in our life like enormous wind power, solar power, etc is to become the essential energy. This article is to conduct a comparative exploration of mini wind turbine, with the purpose of finding a good way to effectively deal with the energy crisis.