scholarly journals Efficient and affordable thermomagnetic materials for harvesting low grade waste heat

APL Materials ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 011105
Author(s):  
Daniel Dzekan ◽  
Anja Waske ◽  
Kornelius Nielsch ◽  
Sebastian Fähler
Keyword(s):  
1992 ◽  
Vol 25 (12) ◽  
pp. 33-47 ◽  
Author(s):  
T. S. C. Gross ◽  
R. R. Cohen

The small island of Jersey is served by a single wastewater treatment plant at Bellozanne. Since its inception some 30 years ago the sludge produced has been used on agricultural land. Inevitably there are circumstances which prevent this happening without interruption, eg, poor weather, or seasonal demand. On these occasions, the island has no other disposal option to fall back on. Furthermore, concerns over the practice have created a perception that it might be doing harm to the ‘quality' of the farm produce. The responsible body, the Public Services Department, formulated a flexible, multiple option solution and commissioned Halcrow to engineer the capital works. The works centre around a thermal drying plant using biogas produced by the digestion process as the main fuel. Waste heat is recovered for digester heating making the total process potentially self sufficient in energy. At the same time, the bulk of the product is reduced considerably, providing an easily transported material with potential for use directly on the land as a fertilizer substitute or as a low grade fuel. Farfrom being a disposal problem requiring manpower and expense, sludge will soon be regarded by the States of Jersey as a valuable resource with a revenue potential.


Author(s):  
Noman Yousuf ◽  
Timothy Anderson ◽  
Roy Nates

Abstract Despite being identified nearly a century ago, the diffusion absorption refrigeration (DAR) cycle has received relatively little attention. One of the strongest attractions of the DAR cycle lies in the fact that it is thermally driven and does not require high value work. This makes it a prime candidate for harnessing low grade heat from solar collectors, or the waste heat from stationary generators, to produce cooling. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. In this vein, this work developed a new parametric model that can be used to examine the performance of the DAR cycle for a range of operating conditions. The results showed that the cycle's performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flowrate of the refrigerant and the type of the working fluid. It was shown that can deliver good performance at low generator temperatures if the refrigerant mass fraction in the strong solution is made as high as possible. Moreover, it was shown that a H2O-LiBr working pair could be useful for achieving cooling at low generator temperatures.


Author(s):  
James F. Walton ◽  
Andrew Hunsberger ◽  
Hooshang Heshmat

In this paper the authors will present the design and preliminary test results for a distributed electric generating system that uses renewable energy source for economical load-following and peak-shaving capability in an oil-free, high-speed micro-turboalternator system using compliant foil bearings and a permanent magnet alternator. Test results achieved with the prototype system operating to full speed and under power generating mode will be presented. A comparison between predicted and measured electrical output will also be presented up to a power generating level of 25 kWe at approximately 55,000 rpm. The excellent correlation between design and test provides the basis for scale up to larger power levels. Based upon the turboalternator test results a thermodynamic cycle analysis of a system using low grade waste heat water at approximately 100 C will be reviewed. The tradeoff study results for a series of environmentally friendly refrigerant working fluids will also be presented including sensitivity to vaporization and condensing temperatures. Based on the cycle and pinch point analyses predicted maximum output power was determined. Finally a preliminary turbine design for the selected R134a working fluid was completed. The results of this study show that a net output power level of greater than 40 kW is possible for approximately 240 l/m flow of water at 100C is possible.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2574 ◽  
Author(s):  
Ramadas Narayanan ◽  
Edward Halawa ◽  
Sanjeev Jain

Air conditioning accounts for up to 50% of energy use in buildings. Increased air-conditioning-system installations not only increase total energy consumption but also raise peak load demand. Desiccant evaporative cooling systems use low-grade thermal energy, such as solar energy and waste heat, instead of electricity to provide thermal comfort. This system can potentially lead to significant energy saving, reduction in carbon emissions, and it has a low dew-point operation and large capacity range. Their light weight, simplicity of design, and close-to-atmospheric operation make them easy to maintain. This paper evaluates the applicability of this technology to the climatic conditions of Brisbane, Queensland, Australia, specifically for the residential sector. Given the subtropical climate of Brisbane, where humidity levels are not excessively high during cooling periods, the numerical study shows that such a system can be a potential alternative to conventional compression-based air-conditioning systems. Nevertheless, the installation of such a system in Brisbane’s climate zone requires careful design, proper selection of components, and a cheap heat source for regeneration. The paper also discusses the economy-cycle options for this system in such a climate and compares its effectiveness to natural ventilation.


Sign in / Sign up

Export Citation Format

Share Document