In-situ sampling of soil pore water: evaluation of linear-type microdialysis probes and suction cups at varied moisture contents

2010 ◽  
Vol 7 (1) ◽  
pp. 123 ◽  
Author(s):  
Manuel Miró ◽  
Walter J. Fitz ◽  
Siegfried Swoboda ◽  
Walter W. Wenzel

Environmental context. There is a need for slightly invasive techniques capable of in-situ probing of target analytes in environmental compartments. Owing to its passive sampling mode and small probe dimensions, microdialysis-based dosimetry is an appealing tool for monitoring of solute concentrations in both water bodies and pore soil waters with minimum disturbance of natural equilibrium. The development of field applications is challenging but will provide novel insights as to the speciation and bioaccessibility of environmental pollutants, e.g. trace metals, at high spatial resolution. Abstract. In-situ sampling of soil pore water is still a challenge for environmental scientists. Here, microdialysis is explored for probing metal concentrations in soil pore water at soil moisture contents ranging from 50 to 115% of the maximal water holding capacity and is compared with traditional sampling by suction cups. Metal concentrations obtained by the suction cup technique were consistently larger than those measured in the dialysate. Good agreement was obtained for Pb and Cu at soil moistures close to saturation after accounting for diffusion resistances whereas corrected Ni and Cd concentrations in the dialysates exceeded those measured by the suction cup technique. These deviations reflect inherent differences in the sampling mode and effects of soil heterogeneity at the microscale. Microdialysis offers new opportunities to probe solute concentrations at high spatial resolution and minimal disturbance of soil conditions at environmental interfaces such as the plant rhizosphere or at the transition between forest floors and the mineral soil.

2012 ◽  
Vol 49 ◽  
pp. 18-26 ◽  
Author(s):  
Sami Ullah ◽  
Hao Zhang ◽  
A. Louise Heathwaite ◽  
Andrew Binley ◽  
Katrina Lansdown ◽  
...  

2013 ◽  
Vol 15 (11) ◽  
pp. 2023 ◽  
Author(s):  
Zachary M. Payne ◽  
Krishna M. Lamichhane ◽  
Roger W. Babcock ◽  
Stephen J. Turnbull

2017 ◽  
Vol 32 (5) ◽  
pp. 975-986 ◽  
Author(s):  
Lie-Wen Xie ◽  
Jin-Hui Yang ◽  
Qing-Zhu Yin ◽  
Yue-Heng Yang ◽  
Jing-Bo Liu ◽  
...  

A new LA-MIC-ICP-MS analytical technique has been developed for the rapid measurement of 206Pb/238U zircon age (<1%, 2s) at a high spatial resolution. We show that this technique can be routinely employed to date U–Pb in small and/or complex zircons, providing a powerful tool for geochronology.


2013 ◽  
Vol 6 (3) ◽  
pp. 4183-4221 ◽  
Author(s):  
J. Henneberger ◽  
J. P. Fugal ◽  
O. Stetzer ◽  
U. Lohmann

Abstract. Measurements of the microphysical properties of mixed-phase clouds with high spatial resolution are important to understand the processes inside these clouds. This work describes the design and characterization of the newly developed ground-based field instrument HOLIMO II (HOLographic Imager for Microscopic Objects II). HOLIMO II uses digital in-line holography to in-situ image cloud particles in a well defined sample volume. By an automated algorithm, two-dimensional images of single cloud particles between 6 and 250 μm in diameter are obtained and the size spectrum, the concentration and water content of clouds are calculated. By testing the sizing algorithm with monosized beads a systematic overestimation near the resolution limit was found, which has been used to correct the measurements. Field measurements from the high altitude research station Jungfraujoch, Switzerland, are presented. The measured number size distributions are in good agreement with parallel measurements by a fog monitor (FM-100, DMT, Boulder USA). The field data shows that HOLIMO II is capable of measuring the number size distribution with a high spatial resolution and determines ice crystal shape, thus providing a method of quantifying variations in microphysical properties. A case study over a period of 8 h has been analyzed, exploring the transition from a liquid to a mixed-phase cloud, which is the longest observation of a cloud with a holographic device. During the measurement period, the cloud does not completely glaciate, contradicting earlier assumptions of the dominance of the Wegener–Bergeron–Findeisen (WBF) process.


2022 ◽  
Vol 17 (1) ◽  
Author(s):  
Chien-Ping Wang ◽  
Burn Jeng Lin ◽  
Pin-Jiun Wu ◽  
Jiaw-Ren Shih ◽  
Yue-Der Chih ◽  
...  

AbstractAn on-wafer micro-detector for in situ EUV (wavelength of 13.5 nm) detection featuring FinFET CMOS compatibility, 1 T pixel and battery-less sensing is demonstrated. Moreover, the detection results can be written in the in-pixel storage node for days, enabling off-line and non-destructive reading. The high spatial resolution micro-detectors can be used to extract the actual parameters of the incident EUV on wafers, including light intensity, exposure time and energy, key to optimization of lithographic processes in 5 nm FinFET technology and beyond.


2014 ◽  
Vol 36 (12) ◽  
pp. 2012-2015 ◽  
Author(s):  
Ren Arita ◽  
Tomoharu Nakazato ◽  
Toshihiko Shimizu ◽  
Kohei Yamanoi ◽  
Melvin John Fernandez Empizo ◽  
...  

2013 ◽  
Vol 5 (10) ◽  
pp. 5064-5088 ◽  
Author(s):  
Roberto Chávez ◽  
Jan Clevers ◽  
Martin Herold ◽  
Edmundo Acevedo ◽  
Mauricio Ortiz

Sign in / Sign up

Export Citation Format

Share Document